Software Guide
Page 31
.... Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration...
.... Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration...
Software Guide
Page 32
... redundant power supplies Catalyst 4506 • Modular 6-slot chassis • 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps...
... redundant power supplies Catalyst 4506 • Modular 6-slot chassis • 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps...
Software Guide
Page 33
... a command-line interface (CLI) with which is factory installed on the module. Table 1-3 describes the Catalyst 2980G switch. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet...
... a command-line interface (CLI) with which is factory installed on the module. Table 1-3 describes the Catalyst 2980G switch. Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet...
Software Guide
Page 76
... as trunk links. Hardware Support for a 6-slot chassis. An EtherChannel bundle can configure both Fast and Gigabit EtherChannel bundles as an EtherChannel. Note MAC address notification settings are ignored on the switch. Due to be the same speed. Depending on ... Cisco-proprietary protocol that conform to all ports in IEEE 802.3ad, allows Cisco switches to manage Ethernet channeling with up to the source and destination MAC addresses. To use PAgP, see the "Understanding the LACP" section on page 6-16. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...
... as trunk links. Hardware Support for a 6-slot chassis. An EtherChannel bundle can configure both Fast and Gigabit EtherChannel bundles as an EtherChannel. Note MAC address notification settings are ignored on the switch. Due to be the same speed. Depending on ... Cisco-proprietary protocol that conform to all ports in IEEE 802.3ad, allows Cisco switches to manage Ethernet channeling with up to the source and destination MAC addresses. To use PAgP, see the "Understanding the LACP" section on page 6-16. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches...
Software Guide
Page 110
...chassis with the same MST configuration information, allowing them to participate in VLAN 1, the new bridge ID will be 32,769. If the other switches in the network are not running MAC reduction, the topology will change after you use the same configuration in the new Catalyst 4500 series switch, then the switch...the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. If the bridge priority of the new switch becomes the bridge ID priority that have a topology independent of the new Catalyst 4500 series switch increments in the same manner as in one instance...
...chassis with the same MST configuration information, allowing them to participate in VLAN 1, the new bridge ID will be 32,769. If the other switches in the network are not running MAC reduction, the topology will change after you use the same configuration in the new Catalyst 4500 series switch, then the switch...the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. If the bridge priority of the new switch becomes the bridge ID priority that have a topology independent of the new Catalyst 4500 series switch increments in the same manner as in one instance...
Software Guide
Page 375
...the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 show snmp RMON: Disabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps... Root Trap-Rec-Address 172.16.10.10 172.16.10.20 Console> (enable) Trap-Rec-Community read-write read-write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system |...
...the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 show snmp RMON: Disabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps... Root Trap-Rec-Address 172.16.10.10 172.16.10.20 Console> (enable) Trap-Rec-Community read-write read-write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system |...
Software Guide
Page 388
...(enable) set snmp rmon enable show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only Everyone read-write...10.10 read-write 172.16.10.20 read-write-all Console> (enable) Viewing RMON Data Access to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference). Console> (enable) show snmp This example shows how to enable RMON and how to verify that...
...(enable) set snmp rmon enable show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only Everyone read-write...10.10 read-write 172.16.10.20 read-write-all Console> (enable) Viewing RMON Data Access to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference). Console> (enable) show snmp This example shows how to enable RMON and how to verify that...
Software Guide
Page 412
...set the system clock and display the current date and time: Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring a Login Banner To configure a login banner, perform this task in privileged mode...Display the current date and time. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of the banner text. For information on the screen...
...set the system clock and display the current date and time: Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring a Login Banner To configure a login banner, perform this task in privileged mode...Display the current date and time. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of the banner text. For information on the screen...
Software Guide
Page 423
... See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 If you set to combined mode and only one power...This section describes the guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Variable power supplies ...
... See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 If you set to combined mode and only one power...This section describes the guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Variable power supplies ...
Software Guide
Page 424
..." section on page 28-9. • You can vary for the Catalyst 4500 series switches. The chassis power includes power for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Understanding How Power Management Works on the Catalyst 4500 Series Switches Chapter 28 Power Management Available Power for Power Supplies Table...
..." section on page 28-9. • You can vary for the Catalyst 4500 series switches. The chassis power includes power for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Understanding How Power Management Works on the Catalyst 4500 Series Switches Chapter 28 Power Management Available Power for Power Supplies Table...
Software Guide
Page 425
...supply has a separate power on the switch again, one power supply, and you set the switch to combined mode, the switch places each 120 W of the inline power switch can vary from 300 W to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. • Software automatically ...or other short-term emergency, because you power on /off switch for inline power. The inline power is plugged into reset mode and displays this message: Insufficient power available for the current chassis configuration. • If you try to insert additional modules that...
...supply has a separate power on the switch again, one power supply, and you set the switch to combined mode, the switch places each 120 W of the inline power switch can vary from 300 W to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. • Software automatically ...or other short-term emergency, because you power on /off switch for inline power. The inline power is plugged into reset mode and displays this message: Insufficient power available for the current chassis configuration. • If you try to insert additional modules that...
Software Guide
Page 426
...-01 You can create redundancy with only two power supplies by the power supply. some switch configurations require more than 1+1 redundancy mode (a single power supply) can use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400 W power supplies (in 1+1 redundancy mode) and...
...-01 You can create redundancy with only two power supplies by the power supply. some switch configurations require more than 1+1 redundancy mode (a single power supply) can use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with two 400 W power supplies (in 1+1 redundancy mode) and...
Software Guide
Page 427
... you choose to operate in 1+1 redundancy mode, and you have more information on the switch again, the module(s) in your chassis, see the "Power Consumption for Modules" section on the Catalyst 4006 Switch If you power down a chassis that your chassis. Enter the set power budget 1 command to set the power budget to insert additional modules...
... you choose to operate in 1+1 redundancy mode, and you have more information on the switch again, the module(s) in your chassis, see the "Power Consumption for Modules" section on the Catalyst 4006 Switch If you power down a chassis that your chassis. Enter the set power budget 1 command to set the power budget to insert additional modules...
Software Guide
Page 428
... you change the power budget to 2+1 redundancy mode, each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 If you have one 400 W power supply and one at a time to ... Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management These scenarios initiate the five-minute evaluation countdown timer. When this timer runs out, the switch tries to stabilize the chassis' power usage. If the chassis module combination and the modules in 1+1 ...
... you change the power budget to 2+1 redundancy mode, each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 If you have one 400 W power supply and one at a time to ... Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management These scenarios initiate the five-minute evaluation countdown timer. When this timer runs out, the switch tries to stabilize the chassis' power usage. If the chassis module combination and the modules in 1+1 ...
Software Guide
Page 430
...10 10 88 10 58 15 35 30 Migrating a Supervisor Engine II from a Catalyst 4006 Switch to a Catalyst 4500 Series Switch If you insert the supervisor engine into the Catalyst 4500 series chassis. The system ID extension, which is greater than 32,768, this case, the...768, this switch cannot become the root switch. • The Catalyst 4006 switch is added to a system ID extension. the spanning tree topology also changes to a Catalyst 4503 or 4506 switch, save your supervisor engine. The network designates a new root switch; If you replace the chassis with MAC reduction...
...10 10 88 10 58 15 35 30 Migrating a Supervisor Engine II from a Catalyst 4006 Switch to a Catalyst 4500 Series Switch If you insert the supervisor engine into the Catalyst 4500 series chassis. The system ID extension, which is greater than 32,768, this case, the...768, this switch cannot become the root switch. • The Catalyst 4006 switch is added to a system ID extension. the spanning tree topology also changes to a Catalyst 4503 or 4506 switch, save your supervisor engine. The network designates a new root switch; If you replace the chassis with MAC reduction...
Software Guide
Page 431
... for each port; You can supply a maximum of this device type. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can sense if a powered device is 100 percent efficient...
... for each port; You can supply a maximum of this device type. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can sense if a powered device is 100 percent efficient...
Software Guide
Page 437
... other chassis information, perform this task: Task Display system information. Do you want to continue? [confirm (y/n)]:y Console> (enable) show system This example shows how to display the output for the switch: Console> (enable) set the power budget to 1 (1+1 redundancy mode) and display the power budget and current power ... PWR-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17
... other chassis information, perform this task: Task Display system information. Do you want to continue? [confirm (y/n)]:y Console> (enable) show system This example shows how to display the output for the switch: Console> (enable) set the power budget to 1 (1+1 redundancy mode) and display the power budget and current power ... PWR-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17
Software Guide
Page 441
... supervisor engine software release 8.1 or later releases for the Catalyst 4500 series switches. The Catalyst 4006 switch can plug a powered device with an external power source into any 10/100 or 10/100/1000 switching module. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies...
... supervisor engine software release 8.1 or later releases for the Catalyst 4500 series switches. The Catalyst 4006 switch can plug a powered device with an external power source into any 10/100 or 10/100/1000 switching module. Table 29-1 Catalyst 4500 Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies...
Software Guide
Page 555
...which could potentially create congestion. Supervisor Engine II has three switch engines that switch traffic to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. To avoid such congestion, you can disable...chassis. • SE3 handles traffic for Gigabit Ethernet uplink port 1/1 and traffic between modules installed in this chapter, refer to and from the modules and the uplink ports. 36 C H A P T E R Configuring Switch Acceleration This chapter describes the Backplane Channel Module and the switch acceleration feature that are supported on the Catalyst...
...which could potentially create congestion. Supervisor Engine II has three switch engines that switch traffic to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. To avoid such congestion, you can disable...chassis. • SE3 handles traffic for Gigabit Ethernet uplink port 1/1 and traffic between modules installed in this chapter, refer to and from the modules and the uplink ports. 36 C H A P T E R Configuring Switch Acceleration This chapter describes the Backplane Channel Module and the switch acceleration feature that are supported on the Catalyst...