Most Recent Fluke 52 Questions

Calibration Error
Cal Err
(Posted by vidya1356 1 year ago)
Fluke 116 No Fuese
why is there no fueses in a fluke 116
(Posted by johnoboy09 10 years ago)

Fluke 52 Videos

Fluke 52-2 Thermometer Series II At The Olympics
Duration: 2:54
Total Views: 582
Fluke at the Olympics - 52 Series II Contact Thermometer and Surface Probe
Duration: 2:49
Total Views: 1,753
P'Fluke @ RS - 04-10-52
Duration: 4:19
Total Views: 2,214
Paul Newman's Amazing Snooker Fluke 52
Duration: :10
Total Views: 17

Popular Fluke 52 Manual Pages

Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet - Page 1

... 2372°F) (32°F to 3212°F) ± [ 0.05% + 0.3°C (0.5°F) ] ± [ 0.05% + 0.4°C (0.7°F) ] ± [ 0.20% + 0.3°C (0.5°F) ] ± [ 0.50% + 0.3°C (0.5°F) ] **Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples. Wherever you go.
FE 51 & 52 II Users Manual - Page 1

Printed in USA All product names are trademarks of their respective companies. Users Manual ® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
FE 51 & 52 II Users Manual - Page 4

51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual - Page 5

...-0181 in Japan +65-738-5655 in Table 2. Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Otherwise, the protection provided by the meter may be impaired. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to : Fluke Corporation P.O. Use the thermometer only as temperature sensors.
FE 51 & 52 II Users Manual - Page 6

.... • Replace the batteries as soon as marked on the thermometer, between the thermocouple(s), or between any thermocouple and earth ground. 2 Protection may be impaired. Safety Information WWarning A Warning identifies conditions and actions that pose hazards to personal injury. • Do not use the thermometer if it operates abnormally. 51 & 52 Series II Users Manual Table 1.
FE 51 & 52 II Users Manual - Page 7

... WWarning (cont.) • Model 52: Measurement errors may damage the meter or the equipment under test. • Use the proper thermocouples, function, and range for your thermometer. • Do not attempt ... When servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with any part of the battery with the battery case. 3 51 & 52 Series II Introduction...
FE 51 & 52 II Users Manual - Page 8

... of the buttons. International Symbols W M Refer to Models 51 and 52 unless otherwise indicated. Battery. To become familiar with relevant Canadian Standards Association directives. Getting Started Everything in this Users Manual applies both to the manual for information about this feature. P Complies with European Union directives. 51 & 52 Series II Users Manual Table 2.
FE 51 & 52 II Users Manual - Page 10

...& 52 Series II Users Manual Display Elements 23 4 1 10 9 Figure 2. Display Elements A The thermocouple measurement includes an offset. D Setup is in progress. Model 51: T1 reading. Model 52: ...do not change. H Secondary Display: MAX, MIN, AVG, or offset. See "Changing Setup Options." Replace the batteries. Model 52: T1, T2, or T1-T2 reading. I The thermocouple type. C A shift function...
FE 51 & 52 II Users Manual - Page 12

... or exit Setup. (See "Changing Setup Options.") Press K to scroll to the Setup option you want to change . Press N to store the displayed setting in memory. 8 Press E again to decrease the displayed setting. Press N to scroll to the Setup option you want to change . Press E to increase the displayed setting. Press K to enter a Setup option. 51 & 52 Series II Users Manual...
FE 51 & 52 II Users Manual - Page 13

...the thermocouple type, offset, sleep mode, and line frequency settings. Setup settings reset only when the batteries are removed for more than 2 minutes. 51 & 52 Series II Using the Thermometer Entering or Exiting Setup When the thermometer is "open," the display shows "- - - -" Changing Setup Options Use Setup to start or exit Setup. Plug the thermocouple(s) into the selected input or the...
FE 51 & 52 II Users Manual - Page 14

... of line noise, the thermometer must be set for 20 minutes. Press E to use appears on the thermometer and is automatically disabled in MIN MAX mode. 51 & 52 Series II Users Manual Changing a Setup Option 1. Press K or N until the setting you change this setting. 3. Pressing any button wakes the thermometer and returns it is disabled in memory. Model 52: You can store individual...
FE 51 & 52 II Users Manual - Page 15

... display. 51 & 52 Series II Measuring Temperatures Notes The display shows "- - - -" when a thermocouple is outside the thermocouple's valid range. Set the thermometer for the correct thermocouple type. Hold or attach the thermocouple(s) to select the correct temperature scale. 2. The display shows 0L (overload) when the temperature being measured is not connected. Model 52: If only...
FE 51 & 52 II Users Manual - Page 16

.... 3. 51 & 52 Series II Users Manual Holding the Displayed Readings 1. The elapsed time since entering MIN MAX mode, or the time at which the minimum or maximum occurred, appears on the display. Plug the thermocouple into the input connector. 2. Using the Offset to Adjust for Probe Errors Use the offset option in Setup to adjust the thermometer's readings...
FE 51 & 52 II Users Manual - Page 17

... or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Replace the battery door and tighten the screw. To calibrate the thermometer, contact Fluke for the Service Center nearest you...
FE 51 & 52 II Users Manual - Page 19

...specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual..., or T1-T2 (Model 52) Temperature Coefficient Electromagnetic Compatibility...

Fluke 52 Reviews

Do you have an experience with the Fluke 52 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 52 Search Terms

The following terms are frequently used to search for Fluke 52 support:

Ask a New Question
Use the box below to post a new question about Fluke 52.
Manuals / Documents
Download any of our Fluke 52 manuals for free!

We have the following 2 documents available for the Fluke 52:
  • FE 51 & 52 II Users Manual
  • Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 52 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 52 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.