FTOS Configuration Guide for the S60 System FTOS 8.3.3.8
Page 752
... units in combination. • You may stack up to 12 S60 systems • You may not connect 12G and 24G stack ports. • All stack units must reload the unit. 752 | Stacking S-Series Switches Install stacking modules before powering the unit. calendar Display the ...stack up to the peer Stack-unit terminal Set terminal line parameters Stack(standby)>show Show running system information Important Points to Remember • You may stack up to eight S25/S50 systems in a stack. Accessing Non-Master Units on page 752 • Add a Unit to B. www.dell.com | support.dell...
... units in combination. • You may stack up to 12 S60 systems • You may not connect 12G and 24G stack ports. • All stack units must reload the unit. 752 | Stacking S-Series Switches Install stacking modules before powering the unit. calendar Display the ...stack up to the peer Stack-unit terminal Set terminal line parameters Stack(standby)>show Show running system information Important Points to Remember • You may stack up to eight S25/S50 systems in a stack. Accessing Non-Master Units on page 752 • Add a Unit to B. www.dell.com | support.dell...
FTOS Configuration Guide for the S60 System FTOS 8.3.3.8
Page 763
Module 0 -- Power Supplies -- Unit Bay Status Type 0 0 up Stacking S-Series Switches | 763 Figure 40-18. Unit Type : Member Unit Status : online Next Boot : online Required Type : S50V - 48-port E/FE/...d5:ef:81 No Of MACs : 3 -- Fan Status -- Unit 0 -- Module 1 -- Status : not present -- Status : online Module Type : S50-01-12G-2S Num Ports : 2 Hot Pluggable : no - 2-port 12G Stacking (SB) -- Displaying Information about an S-Series Stack-show system Force10#show system Stack MAC : 00:01:e8:d5:f9:6f -- Unit TrayStatus Speed Fan0 Fan1 ...
Module 0 -- Power Supplies -- Unit Bay Status Type 0 0 up Stacking S-Series Switches | 763 Figure 40-18. Unit Type : Member Unit Status : online Next Boot : online Required Type : S50V - 48-port E/FE/...d5:ef:81 No Of MACs : 3 -- Fan Status -- Unit 0 -- Module 1 -- Status : not present -- Status : online Module Type : S50-01-12G-2S Num Ports : 2 Hot Pluggable : no - 2-port 12G Stacking (SB) -- Displaying Information about an S-Series Stack-show system Force10#show system Stack MAC : 00:01:e8:d5:f9:6f -- Unit TrayStatus Speed Fan0 Fan1 ...
FTOS Configuration Guide for the S60 System FTOS 8.3.3.8
Page 764
... present No Module 0 2 0 not present No Module 0 2 1 online S50-01-12G-2S 2 -- Displaying Information about an S-Series Stack-show system stack-ports Force10#show system brief Stack MAC : 00:01:e8:d5:f9:6f -- Unit Bay Status Type 0 0 up AC 0 1 absent 1 0 absent 1 1 up DC 2 0 up AC 2 1 absent -- Power Supplies -- Fan Status -- www.dell.com | support.dell.com Figure 40...
... present No Module 0 2 0 not present No Module 0 2 1 online S50-01-12G-2S 2 -- Displaying Information about an S-Series Stack-show system stack-ports Force10#show system brief Stack MAC : 00:01:e8:d5:f9:6f -- Unit Bay Status Type 0 0 up AC 0 1 absent 1 0 absent 1 1 up DC 2 0 up AC 2 1 absent -- Power Supplies -- Fan Status -- www.dell.com | support.dell.com Figure 40...
FTOS Configuration Guide for the S60 System FTOS 8.3.3.8
Page 815
...AC 0 1 absent 1 0 up AC 1 1 absent 2 0 up AC 2 1 absent 3. S-Series Debugging and Diagnostics | 815 Module Info -- Message 2 Offline Diagnostics Complete Force10#00:09:32 : Diagnostic test results are printed to a file in the flash using the command diag, as shown in Figure 46-3 ... S50-01-12G-2S 2 1 0 online S50-01-10GE-2P 2 1 1 online S50-01-12G-2S 2 2 0 not present No Module 0 2 1 offline S50-01-12G-2S 2 -- Diagnostic results are stored on file: flash:/TestReport-SU-1.txt 00:09:37: %S50N:1 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1 ...
...AC 0 1 absent 1 0 up AC 1 1 absent 2 0 up AC 2 1 absent 3. S-Series Debugging and Diagnostics | 815 Module Info -- Message 2 Offline Diagnostics Complete Force10#00:09:32 : Diagnostic test results are printed to a file in the flash using the command diag, as shown in Figure 46-3 ... S50-01-12G-2S 2 1 0 online S50-01-10GE-2P 2 1 1 online S50-01-12G-2S 2 2 0 not present No Module 0 2 1 offline S50-01-12G-2S 2 -- Diagnostic results are stored on file: flash:/TestReport-SU-1.txt 00:09:37: %S50N:1 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1 ...
Installing the S60 System
Page 7
.... Figure 2-1. 2 The S60 System Introduction The Dell Force10 S60 system is a high-performance, high-capacity, low-cost, stackable, Layer 2 switch/ Layer 3 router that supports 44 built-in 10/100/1000 Base-T ports, four Small Form-Factor Pluggable (SFP) ports, an optional Small Form-Factor Pluggable Plus (SFP+) module, and optional 12G or 24G stacking modules. The front of...
.... Figure 2-1. 2 The S60 System Introduction The Dell Force10 S60 system is a high-performance, high-capacity, low-cost, stackable, Layer 2 switch/ Layer 3 router that supports 44 built-in 10/100/1000 Base-T ports, four Small Form-Factor Pluggable (SFP) ports, an optional Small Form-Factor Pluggable Plus (SFP+) module, and optional 12G or 24G stacking modules. The front of...
Installing the S60 System
Page 8
... S60-FAN-R S60 AC PSU with 1 fan module S60-PWR-AC S60 AC PSU with 1 reverse-flow fan module S60-PWR-AC-R S60 DC PSU with 1 fan module S60-PWR-DC S60 DC PSU with 1 reverse-flow fan module S60-PWR-DC-R S60 fan filter S60-PWR-FLTR S60 fan filter for NEBS compliance S60-PWR-FLTR-NEBS S60 2-port, 12 Gigabit stacking module S60-12G-2ST S60 1-port, 24 Gigabit stacking module S60-24G-1ST S60...
... S60-FAN-R S60 AC PSU with 1 fan module S60-PWR-AC S60 AC PSU with 1 reverse-flow fan module S60-PWR-AC-R S60 DC PSU with 1 fan module S60-PWR-DC S60 DC PSU with 1 reverse-flow fan module S60-PWR-DC-R S60 fan filter S60-PWR-FLTR S60 fan filter for NEBS compliance S60-PWR-FLTR-NEBS S60 2-port, 12 Gigabit stacking module S60-12G-2ST S60 1-port, 24 Gigabit stacking module S60-24G-1ST S60...
Installing the S60 System
Page 9
...fixed ports supporting 100/1000 Base-T or 1000 Base-X using auto-media detection • Optional ports supporting one 2-port, 24G stacking module or two 1-port, 12G stacking modules • Console port • Universal Serial Bus (USB)-A port • USB-B port System Status You can also view ...status information through the Command Line Interface (CLI) show commands and with Simple Network Management Protocol (SNMP) traps. You can view S60 status ...
...fixed ports supporting 100/1000 Base-T or 1000 Base-X using auto-media detection • Optional ports supporting one 2-port, 24G stacking module or two 1-port, 12G stacking modules • Console port • Universal Serial Bus (USB)-A port • USB-B port System Status You can also view ...status information through the Command Line Interface (CLI) show commands and with Simple Network Management Protocol (SNMP) traps. You can view S60 status ...
Installing the S60 System
Page 16
... interfaces and their configurations are created when you can install into the slot. Optional Modules Module Description 2-port, 12G stacking module Catalog Number S60-12G-2ST 1-port, 24G stacking module S60-24G-1ST 2-port, 10G SFP+ optical module S60-10GE-2S 16 | Install the S60 System www.dell.com | support.dell.com Step Task (continued) 3 Attach the two-hole lug to a suitable ground point. Torque...
... interfaces and their configurations are created when you can install into the slot. Optional Modules Module Description 2-port, 12G stacking module Catalog Number S60-12G-2ST 1-port, 24G stacking module S60-24G-1ST 2-port, 10G SFP+ optical module S60-10GE-2S 16 | Install the S60 System www.dell.com | support.dell.com Step Task (continued) 3 Attach the two-hole lug to a suitable ground point. Torque...
Installing the S60 System
Page 18
... front and the back side stacking modules. When stacking S60 systems, to Know • Do not mix stacking modules. To configure as a unified system, Dell Force10 supports stacking connections of up . Both ring topology and cascade topology connections are bi-directional. The stacking ports are supported (Figure 3-1 and Figure 3-2). If you use the 2-port, 12G stacking module, the stacking ports are labeled 48-49...
... front and the back side stacking modules. When stacking S60 systems, to Know • Do not mix stacking modules. To configure as a unified system, Dell Force10 supports stacking connections of up . Both ring topology and cascade topology connections are bi-directional. The stacking ports are supported (Figure 3-1 and Figure 3-2). If you use the 2-port, 12G stacking module, the stacking ports are labeled 48-49...
Installing the S60 System
Page 19
... -B connections, the ports are bi-directional so you make your stacking port connections, rack-mount the stacking systems or insert them into Stack Port 48 (or 50). 2 Insert the other open stack ports (Figure 3-4). Connect Two S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable into the other end of the...
... -B connections, the ports are bi-directional so you make your stacking port connections, rack-mount the stacking systems or insert them into Stack Port 48 (or 50). 2 Insert the other open stack ports (Figure 3-4). Connect Two S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable into the other end of the...
Installing the S60 System
Page 20
.... 20 | Install the S60 System To connect 1-port, 24G stacking modules, starting with 2-port, 12G Stacking Modules Connected in a Ring Topology Connect Three or More S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable ...into the other end of the cable into Stack Port 50 (or 48) of the top S60 system. 3 Insert the second cable into Stack Port 50 (or 48) of the first cable into Stack Port 48 (or 50). 2 Insert the other open stack ports (Figure 3-5). www.dell.com | support.dell...
.... 20 | Install the S60 System To connect 1-port, 24G stacking modules, starting with 2-port, 12G Stacking Modules Connected in a Ring Topology Connect Three or More S60 Systems 2-port, 12G Stacking Modules As an option, when using the 2-port, 12G stacking modules, insert a second cable ...into the other end of the cable into Stack Port 50 (or 48) of the top S60 system. 3 Insert the second cable into Stack Port 50 (or 48) of the first cable into Stack Port 48 (or 50). 2 Insert the other open stack ports (Figure 3-5). www.dell.com | support.dell...
Installing the S60 System
Page 21
...Insert the other end of the cable into Stack Port 48 (or 50) of the middle S60 system. 3 Insert the second cable into Stack Port 49 (or 51) of the middle and top S60 systems. 4 Use the remaining cable to connect the top and bottom S60 systems by inserting one end of the cable... into the open Stack Port 49 (or 51) of the bottom S60 system and the other end of the cable into Stack Port 48 (or 50) of the top S60 system. Figure 3-5. To connect 2-port, 12G stacking modules, starting with 2-port, 12G Stacking Modules Connected in a ...
...Insert the other end of the cable into Stack Port 48 (or 50) of the middle S60 system. 3 Insert the second cable into Stack Port 49 (or 51) of the middle and top S60 systems. 4 Use the remaining cable to connect the top and bottom S60 systems by inserting one end of the cable... into the open Stack Port 49 (or 51) of the bottom S60 system and the other end of the cable into Stack Port 48 (or 50) of the top S60 system. Figure 3-5. To connect 2-port, 12G stacking modules, starting with 2-port, 12G Stacking Modules Connected in a ...