Get support for Fluke 115

Fluke 115 Support Question

Fluke 115 Support Question

Find answers below for this question about Fluke 115.
Need a Fluke 115 manual? We have 2 online manuals for this item!
Question posted by piyalr2021 on September 11th, 2022

Ohm Scale

ohms reading is wrong

Current Answers

Answer #1: Posted by SonuKumar on September 11th, 2022 8:05 AM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,620,300
1,100
points


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related Fluke 115 Manual Pages

Fluke 115 Digital Multimeter Datasheet - Page 1

... service technicians The Fluke 115 is specified for A ...28 °C, with relative humidity at operating temperatures of electrical and electronic testing applications. Features include: • Resistance, continuity, frequency, capacitance... accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge protection Fuse...
Fluke 115 Digital Multimeter Datasheet - Page 2

... ac current.  Fluke Corporation 115 Multimeter Ordering information Fluke-115 Multimeter Included TL75 Test leads, ...zero readings when the test leads are disconnected from 1 % to 1.5 at full scale.... V 0.1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 50 kHz for ac voltage. Ohms 600.0 Ω 0.1Ω 0.9 % + 2 6.000 kΩ 0.001 kΩ 60.00 kΩ 600.0 kΩ 0.01 k&#...
Fluke 114,115,117 Manual - Page 1

® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies.
Fluke 114,115,117 Manual - Page 3

... test leads are in an incorrect terminal. When making frequency measurements >1 kHz, the Y symbol is unspecified. True-rms Multimeters Introduction The Fluke Model 114, Model 115, and Model 117 are designed to IV) based on the magnitude of a potentially hazardous voltage, the Y symbol is displayed when the Meter measures a voltage ≥...
Fluke 114,115,117 Manual - Page 4

..., between terminals or between any terminal and earth ground. • Use caution with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could damage the Meter or the equipment under test.
Fluke 114,115,117 Manual - Page 6

... voltage detect mode. Measured input voltage ≥30 V, or voltage overload condition (OL). edy02f.eps Model 117 114, 115, & 117 115 & 117 114, 115, & 117 114, 115, & 117 The Meter function is set to Continuity. 114, 115, and 117 Users Manual Display No. A B C D E 4 Symbol w s R O Y 6 5 4 3 2 1 16 15 VoltAlert 7 14 17 8 9 10 11 12 13 18 Meaning...
Fluke 114,115,117 Manual - Page 7

... & 117 Auto Autoranging. Briefly displayed whenever the Meter's function switch is rotated to or from any A position. 115 & 117 5 Display freezes present reading. 114, 115, & 117 G M MIN MAX AVG mode enabled. The Meter selects the range for the selected range. 114, 115, & 117 R LEAd W Test lead alert. True-rms Multimeters Display F K Display hold enabled.
Fluke 114,115,117 Manual - Page 8

The Meter must be repaired before it will operate. Internal error. 114, 115, and 117 Users Manual Terminals 1 V A COM 3 10 A FUSED 2 No. B Common (.... Internal error. The Meter must be replaced before the Meter will operate. 6 edy01f.eps Model 115 & 117 114, 115, & 117 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err Error Messages Battery must be repaired before...
Fluke 114,115,117 Manual - Page 9

...to 600 V. DC current from 5 Hz to 40 MΩ. Non-contact sensing of ac voltage. 115 & 117 115 & 117 115 & 117 115 & 117 117 Note: All ac functions and Auto-V LoZ are dc-coupled. 7 Frequency from ...50 kHz. DC voltage from 0.1 to 600 mV. 114 & 117 114, 115 & 117 115 & 117 114, 115 & 117 114, 115 & 117 Ω Ohms from 45 Hz to 9999 μF. DC voltage from 1 nF to 5 kHz...
Fluke 114,115,117 Manual - Page 10

...the best resolution. • In the Manual Range mode, you apply a different voltage. 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks...displayed. • Press p to step through the low (MIN), average (AVG), and present readings. • To pause MIN MAX AVG recording without erasing stored values, press f. To disable the...
Fluke 114,115,117 Manual - Page 12

114, 115, and 117 Users Manual Measuring Resistance Testing for Continuity XWWarning edy04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power ...
Fluke 114,115,117 Manual - Page 14

... 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential ...
Fluke 114,115,117 Manual - Page 15

... for your current probe. Measuring Current above 10 Amps The millivolt and voltage function of the Meter. True-rms Multimeters Making Basic Measurements Measuring Capacitance (115 & 117 only) edy14f.eps edy05f.eps 13
Fluke 114,115,117 Manual - Page 16

... is >1 kHz, the bar graph and Z are unspecified. Frequency works with ac functions only. 114, 115, and 117 Users Manual Measuring Frequency (115 & 117 only) XWWarning To avoid electrical shock, disregard the bar graph for a stable reading. Detecting AC Voltage Presence (117 only) VoltAlert Hot Neutral VoltAlert RANGE Lo edy09f.eps The Meter...
Fluke 114,115,117 Manual - Page 17

... indication when voltage is recessed within the connector itself. Making Low Impedance Capacitance Measurements (115 & 117 only) For making capacitance measurements on cables with ghost voltage, hold qwhile ... switch the Meter into sleep mode. True-rms Multimeters Making Basic Measurements Testing Diodes (115 & 117) Good Diode Good Diode Forward Bias Single Beep Bad Diode Reverse Bias Bad...
Fluke 114,115,117 Manual - Page 18

Testing the Fuse (115 & 117 only) Test fuse as shown below ), the major divisions on the scale represent 0, 15, 30, 45, and 60 V. An input of −30 V ... kHz. The bar graph is relative to the full-scale value of the selected range. The number of segments indicates the measured value and is disabled when measuring capacitance. 114, 115, and 117 Users Manual Using the Bargraph The bar ...
Fluke 114,115,117 Manual - Page 20

... fuse having a minimum interrupt rating of 17,000 A. Dirt or moisture in the terminals can affect readings. 18 Separate the case bottom from the case bottom. 4. To re-assemble the Meter, first attach...window. Remove two screws from the case top. 5. Remove the fuse from the Meter 2. 114, 115, and 117 Users Manual To open the case for fuse replacement: 1. Remove the test leads from ...
Fluke 114,115,117 Manual - Page 22

114, 115, and 117 Users Manual Certifications UL, P, CSA, TÜV, ; (N10140),... V 60.00 V 600.0 V Auto-V LoZ[1] True-rms 600.0 V AC millivolts[1] Truerms AC Volts[1] True-rms 600.0 mV 6.000 V 60.00 V 600.0 V Resolution Accuracy ± ([% of Reading] + [Counts]) 0.1 mV 0.001 V 0.01 V 0.1 V 0.1 V 0.1 mV 0.5 % + 2 0.5 % + 2 DC, 45 to 500 Hz 2.0 % + 3 45 to 500 Hz 1.0 % + 3 500 Hz to 1 ...
Fluke 114,115,117 Manual - Page 23

detects opens or shorts of Reading] + [Counts]) Beeper on < 20 Ω, off > 250 Ω; Function Continuity Ohms Diode test Capacitance Lo-Z Capacitance (Power-up option) True-rms Multimeters ... 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 μF - 1000 μF: 1.9 % + 2 > 1000 μF: 5 % + 20 1 nF to 500 μF 10% + 2 typical Model 114, 115, 117 114, 115, 117 115, 117 115, 117 115, 117 21
Fluke 114,115,117 Manual - Page 24

... 22 For amps, crest factor of ≤3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is specified from 0.0 V. AutoV LoZ, AC mV, and AC amps are dc-coupled... from a circuit or are shorted together. 114, 115, and 117 Users Manual Table 1 Accuracy Specifications (cont.) Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model AC Amps Truerms[1] (45...

Similar Questions

Where Can I Get Fluke 115 Service Manual
(Posted by stevenedwardmorris 1 year ago)
How To Zero Ohm Out
when in ohm scale and touch end of leads together not getting zero . Have tried different leads but ...
(Posted by unklare 2 years ago)
My T5 Will Not Read Continuity ?
My t5 will not read continuity ? is there any adjustment? voltage reads fine, amps reads fine?
(Posted by juanalaniz 5 years ago)
No Reading On Amps
HiI have tried reading amps with the fluke 333 clamp on meter. All I get is 0 amps. It is working fi...
(Posted by donal3987 7 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 115 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.