Fluke 116 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 116 manuals!
Problems with Fluke 116?

Ask a Question

Most Recent Fluke 116 Questions

How To Zero Ohm Out
when in ohm scale and touch end of leads together not getting zero . Have tried different leads but ...
(Posted by unklare 2 years ago)

Fluke 116 Videos

How to use a Fluke 116 HVAC Meter Cooling and Heating
Duration: 6:50
Total Views: 179
How to use a Fluke 116 HVAC Meter EN
Duration: 6:36
Total Views: 1
Fluke 116 HVAC Multimeter with Temperature and Microamps
Duration: 1:01
Total Views: 5,524
PDI DM-918 Vs Fluke 116
Duration: 2:59
Total Views: 1,416

Popular Fluke 116 Manual Pages

Fluke 116 Digital Multimeter Datasheet - Page 1

...; CAT III 600 V safety rated General specifications Accuracy is specified for the HVAC professional. Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between...
Fluke 116 Digital Multimeter Datasheet - Page 2

...-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other true-rms meters to 5 kHz for ac current.  Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and 9V battery (installed).
Fluke 116 Users Manual - Page 1

® 116 True-rms Multimeter Users Manual PN 2538688 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation. Printed in China All product names are trademarks of their respective companies. All rights reserved.
Fluke 116 Users Manual - Page 3

True-rms Multimeter Introduction The Fluke Model 116, is unspecified. 1 Register your Meter at www.fluke.com. Unsafe Voltage To alert you to the presence of danger from transient impulses. When making frequency measurements >1 kHz, the Y symbol is a battery-powered, true-rms multimeter (hereafter "the Meter") with a 6000-count display and a bar graph. The IEC 61010-1 2nd Edition safety...
Fluke 116 Users Manual - Page 5

Contact Fluke or a qualified recycler for continuity before use the Auto Volts function to manual J Earth ground D AC and DC ~ Do...Double Insulated X Hazardous voltage W Important Information; True-rms Multimeter Safety Information • Comply with local and national safety requirements when working alone. • Use only the replacement fuse specified or the protection may be damaged ...
Fluke 116 Users Manual - Page 7

True-rms Multimeter Display No. I DC AC Direct current or alternating current J N Battery low warning. L (Bar graph) Analog display. M Auto Volts The Meter is selected. 5 The Meter selects the range for the selected range. User sets the Meter's range. N + Bar graph polarity O 0L W The input is measuring voltage or capacitiance with a low input impedance. P 0PEn ...
Fluke 116 Users Manual - Page 8

... error. 116 Users Manual Terminals COM + 2 1 edy01f.eps No. The Meter must be repaired before the Meter will operate. 6 Description A Common (return) terminal for measuring voltage, continuity, resistance, capacitance, frequency, temperature, microamps and testing diodes.. Calibration required. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced...
Fluke 116 Users Manual - Page 9

... true-rms. AC voltage is ac-coupled. True-rms Multimeter Rotary Switch Positions Rotary Switch Positions Switch Position Measurement Function x e Hz (button) Automatically selects ac or dc volts based on at 250 Ω. l AC voltage from 0.1 Ω to 600 mV, dc-coupled. AC current from 5 Hz to 600 μA. Frequency from 6.0 to 50 kHz. y Temperature from...
Fluke 116 Users Manual - Page 11

... show how to Autorange and Auto is displayed when enabled. True-rms Multimeter Power-Up Options Power-Up Options are canceled when you press qwhile in the MIN MAX AVG or Display HOLD modes. The Meter returns to make basic measurements. Note You cannot manually change the range in MIN MAX AVG or Display Hold...
Fluke 116 Users Manual - Page 13

This function also sets the Meter's input impedance to approximately 3 kΩ to reduce the possibility of false readings due to dc millivolts. 11 Press g to switch the Meter to ghost voltages. Measuring AC and DC Voltage Volts AC Volts DC V True-rms Multimeter Making Basic Measurements Measuring AC and DC Millivolts Millivolts AC Millivolts DC DC eeo03f...
Fluke 116 Users Manual - Page 15

Measuring Capacitance True-rms Multimeter Making Basic Measurements Measuring Temperature RANGE eeo05f.eps Vent or 80BK Type K Pipe Thermocouple Probe eeo10f.eps XW Warning To avoid risk of electric shock, do NOT connect 80BK to live circuits. 13
Fluke 116 Users Manual - Page 17

... measure currents that exceed the rating of the Meter. Testing Diodes Good Diode Good Diode True-rms Multimeter Making Low Impedance Capacitance Measurements Measuring Current above 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your local Fluke representative for your current...
Fluke 116 Users Manual - Page 19

..., until it from the Meter before opening the case or battery door. Lift the door straight up to separate it is then inserted into the case. 5. Cleaning Wipe the case with a damp cloth and mild detergent. Install and tighten battery door screw. Remove the battery door screw. 3. True-rms Multimeter Cleaning The battery fits inside...
Fluke 116 Users Manual - Page 21

True-rms Multimeter General Specifications IP Rating (dust and water protection IP42 Table 1. Accuracy Specifications Function DC millivolts DC Volts Range 600.0 mV 6.000 V 60.00 V 600.0 V Auto-V LoZ[1] True-rms 600.0 V AC millivolts[1] Truerms AC Volts[1] True-rms 600.0 mV 6.000 V 60.00 V 600.0 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.001 V 0.01 V 0.1 V Accuracy ± ...
Fluke 116 Users Manual - Page 23

True-rms Multimeter General Specifications Table 1 Accuracy Specifications (cont.) Function AC μAmps True-rms[1] (45 Hz to 1 kHz) Range 600...Temperature uncertainty (accuracy) does not include the error of ≤3 at 4000 counts, decreasing linearly to 50 kHz. 21 For volts and μA, crest factor of the thermocouple probe. [3] Frequency is normal for this and other true-rms meters...

Fluke 116 Reviews

Do you have an experience with the Fluke 116 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 116 Search Terms

The following terms are frequently used to search for Fluke 116 support:

Ask a New Question
Use the box below to post a new question about Fluke 116.
Manuals / Documents
Download any of our Fluke 116 manuals for free!

We have the following 2 documents available for the Fluke 116:
  • Fluke 116 Users Manual
  • Fluke 116 Digital Multimeter Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 116 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 116 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.