FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 83
... option is available on the E300, E600/E600i, and E1200. Enter the keyword 3.2 to set the epoch to 2.4 micro-seconds and lower the latency. This is the default setting and is supported on FTOS versions 8.2.1.0 and earlier. Defaults 10.4
Command Modes CONFIGURATION
Command History
Version 8.3.1.0
Version 8.1.1.2 Version 8.1.1.0 Version 6.2.1.1 Version 6.1.1.0
Added 2.4 micro-seconds option...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 120
... Date Code
Description
Displays the line card slot number (only listed in EtherScale or TeraScale mode. The Required Type and Current Type must match. Displays the chip set revision. Displays Yes or No indicating if the line card can support Jumbo frames. Displays the line card part number. Table 5-1. Displays the line card type configured...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 454
www.dell.com | support.dell.com
show run diff {flash: | startup-config}
Parameters
flash: startup-config
Enter the archive configuration file using the path [flash://]filename
Enter the keywords startup-config to all terminal line users.
When set to auto, FTOS automatically denies access to CONFIGURATION mode to compare the contents of the startup configuration.
Syntax show run ...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1560
... of the RPM. Enter the keyword card-problem to enable automatic parity corrections for the party-bus control switch on -error to take an action upon a hardware error.
Range: 0 -1
Defaults No default behavior or values
Command Mode
EXEC EXEC Privilege
Command History
Version 6.5.4.0
Introduced
hardware monitor linecard
e Configure the system to further specify actions that should...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1573
...may be useful during troubleshooting line card initialization errors, such as downed Port-Pipe.
hardware monitor mac action-on-error port-shutdown hardware monitor linecard asic BTM action-on-error card-reset hardware monitor linecard asic FPC action-on -error settings. show running-config hardware-monitor Command Example
FTOS#show running -config hardware-monitor
Defaults No default values or...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1596
SNMP Traps and Error Messages (continued)
Message ID
Trap Type
CHM_CARD_DOWN
ENVMON
%CHMGR... Minor alarm cleared: Working standby SFM present
CHM_PWRSRC_DOWN
ENVMON
%CHMGR-2-PEM_PRBLM: Major alarm: problem with power entry module %s
NONE NONE NONE
NONE NONE NONE NONE NONE NONE SUPPLY
1596...CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down - www.dell.com | support.dell.com
Table B-1.
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1614
...dell.com | support.dell...service password-encryption 1291 service timestamps 102 service-class dynamic dot1p 1184 service-class dynamic dot1p (QoS) 1184, 1185 service-policy input 1205 service-policy output 1206 service-queue 1206 set (policy QoS) 1207 set as-path prepend (Route Map) 278 set automatic-tag (Route Map) 278 set comm-list (Route Map) 279 set... 876 show cam mac stack-unit 879 show cam ...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1635
... rstp 1270 show config 1270 show spanning-tree rstp 1271 spanning-tree rstp 1273 run-cpu 513
S
sample-rate 513 schedule 497
SCP
ip scp topdir 1312 scramble-atm (SONET) 1395
Security
aaa authentication login 1285 enable password 1287 enable restricted 1288 login authentication 1289 password 1290 privilege level 1283 service password-encryption 1291 show...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 102
....
• Link Fault-A fault occurred in subsequent OAMPDUs until the error is sent to take an additional action. each has an associated flag which can configure the system to the peer. When a link fault, dying gasp, or critical event occurs, the system sets an associated bit in the receive direction of the local...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 224
... (MED) (default) • a path with a large-scale configuration (large number of BGP neighbors and a large
BGP Loc-RIB), Dell Force10 recommends setting the timeout and retry count values to the f10BgpM2PeerCountersEntry table. e.g. F10BgpM2NlriOpaqueType and f10BgpM2NlriOpaquePointer fields are set to ignore such errors. • Multiple BPG process instances are not supported. If disabled...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 380
...the chassis with dual RPMs on page 381 • Automatic and manual RPM failover on page 382 • Support for each component. FTOS displays Message 1 when the standby RPM is... the switch fabric, even though the second RPM comes online as the standby, the switch fabric is active and participates in Standby State. www.dell.com | support.dell.com
Component Redundancy
Dell Force10 systems ...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 398
...Service Modular patch replaces the existing process code....dell.com | support.dell.com
In-Service Modular Hot-Fixes
e In-Service ...CONFIGURATION
For example: patch flash://RUNTIME_PATCH_DIR/7.8.0.1-EH-rp1-bgp-1.rtp
View all In-Service patches on platforms:
In-Service Modular Hot-Fixes provides a tool whereby you can install a patch while the system is complete, the system executes the patch code...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 450
www.dell.com | support.dell.com
Figure 20... IP MTU
Ethernet Pause Frames
c e s Ethernet Pause Frames is supported on platforms c s Threshold Settings are supported only on an Interface
The E-Series supports a link Maximum Transmission Unit (MTU) of 9252 bytes and maximum IP...• show interfaces interface x/y
Configure MTU size on platforms:
Ethernet Pause Frames allow for IP fragmentation.
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511
... an IS for installing in the FIB • Accept external IPv6 information and advertise this information in IIH and the first fragment of time manually. Its structure is added to achieve database synchronization (by setting a specific amount of an LSP.
• The MT Intermediate Systems TLV appears for every topology a node supports.
however, the ISO...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1208
As described in the
TRACE_LOG_DIR - Auto failover on heart beat lost with Dell Force10 technical support staff. CP trace log file (look for troubleshooting specific problems while working with peer RPM. Hardware watchdog timer
The hardware watchdog command automatically reboots an FTOS switch/router with the phrase "failure_trace") in the High Availability chapter, an RPM failover can ...
Dell Force10 S50P Reviews
Do you have an experience with the Dell Force10 S50P that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Dell yet.