Information Update - Power Infrastructure Sizing
Page 1
... to avoid costly over-provisioning, you need to understand how to assess power consumption of the system to the workload expected of Power Distribution Units (PDUs), Uninterruptible Power Supplies (UPSs), and other power infrastructure distribution equipment. On-line capacity planning tools available from Dell system management software provide additional predictability for a specific deployment, the assessment may...
... to avoid costly over-provisioning, you need to understand how to assess power consumption of the system to the workload expected of Power Distribution Units (PDUs), Uninterruptible Power Supplies (UPSs), and other power infrastructure distribution equipment. On-line capacity planning tools available from Dell system management software provide additional predictability for a specific deployment, the assessment may...
Dell PowerEdge M1000e Configuration Guide
Page 13
A module that is powered off or booting is indicated by a gray rectangle. If a module has errors, it is designated by an amber rectangle. - Enclosure Menu The Enclosure Menu includes ... status of the module and any errors present. • In the Enclosure Status dialog box, you can view the enclosure status, any error conditions, and power consumption statistics. • The Network Summary screen lists the IP addresses for Module Status, Enclosure Status, and Network Summary. • In the Module Status dialog box...
A module that is powered off or booting is indicated by a gray rectangle. If a module has errors, it is designated by an amber rectangle. - Enclosure Menu The Enclosure Menu includes ... status of the module and any errors present. • In the Enclosure Status dialog box, you can view the enclosure status, any error conditions, and power consumption statistics. • The Network Summary screen lists the IP addresses for Module Status, Enclosure Status, and Network Summary. • In the Module Status dialog box...
Dell PowerEdge M1000e Configuration Guide
Page 35
... on the CMC, as outlined in the enclosure and your needs. 6 Click Apply to save your changes. Configuring Power Budget and Redundancy The CMC's power management service optimizes power consumption for redundant CMC deployments. Installing or Updating the CMC Firmware NOTE: It is normal for some or all of the fan units to do...
... on the CMC, as outlined in the enclosure and your needs. 6 Click Apply to save your changes. Configuring Power Budget and Redundancy The CMC's power management service optimizes power consumption for redundant CMC deployments. Installing or Updating the CMC Firmware NOTE: It is normal for some or all of the fan units to do...
Hardware Owner's Manual
Page 19
...Status information screens for the modules installed in the back of the enclosure, including the IO modules, fans, CMC, iKVM, and power supplies. • A network summary screen listing the IP addresses of all components in the enclosure. LCD Module Features The primary ... on the health and status of the modules in the system. • Real time power consumption statistics, including high and low values, and average power consumption. • Ambient temperature values. • AC power information • Critical failure alerts and warnings. LCD module features include: • A...
...Status information screens for the modules installed in the back of the enclosure, including the IO modules, fans, CMC, iKVM, and power supplies. • A network summary screen listing the IP addresses of all components in the enclosure. LCD Module Features The primary ... on the health and status of the modules in the system. • Real time power consumption statistics, including high and low values, and average power consumption. • Ambient temperature values. • AC power information • Critical failure alerts and warnings. LCD module features include: • A...
Hardware Owner's Manual
Page 21
If a module has errors, it is indicated by a gray rectangle. If a blade has errors, this menu. A module that is powered off or booting is designated by an amber rectangle. • To select a blade, highlight it and press the center button. If a module is designated by a ... or booting is selected, a dialog box displays the current status of the blade and any error conditions, and power consumption statistics. • The Network Summary screen lists the IP addresses for the LCD menu screens using the arrow keys, and view its status. - Main Menu ...
If a module has errors, it is indicated by a gray rectangle. If a blade has errors, this menu. A module that is powered off or booting is designated by an amber rectangle. • To select a blade, highlight it and press the center button. If a module is designated by a ... or booting is selected, a dialog box displays the current status of the blade and any error conditions, and power consumption statistics. • The Network Summary screen lists the IP addresses for the LCD menu screens using the arrow keys, and view its status. - Main Menu ...
Hardware Owner's Manual
Page 45
...reports real-time power consumption, which includes logging high and low points with a time stamp. Network interface controller activity indicator Off Amber blinking LAN is linked. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Table...Network interface controller link indicator Off Green LAN is being identified by the systems (blinking) management software. Power indicator Off CMC does not have power. Blue The CMC is not linked. Fault indicator Off The CMC is the standby CMC. Serial ...
...reports real-time power consumption, which includes logging high and low points with a time stamp. Network interface controller activity indicator Off Amber blinking LAN is linked. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Table...Network interface controller link indicator Off Green LAN is being identified by the systems (blinking) management software. Power indicator Off CMC does not have power. Blue The CMC is not linked. Fault indicator Off The CMC is the standby CMC. Serial ...
Hardware Owner's Manual
Page 107
... Card" on page 217. For more than 250 W. Blade Messages (continued) Message Causes Corrective Actions Current Overlimit detected in the Internal Storage slot! not have power consumption more information, see "Expansion Card Installation Guidelines" on page 259. NOTE: Applicable to M610x only. card. PCIe card inserted in the dedicated slot. About Your...
... Card" on page 217. For more than 250 W. Blade Messages (continued) Message Causes Corrective Actions Current Overlimit detected in the Internal Storage slot! not have power consumption more information, see "Expansion Card Installation Guidelines" on page 259. NOTE: Applicable to M610x only. card. PCIe card inserted in the dedicated slot. About Your...
Hardware Owner's Manual
Page 217
...the card with the three screws. 4 Tighten the screws to secure the card to 250 W. Expansion Cards and Expansion-Card Riser (PowerEdge M610x Only) Expansion Card Installation Guidelines Your system supports up to the system board. Installing Blade Components 217 See "Installing a Blade... expansion slots are x16 connectors. • Do not install an expansion card in slot 2 if a double-width card is installed, it can have a power consumption of up to two Generation 2 PCIe expansion cards installed in slot 1. See "Removing a Blade" on page 159. 6 Install the blade. See Figure ...
...the card with the three screws. 4 Tighten the screws to secure the card to 250 W. Expansion Cards and Expansion-Card Riser (PowerEdge M610x Only) Expansion Card Installation Guidelines Your system supports up to the system board. Installing Blade Components 217 See "Installing a Blade... expansion slots are x16 connectors. • Do not install an expansion card in slot 2 if a double-width card is installed, it can have a power consumption of up to two Generation 2 PCIe expansion cards installed in slot 1. See "Removing a Blade" on page 159. 6 Install the blade. See Figure ...
Hardware Owner's Manual
Page 265
... cooling to configure the power budget, redundancy, and dynamic power of the entire enclosure (chassis, servers, I/O modules, iKVM, CMC, and power supplies). The power management service optimizes power consumption and re-allocates power to three power supply modules fail. Power Supply Modules The M1000e enclosure supports up to ... if an internal fan failure occurs. The power supplies are plugged into 110 V electrical outlets, the system provides 2200 W AC input power if you select the Allow 110 VAC Operation check box in the Dell Chassis Management Controller User's Guide. You can...
... cooling to configure the power budget, redundancy, and dynamic power of the entire enclosure (chassis, servers, I/O modules, iKVM, CMC, and power supplies). The power management service optimizes power consumption and re-allocates power to three power supply modules fail. Power Supply Modules The M1000e enclosure supports up to ... if an internal fan failure occurs. The power supplies are plugged into 110 V electrical outlets, the system provides 2200 W AC input power if you select the Allow 110 VAC Operation check box in the Dell Chassis Management Controller User's Guide. You can...
Dell M8428-k Hardware Reference Manual
Page 41
..., Enhanced Group Management, Fabric Watch, Advanced Zoning, ISL Trunking, Advanced Performance Monitoring, Data Center Fabric Manager (DCFM) Dell M8428-k Hardware Reference Manual 29 53-1001980-01 TABLE 8 Electrical specifications and requirements Dimension Measurements DC input Power consumption 12 V and 3.3 V from chassis About 60 W normally and 70 W maximum measured Architectural specification The switch module...
..., Enhanced Group Management, Fabric Watch, Advanced Zoning, ISL Trunking, Advanced Performance Monitoring, Data Center Fabric Manager (DCFM) Dell M8428-k Hardware Reference Manual 29 53-1001980-01 TABLE 8 Electrical specifications and requirements Dimension Measurements DC input Power consumption 12 V and 3.3 V from chassis About 60 W normally and 70 W maximum measured Architectural specification The switch module...
Fabric OS Command Reference Manual Supporting Fabric
Page 142
...Date of the last FRU header update: Update: Day: dd Month: mm Year: yyyy 9 Cumulative time, in days, that may be available. Power Consume Factor: -xxx 5 Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx 6 Serial number (up to inventory and ...(control processor), WWN (world wide name), or UNKNOWN. 2 chassisShow chassisShow Displays all field replaceable units (FRUs). Refer to calculate the object's power consumption: positive for power supplies and negative for consumers. If the FRU is no data set, these cases, the lines are 1, 3 through 7, 9, and 11...
...Date of the last FRU header update: Update: Day: dd Month: mm Year: yyyy 9 Cumulative time, in days, that may be available. Power Consume Factor: -xxx 5 Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx 6 Serial number (up to inventory and ...(control processor), WWN (world wide name), or UNKNOWN. 2 chassisShow chassisShow Displays all field replaceable units (FRUs). Refer to calculate the object's power consumption: positive for power supplies and negative for consumers. If the FRU is no data set, these cases, the lines are 1, 3 through 7, 9, and 11...
Fabric OS Command Reference Manual Supporting Fabric
Page 910
... execution of this command is included but not listed. • Total alternating current (AC) power consumption in Watts. • AC efficiency, as one of total and BTU. • Power efficiency in Watts/port and Watts/Gb. -m In addition to an incompatibility between the FOS... is empty. 2 slotShow Status Displays the status of the blade as a percentage of the following information about power consumption: • Total direct current (DC) power consumption for the chassis and individual values for each blade. 878 Fabric OS Command Reference 53-1001764-02 FAULTY The ...
... execution of this command is included but not listed. • Total alternating current (AC) power consumption in Watts. • AC efficiency, as one of total and BTU. • Power efficiency in Watts/port and Watts/Gb. -m In addition to an incompatibility between the FOS... is empty. 2 slotShow Status Displays the status of the blade as a percentage of the following information about power consumption: • Total direct current (DC) power consumption for the chassis and individual values for each blade. 878 Fabric OS Command Reference 53-1001764-02 FAULTY The ...
Fabric OS Command Reference Manual Supporting Fabric
Page 911
...BLADE 33 LOADING 11 SW BLADE 55 DIAG RUNNING POST1 12 SW BLADE 51 INSERTED, NOT POWERED ON 1 To display power consumption information: switch:user> slotshow -p Slot Blade Type ID DC Power Status Consumption 1 SW BLADE 77 130 ENABLED 2 SW BLADE 51 115 ENABLED 3 CORE BLADE 46... 60 ENABLED 7 AP BLADE 74 250 ENABLED 8 AP BLADE 74 250 FAULTY (21) Total DC Power Consumption: 1199 watts Total AC Power Consumption: 1332 watts AC @ 90% efficiency (4546 BTU) Power Efficiency: 1.04 watts per port, 0.26 watts per Gb To display Brocade model names for each ...
...BLADE 33 LOADING 11 SW BLADE 55 DIAG RUNNING POST1 12 SW BLADE 51 INSERTED, NOT POWERED ON 1 To display power consumption information: switch:user> slotshow -p Slot Blade Type ID DC Power Status Consumption 1 SW BLADE 77 130 ENABLED 2 SW BLADE 51 115 ENABLED 3 CORE BLADE 46... 60 ENABLED 7 AP BLADE 74 250 ENABLED 8 AP BLADE 74 250 FAULTY (21) Total DC Power Consumption: 1199 watts Total AC Power Consumption: 1332 watts AC @ 90% efficiency (4546 BTU) Power Efficiency: 1.04 watts per port, 0.26 watts per Gb To display Brocade model names for each ...
Technical Guide
Page 3
... Amps 33 5.7 Power-Up Sequence 33 5.8 Acoustics 33 6 Processors and Memory 35 7 Midplane...36 8 Embedded NICs/LAN on Motherboard (LOM 39 9 I/O ...40 9.1 Overview 40 9.2 Quantities and Priorities 41 9.3 Supported Mezzanine Cards and Switches 44 9.4 I/O Module Installation 45 9.5 FlexAddress 45 10 Storage ...51 11 Video...52 12 Rack Information 53 PowerEdge M1000e Technical Guide 2
... Amps 33 5.7 Power-Up Sequence 33 5.8 Acoustics 33 6 Processors and Memory 35 7 Midplane...36 8 Embedded NICs/LAN on Motherboard (LOM 39 9 I/O ...40 9.1 Overview 40 9.2 Quantities and Priorities 41 9.3 Supported Mezzanine Cards and Switches 44 9.4 I/O Module Installation 45 9.5 FlexAddress 45 10 Storage ...51 11 Video...52 12 Rack Information 53 PowerEdge M1000e Technical Guide 2
Technical Guide
Page 7
...as can be seen from 0. (Darker blue shading indicates increased memory density.) Table 2. PowerEdge M1000e Technical Guide 6 Rack vs. Dell Greater density means: • Smaller Footprint • More Processing Performance • More RAM capacity • Lower Power Consumption per 42U rack Intel 2 252 3 378 168 252 504 151 25 R610 Rack R710...38 9 6 M910 Full Blade Intel 4 1,024 16 640 256 64 38 9 6 1 This rack-level physical capacity specification summary does not factor in power and cooling. 2 42U is the most common rack size. 3 Storage measurements provided in Terabytes.
...as can be seen from 0. (Darker blue shading indicates increased memory density.) Table 2. PowerEdge M1000e Technical Guide 6 Rack vs. Dell Greater density means: • Smaller Footprint • More Processing Performance • More RAM capacity • Lower Power Consumption per 42U rack Intel 2 252 3 378 168 252 504 151 25 R610 Rack R710...38 9 6 M910 Full Blade Intel 4 1,024 16 640 256 64 38 9 6 1 This rack-level physical capacity specification summary does not factor in power and cooling. 2 42U is the most common rack size. 3 Storage measurements provided in Terabytes.
Technical Guide
Page 25
... average power consumption • Ambient temperature values • AC power information • Critical failure alerts and warnings See the M1000e Configuration Guide and the CMC Administrator Reference Guide for more details on the health and status of the modules in the rack. LCD Panel Capabilities The primary function of the LCD control panel. Dell information... in the enclosure. Figure 20. The LCD panel can be retracted into the chassis body, or extended and angled once deployed for CMC, iDRAC, and I/O PowerEdge M1000e Technical Guide 24
... average power consumption • Ambient temperature values • AC power information • Critical failure alerts and warnings See the M1000e Configuration Guide and the CMC Administrator Reference Guide for more details on the health and status of the modules in the rack. LCD Panel Capabilities The primary function of the LCD control panel. Dell information... in the enclosure. Figure 20. The LCD panel can be retracted into the chassis body, or extended and angled once deployed for CMC, iDRAC, and I/O PowerEdge M1000e Technical Guide 24
Technical Guide
Page 30
... M1000e power supplies continuously monitor AC input current, voltage and power, enabling exposure of data to Dell™ OpenManage™ IT Assistant or to any server module powering up, through any power optimization mode, should conditions warrant the activation of power from the system level, based upon its instantaneous power consumption never exceeds the budgeted amount. PowerEdge M1000e Technical Guide 29 Power...
... M1000e power supplies continuously monitor AC input current, voltage and power, enabling exposure of data to Dell™ OpenManage™ IT Assistant or to any server module powering up, through any power optimization mode, should conditions warrant the activation of power from the system level, based upon its instantaneous power consumption never exceeds the budgeted amount. PowerEdge M1000e Technical Guide 29 Power...
Technical Guide
Page 31
... VMware® products include consuming the "current power consumption" and "current power cap/limit" retrieval via Dell specific IPMI commands using this as the work output PowerEdge M1000e Technical Guide 30 The Power Management chapter in the Dell Chassis Management Controller (CMC) User Guide provides extensive information on power management. 5.2 Power Supply Specifications Each power supply offers: • 91%+ AC/DC...
... VMware® products include consuming the "current power consumption" and "current power cap/limit" retrieval via Dell specific IPMI commands using this as the work output PowerEdge M1000e Technical Guide 30 The Power Management chapter in the Dell Chassis Management Controller (CMC) User Guide provides extensive information on power management. 5.2 Power Supply Specifications Each power supply offers: • 91%+ AC/DC...
Technical Guide
Page 34
...of airflow required on support.dell.com. 5.5 Power Consumption Use the Dell Energy Smart Solution Advisor (ESSA) to boot and power up . 8. All six PSUs are powered up . 9. iKVM is powered up the power supply units. 3. Depending upon Blade BIOS power setting (last power state, always on the...control the fans as passive requirements due to choose the lowest fan speeds and PowerEdge M1000e Technical Guide 33 This request is engineered for the Dell M1000e Modular Server Enclosure - The first power supply provides a small amount of the fan behavior. Each one is optimized ...
...of airflow required on support.dell.com. 5.5 Power Consumption Use the Dell Energy Smart Solution Advisor (ESSA) to boot and power up . 8. All six PSUs are powered up . 9. iKVM is powered up the power supply units. 3. Depending upon Blade BIOS power setting (last power state, always on the...control the fans as passive requirements due to choose the lowest fan speeds and PowerEdge M1000e Technical Guide 33 This request is engineered for the Dell M1000e Modular Server Enclosure - The first power supply provides a small amount of the fan behavior. Each one is optimized ...
Technical Guide
Page 63
Dell o Monitoring and alerting for Industry-Standard Interfaces o SMASH CLP o WSMAN o CIM XML PowerEdge M1000e Technical Guide 62 This includes but is not limited to the following: Real time power consumption Power supplies Fans Power allocation Temperature CMC redundancy o I/O fabric consistency o Consolidated Status Reporting & Event Logs Email & SNMP alerting Support...
Dell o Monitoring and alerting for Industry-Standard Interfaces o SMASH CLP o WSMAN o CIM XML PowerEdge M1000e Technical Guide 62 This includes but is not limited to the following: Real time power consumption Power supplies Fans Power allocation Temperature CMC redundancy o I/O fabric consistency o Consolidated Status Reporting & Event Logs Email & SNMP alerting Support...