Fluke 83-5 Support and Manuals
Popular Fluke 83-5 Manual Pages
Manual - Page 1
All product names are subject to change without notice. Specifications are trademarks of their respective companies.
®
80 Series V
Multimeters
May 2004 Rev.2, 11/08 ©2004, 2008 Fluke Corporation. All rights reserved. Users Manual
Manual - Page 4
... Only 31 Uses for the Zoom Mode 31 HiRes Mode (Model 87 31 MIN MAX Recording Mode 32 Smooth Feature (Power Up Option Only 32 AutoHOLD Mode...34 Relative Mode ...34 Maintenance ...35 General Maintenance 35 Fuse Test ...35 Replacing the Battery 36 Replacing the Fuses 37 Service and Parts...37 Specifications...43 Detailed Specifications 44
ii
Manual - Page 5
... 47 14. Electrical Characteristics of Tables
Table
Title
Page
1. Replacement Parts ...39 9. Accessories ...42 10. Inputs...6 3. Current Function Specifications 48 15. List of the Terminals 51 19. Model 83 AC Voltage Function Specifications 45 12. Rotary Switch Positions ...7 4. Frequency Counter Specifications 49 17. Display Features...11 6. Capacitance and Diode...
Manual - Page 9
...) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in all illustrations.
Introduction
XW Warning
Read "Safety Information" before you use the Meter. Except where noted, the descriptions and instructions in this manual apply to Series V Models 83 and 87 multimeters (hereafter referred to...
Manual - Page 11
...
• When servicing the Meter, use only specified replacement parts.
• When...is indicated may be present. Multimeters Safety Information
• When making...serviced.
• Do not operate the Meter around explosive gas, vapor, or dust.
• Use only a single 9 V battery, properly installed....
• Use only the replacement fuses specified by the manual.
• Use the proper ...
Manual - Page 13
See Manual.
Important information. Underwriters Laboratories
CAT IV
IEC Overvoltage Category IV
CAT IV equipment is designed to protect against transients in equipment in large buildings. G Diode
Inspected and licensed by TÜV Product Services.
5
Low battery when displayed.
Continuity test or continuity beeper tone.
$
Conforms to European Union directives. Multimeters ...
Manual - Page 34
...power to the circuit;
If you are using the mA/μA terminal, set up correctly, test the Meter's fuses as described under "Testing the ...be tested. If you are using the values listed in the specifications in Table 14.
26 Reversing the leads will produce a ...display. Touch the black probe to mA/A. 80 Series V Users Manual
3. To measure dc current, press A.
5. touch the red...
Manual - Page 40
Model 83 has 100 millisecond response time; The 100 millisecond response time is best for smoothing out unstable inputs, calculating power consumption... extremes lasting longer than 100 ms.
Peak records the signal extremes lasting longer than 250 µs. 80 Series V Users Manual
MIN MAX Recording Mode
The MIN MAX mode records minimum and maximum input values.
MIN MAX mode can be recorded.
Manual - Page 43
...
XW Warning
To avoid possible electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel as follows:
1. General Maintenance
Periodically wipe the case with a cleaning and oiling agent (such as shown in the terminals.
3. Multimeters Maintenance
Fuse Test
If a test lead is plugged into...
Manual - Page 45
... accessories, refer to Figure 11, examine or replace the Meter's fuses as follows:
1. Replacing the Fuses
Referring to "Contacting Fluke".
37 Remove the three Phillips-head screws from the terminals.
2. Install ONLY specified replacement fuses with the amperage, voltage, and speed ratings shown in the OFF position.
8. Multimeters Service and Parts
7.
Gently push up the input terminal-end...
Manual - Page 52
...; C, with relative humidity up to 13 digits with leads shorted, will cause only a 2-digit change for a period of one year after calibration. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a crest factor up to 90 %, for readings over 3 % of range. Model 87 AC Voltage Function Specifications
Function Range Resolution
Accuracy
K [2,4]
600.0 mV...
Manual - Page 53
Model 83 AC Voltage Function Specifications
Function
Range
Resolution
K1
600.0 mV 0.1 mV
6.000 V
0....% + 2) ± (0.5 % + 2)
Accuracy
30 Hz - 1 kHz ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4) ± (1.0 % + 4)
Multimeters Specifications
1 kHz - 5 kHz ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4) ± (2.0 % + 4)2 unspecified
45 Table 11.
Manual - Page 54
DC Voltage, Resistance, and Conductance Function Specifications
Function
Range
Resolution
Model 83
Accuracy
Model 87
6.000 V
0.001 V
± (0.1 % + 1)
± (0.05 % + 1)
L
60.00 V
0.01 V
± (0.1 % + 1)
± (0.05 % + 1)
600.0 V
0.1 V
± (0.1 % + 1)
± (0.05 % + 1)
1000 ... Users Manual
Table 12. When using the REL Δ function to compensate for offsets. 2.
Datasheet - Page 1
...-solving power, safety, convenience and impact protection. 80 Series V Industrial True-RMS Multimeter
with Temperature
Accuracy and diagnostic functions for maximum industrial productivity
The new Fluke 87V has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on adjustable speed motor drives and other electrically noisy equipment (87V...
Datasheet - Page 2
A. 87V Industrial Multimeter
B. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more than $50* compared with TL75 Test Leads, AC72 Alligator Clips, holster, 9 V battery (installed), temperature probe (87V only) CD-ROM (user's manual and technical notes) and operator's guide.
Removable test probes with Temperature Fluke-87-5/E2 Industrial Electrician Combo Kit
Fluke. Keeping ...