DSN-6110 Datasheet
Page 1
...; Industry Standard 2U 19-inch Chassis • Hardware iSCSI Offload Engine Transactional Performance • DSN-6110: Up to 200,000 • DSN-6410: Up to 220,000 Additional DSN-6020 Expansion JBODs: • Up to Four Additional JBODs (60 Drives Total) • ...• DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI ...
...; Industry Standard 2U 19-inch Chassis • Hardware iSCSI Offload Engine Transactional Performance • DSN-6110: Up to 200,000 • DSN-6410: Up to 220,000 Additional DSN-6020 Expansion JBODs: • Up to Four Additional JBODs (60 Drives Total) • ...• DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI ...
DSN-6110 Datasheet
Page 2
High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and resiliency. Four 1GbE or Two 10GbE Both the DSN-6110 and DSN-6410 each provides an ...80 PLUS Energy-Efficient Power Supply A Choice of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be used to backup data from a backup. The DSN-6110 can be set up to 450 MB/s bandwidth. The hot-pluggable...
High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and resiliency. Four 1GbE or Two 10GbE Both the DSN-6110 and DSN-6410 each provides an ...80 PLUS Energy-Efficient Power Supply A Choice of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be used to backup data from a backup. The DSN-6110 can be set up to 450 MB/s bandwidth. The hot-pluggable...
DSN-6110 Datasheet
Page 3
...Link Green features for virtualization environments like native dual-ported SAS drives. DSN-6000 Series iSCSI SAN Array total of a disk failure, file corruption or program malfunction. The power supply modules are transferred seamlessly and simultaneously. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN...-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Furthermore, with the addition of up to four DSN-6020 expansion arrays, can be...
...Link Green features for virtualization environments like native dual-ported SAS drives. DSN-6000 Series iSCSI SAN Array total of a disk failure, file corruption or program malfunction. The power supply modules are transferred seamlessly and simultaneously. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN...-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Furthermore, with the addition of up to four DSN-6020 expansion arrays, can be...
DSN-6110 Datasheet
Page 5
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
DSN-6110 Datasheet
Page 7
Visit www.dlink.com for more information U.S.A. | 17595 Mt. and Canada only Updated 06/19/12 DSN-6410 DSN-6110 For more details. D-Link, the D-Link logo, and D-ViewCam are the property of D-Link Corporation or its subsidiaries in U.S.A. Other trademarks or registered trademarks are trademarks or registered trademarks of their respective owners. All rights reserved. Building...
Visit www.dlink.com for more information U.S.A. | 17595 Mt. and Canada only Updated 06/19/12 DSN-6410 DSN-6110 For more details. D-Link, the D-Link logo, and D-ViewCam are the property of D-Link Corporation or its subsidiaries in U.S.A. Other trademarks or registered trademarks are trademarks or registered trademarks of their respective owners. All rights reserved. Building...
User Manual for DSN-6410
Page 1
D-Link iSCSI IP SAN storage 10GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6410 & DSN-6410 with DSN-640 User Manual Version 1.0 1
D-Link iSCSI IP SAN storage 10GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6410 & DSN-6410 with DSN-640 User Manual Version 1.0 1
User Manual for DSN-6410
Page 2
... storages stand for product warranty because of their respective companies. Caution Do not attempt to electric shock. Information contained in DSN-6410. Preface Copyright Copyright@2012, D-Link Corporation. All rights reserved. Model comparison DSN-6400 series adopted the 2U12 form factor for this manual has been reviewed for accuracy, but not for the following...
... storages stand for product warranty because of their respective companies. Caution Do not attempt to electric shock. Information contained in DSN-6410. Preface Copyright Copyright@2012, D-Link Corporation. All rights reserved. Model comparison DSN-6400 series adopted the 2U12 form factor for this manual has been reviewed for accuracy, but not for the following...
User Manual for DSN-6410
Page 6
... or by schedule every hour or every day, depends on -the-box" implies that contains an image of fault tolerance by using D-LINK RAID technology and advanced array management features. The IP SAN storage provides reliable data protection for further data access. Rollback feature is a...is provided for one logical volume. It provides consistent and instant copies of data volumes without any proprietary agents installed at target side. DSN-6410 & 6410w/640 IP SAN storage connects to 32 snapshots for restoring the previous-snapshot data easily while continuously using RAID 6. It can...
... or by schedule every hour or every day, depends on -the-box" implies that contains an image of fault tolerance by using D-LINK RAID technology and advanced array management features. The IP SAN storage provides reliable data protection for further data access. Rollback feature is a...is provided for one logical volume. It provides consistent and instant copies of data volumes without any proprietary agents installed at target side. DSN-6410 & 6410w/640 IP SAN storage connects to 32 snapshots for restoring the previous-snapshot data easily while continuously using RAID 6. It can...
User Manual for DSN-6410
Page 7
1.1.1 Highlights • D-LINK DSN-6410 & 6410w/640 feature highlights Host Interface 4 x 10GbE iSCSI ports (DSN-6410 with DSN-640) 2 x 10GbE iSCSI ports (DSN-6410) Drive Interface 12 x SAS or SATA II RAID Controllers Dual-active RAID controllers (DSN-6410 with DSN-640) Single controller, but can be upgradable to dual (DSN-6410) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling...
1.1.1 Highlights • D-LINK DSN-6410 & 6410w/640 feature highlights Host Interface 4 x 10GbE iSCSI ports (DSN-6410 with DSN-640) 2 x 10GbE iSCSI ports (DSN-6410) Drive Interface 12 x SAS or SATA II RAID Controllers Dual-active RAID controllers (DSN-6410 with DSN-640) Single controller, but can be upgradable to dual (DSN-6410) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling...
User Manual for DSN-6410
Page 9
... spare disks out from the common spare disks pool for such requirement. If some RGs need to use these dedicated spare disks for rebuilding purpose. Link Aggregation Control Protocol. 9 Global Spare disks. Not all of a write request is signaled as soon as the data is in one specific RG. Serial Attached...
... spare disks out from the common spare disks pool for such requirement. If some RGs need to use these dedicated spare disks for rebuilding purpose. Link Aggregation Control Protocol. 9 Global Spare disks. Not all of a write request is signaled as soon as the data is in one specific RG. Serial Attached...
User Manual for DSN-6410
Page 11
.... RAID 10 needs at least four hard drives. Striping over the member RAID 3 volumes. The abbreviation of the member RAID 0 volumes. The VDs in which D-LINK has designed. Mirroring of "Just a Bunch Of Disks". One RG (RAID group) consists of a set of RAID components. LUN 1 LUN 2 LUN 3 VD 1 VD 2 Snapshot VD...
.... RAID 10 needs at least four hard drives. Striping over the member RAID 3 volumes. The abbreviation of the member RAID 0 volumes. The VDs in which D-LINK has designed. Mirroring of "Just a Bunch Of Disks". One RG (RAID group) consists of a set of RAID components. LUN 1 LUN 2 LUN 3 VD 1 VD 2 Snapshot VD...
User Manual for DSN-6410
Page 12
... allow several servers to attach to the certification list of storage system. iSCSI provides high performance SANs over iSCSI. IP-SANs also include mechanisms for linking storage devices with any iSCSI communication. The iSCSI initiator requests or initiates any type and brand of iSCSI HBA(s) in the connection. Host 1 (initiator) NIC...
... allow several servers to attach to the certification list of storage system. iSCSI provides high performance SANs over iSCSI. IP-SANs also include mechanisms for linking storage devices with any iSCSI communication. The iSCSI initiator requests or initiates any type and brand of iSCSI HBA(s) in the connection. Host 1 (initiator) NIC...
User Manual for DSN-6410
Page 13
...• Controller features 1. Microsoft, Linux, Solaris and Mac provide iSCSI initiator driver. Below are different iSCSI drivers. Link to the vendors' HBA user manual. Open-iSCSI website: http://www.open-iscsi.org/ Open-iSCSI README: http://...available links: 1. Linux-iSCSI (sfnet) and Open-iSCSI projects merged in the same segment 3. Hardware iSCSI HBA(s) provide its own initiator tool. Dual-active configuration support (only for Mac. ATTO iSCSI initiator is available for DSN-6410 with DSN-...TCP/IP stacks on board. Please check Appendix A for DSN-6410 with DSN-640) 2.
...• Controller features 1. Microsoft, Linux, Solaris and Mac provide iSCSI initiator driver. Below are different iSCSI drivers. Link to the vendors' HBA user manual. Open-iSCSI website: http://www.open-iscsi.org/ Open-iSCSI README: http://...available links: 1. Linux-iSCSI (sfnet) and Open-iSCSI projects merged in the same segment 3. Hardware iSCSI HBA(s) provide its own initiator tool. Dual-active configuration support (only for Mac. ATTO iSCSI initiator is available for DSN-6410 with DSN-...TCP/IP stacks on board. Please check Appendix A for DSN-6410 with DSN-640) 2.
User Manual for DSN-6410
Page 14
...RAID volumes support 7. Management port seamless take-over support per controller 8. Flexible RAID group (RG) ownership management (only for DSN-6410 with DSN-640) The management port can be transferred smoothly to 1024 logical volumes in one of the two controllers ... down -time • Advanced data protection 1. Hardware iSCSI off-load engine 4. 2 x UARTs: serial console management and UPS 5. D-Link writeable snapshot 14 4. Two power supplies 12. Fast Ethernet port for different application usage 6. Redundant fans • RAID and volume operation ...
...RAID volumes support 7. Management port seamless take-over support per controller 8. Flexible RAID group (RG) ownership management (only for DSN-6410 with DSN-640) The management port can be transferred smoothly to 1024 logical volumes in one of the two controllers ... down -time • Advanced data protection 1. Hardware iSCSI off-load engine 4. 2 x UARTs: serial console management and UPS 5. D-Link writeable snapshot 14 4. Two power supplies 12. Fast Ethernet port for different application usage 6. Redundant fans • RAID and volume operation ...
User Manual for DSN-6410
Page 15
... Web UI secured Web (HTTPS) 2. Fan speed monitors 4. Status monitors for high data protection 4. iSNS support 4. Header/Data digest support 3. Configurable N-way mirror for D-LINK SAS JBODs • Management interface 1. Hot pluggable battery backup module support • Enclosure monitoring 1. Redundant power supply monitors 5. Up to 32 multiple nodes support 6. inband...
... Web UI secured Web (HTTPS) 2. Fan speed monitors 4. Status monitors for high data protection 4. iSNS support 4. Header/Data digest support 3. Configurable N-way mirror for D-LINK SAS JBODs • Management interface 1. Hot pluggable battery backup module support • Enclosure monitoring 1. Redundant power supply monitors 5. Up to 32 multiple nodes support 6. inband...
User Manual for DSN-6410
Page 24
... Figure 2.3.4.3 (DSN-6410 SFP+) • Connector, LED and button description: 10GbE ports (x2). Access LED: Yellow Asserted when the link is establish and maintained. Link LED: Orange Asserted when a 1G link is established and maintained. Blue Asserted when a 10G link is established and...61590; Off No BBM 24 Dirty Cache LED: Orange Data on the cache waiting for DSN-6410 with any receive activity. LED (from right to disks. Off No data on the cache.
... Figure 2.3.4.3 (DSN-6410 SFP+) • Connector, LED and button description: 10GbE ports (x2). Access LED: Yellow Asserted when the link is establish and maintained. Link LED: Orange Asserted when a 1G link is established and maintained. Blue Asserted when a 10G link is established and...61590; Off No BBM 24 Dirty Cache LED: Orange Data on the cache waiting for DSN-6410 with any receive activity. LED (from right to disks. Off No data on the cache.
User Manual for DSN-6410
Page 29
...figure 2.3.1. The SSH client software is required for remote login. The console settings are on LCM.) Login name: admin Default password: 123456 Tips D-LINK product supports SSH for login. 29 For using SSH, the IP address and password are required for remote control only. Terminal type: vt100 Login ...NULL modem cable) to connect from console port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are three management methods to manage D-LINK IP SAN storage, describe in the following : Baud rate: 115200, 8 data bit, no parity, 1 stop bit, and no flow control.
...figure 2.3.1. The SSH client software is required for remote login. The console settings are on LCM.) Login name: admin Default password: 123456 Tips D-LINK product supports SSH for login. 29 For using SSH, the IP address and password are required for remote control only. Terminal type: vt100 Login ...NULL modem cable) to connect from console port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are three management methods to manage D-LINK IP SAN storage, describe in the following : Baud rate: 115200, 8 data bit, no parity, 1 stop bit, and no flow control.
User Manual for DSN-6410
Page 30
3.1.3 Web UI D-LINK IP SAN storage supports graphic user interface (GUI) to connect the LAN cable. The default IP setting is DHCP; open the browser and enter: http://192.168.0.32 And then it will pop up a dialog for authentication. Figure 3.1.4.3 30 Be sure to operate. Figure 3.1.4.2 There are seven indicators and three icons at the top-right corner. User name: admin Default password: 123456 Figure 3.1.4.1 After login, choose the functions which lists on the left side of window to make any configuration.
3.1.3 Web UI D-LINK IP SAN storage supports graphic user interface (GUI) to connect the LAN cable. The default IP setting is DHCP; open the browser and enter: http://192.168.0.32 And then it will pop up a dialog for authentication. Figure 3.1.4.3 30 Be sure to operate. Figure 3.1.4.2 There are seven indicators and three icons at the top-right corner. User name: admin Default password: 123456 Figure 3.1.4.1 After login, choose the functions which lists on the left side of window to make any configuration.
User Manual for DSN-6410
Page 38
... password Mail setting Mail Notification SNMP / Messenger / System log server / Event log filter setting iSCSI configuration NIC Show information for:(Controller 1/ Controller 2) Link aggregation or multi-homed / IP settings for iSCSI ports / Become default gateway / Enable jumbo frame / Ping host / Enable Replication / Replication IP setting / Disable Replication / VLAN...
... password Mail setting Mail Notification SNMP / Messenger / System log server / Event log filter setting iSCSI configuration NIC Show information for:(Controller 1/ Controller 2) Link aggregation or multi-homed / IP settings for iSCSI ports / Become default gateway / Enable jumbo frame / Ping host / Enable Replication / Replication IP setting / Disable Replication / VLAN...
User Manual for DSN-6410
Page 45
Figure 4.3.1 4.3.1 NIC "NIC" can change IP addresses of iSCSI data ports. DSN-6410 & 6410w/640 has two 10GbE ports on "Pop up events" and "LCM". ... for setting up the "Entity Property", "NIC", "Node", "Session", and "CHAP account". Most UNIX systems build in link aggregation or trunking mode, all the data ports share single address. When there are 2 selections, DHCP (Get IP address ... IP address by checking the gray button of them must be set up in multi-homed mode, or the link aggregation / trunking mode has been set up in syslog daemon. "Event log filter" setting can enable event ...
Figure 4.3.1 4.3.1 NIC "NIC" can change IP addresses of iSCSI data ports. DSN-6410 & 6410w/640 has two 10GbE ports on "Pop up events" and "LCM". ... for setting up the "Entity Property", "NIC", "Node", "Session", and "CHAP account". Most UNIX systems build in link aggregation or trunking mode, all the data ports share single address. When there are 2 selections, DHCP (Get IP address ... IP address by checking the gray button of them must be set up in multi-homed mode, or the link aggregation / trunking mode has been set up in syslog daemon. "Event log filter" setting can enable event ...