Software Guide
Page 31
Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide...
Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane • Two power supplies with optional third power supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide...
Software Guide
Page 32
... redundant power supplies Catalyst 4506 • Modular 6-slot chassis • 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps...
... redundant power supplies Catalyst 4506 • Modular 6-slot chassis • 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps...
Software Guide
Page 33
... the Command-Line Interface." For descriptions of the Catalyst 2980G switch hardware, refer to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 1-3 Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power...
... the Command-Line Interface." For descriptions of the Catalyst 2980G switch hardware, refer to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 1-3 Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power...
Software Guide
Page 76
... have to determine whether your hardware, you can configure any two to eight compatibly configured Fast or Gigabit Ethernet ports on the Catalyst 4500 series switches, you group multiple Fast or Gigabit Ethernet ports into a single EtherChannel. To use LACP, see the "Understanding the LACP"... Ports." The frame distribution method is hardware dependent. Hardware Support for a 6-slot chassis. All ports in the channel as trunk links. PAgP is defined in IEEE 802.3ad, allows Cisco switches to manage Ethernet channeling with devices that can be run only on the low-order...
... have to determine whether your hardware, you can configure any two to eight compatibly configured Fast or Gigabit Ethernet ports on the Catalyst 4500 series switches, you group multiple Fast or Gigabit Ethernet ports into a single EtherChannel. To use LACP, see the "Understanding the LACP"... Ports." The frame distribution method is hardware dependent. Hardware Support for a 6-slot chassis. All ports in the channel as trunk links. PAgP is defined in IEEE 802.3ad, allows Cisco switches to manage Ethernet channeling with devices that can be run only on the low-order...
Software Guide
Page 110
... draft version of the new Catalyst 4500 series switch increments in the same manner as implemented in a given set to 32,768 to the network, the bridge ID priority of the Catalyst 4006 has been lowered administratively and you replace the chassis with the same MST configuration ...STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. The bridge ID priority of the IEEE standard. MST allows you migrate your supervisor engine from a Catalyst 4006 switch to a Catalyst 4500 series switch, see the "Migrating a Supervisor Engine II from 1 to spanning tree ...
... draft version of the new Catalyst 4500 series switch increments in the same manner as implemented in a given set to 32,768 to the network, the bridge ID priority of the Catalyst 4006 has been lowered administratively and you replace the chassis with the same MST configuration ...STP, 802.1w, the Rapid Spanning Tree Protocol (RSTP), and the Cisco PVST+ architecture. The bridge ID priority of the IEEE standard. MST allows you migrate your supervisor engine from a Catalyst 4006 switch to a Catalyst 4500 series switch, see the "Migrating a Supervisor Engine II from 1 to spanning tree ...
Software Guide
Page 375
...-Rec-Community read-write read -write-all SNMP trap receiver added. Console> (enable) set snmp community read-write Administrators SNMP read -write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate | vlandelete | vmps | vtp]... Step 1 Step 2 Step 3 Step 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7
...-Rec-Community read-write read -write-all SNMP trap receiver added. Console> (enable) set snmp community read-write Administrators SNMP read -write-all | auth | bridge | chassis | config | entity | entityfru | envfan | envpower | envshutdown | envtemp | flashinsert | flashremove | ippermit | module | stpx | syslog | system | vlancreate | vlandelete | vmps | vtp]... Step 1 Step 2 Step 3 Step 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7
Software Guide
Page 388
... enabled. Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 To enable RMON, perform this procedure in privileged mode: Step 1 Step...MIB Objects Table 25-1 lists the RMON and RMON2 MIB objects that RMON is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only...
... enabled. Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 To enable RMON, perform this procedure in privileged mode: Step 1 Step...MIB Objects Table 25-1 lists the RMON and RMON2 MIB objects that RMON is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-only...
Software Guide
Page 412
... Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Characters following the motd keyword is used to the switch. The first character following the ending delimiter are discarded. The banner ...the ending delimiter, press Return. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System...
... Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Characters following the motd keyword is used to the switch. The first character following the ending delimiter are discarded. The banner ...the ending delimiter, press Return. Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System...
Software Guide
Page 423
...8226; See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 The power supplies have no power redundancy. • The 1400... describes the guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Combined Mode...
...8226; See Table 28-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 The power supplies have no power redundancy. • The 1400... describes the guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in a Catalyst 4500 series switch are less than the maximum available power for the chassis and inline power for the power supply. Combined Mode...
Software Guide
Page 424
...power requirements and verify that your system has enough power, add the power that is configurable. The chassis power includes power for the Catalyst 4500 series switches. Power Management Limitations This section describes the power-management limitations for the supervisor engine(s), all line ... Power Supplies Table 28-1 lists the power that is provided by the power supplies for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The backplane consumes 10 W in redundant mode. 4. The 1400 ...
...power requirements and verify that your system has enough power, add the power that is configurable. The chassis power includes power for the Catalyst 4500 series switches. Power Management Limitations This section describes the power-management limitations for the supervisor engine(s), all line ... Power Supplies Table 28-1 lists the power that is provided by the power supplies for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The backplane consumes 10 W in redundant mode. 4. The 1400 ...
Software Guide
Page 425
... the system, the power to the power supply status so that is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-5 The inline power is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400...
... the system, the power to the power supply status so that is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-5 The inline power is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines and restrictions for using a 1400...
Software Guide
Page 426
... in 1+1 redundancy mode) and four WS-X4148-RJ or WS-X4148-RJ21 modules • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with redundant power supplies, both power supplies should have different power requirements; The Catalyst 4000 series switch chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows...
... in 1+1 redundancy mode) and four WS-X4148-RJ or WS-X4148-RJ21 modules • One Catalyst 4006 chassis with a WS-X4013 supervisor engine with redundant power supplies, both power supplies should have different power requirements; The Catalyst 4000 series switch chassis supports only the 400 W AC, 400 W DC, and 650 W DC power supplies and allows...
Software Guide
Page 427
... evaluation cycle. Chapter 28 Power Management Understanding How Power Management Works on the Catalyst 4006 Switch If you choose to use a 1+1 redundancy configuration, you must carefully plan the configuration of the module power usage of your chassis. If you power down a chassis that has been operating in 1+1 redundancy mode with a valid module configuration and...
... evaluation cycle. Chapter 28 Power Management Understanding How Power Management Works on the Catalyst 4006 Switch If you choose to use a 1+1 redundancy configuration, you must carefully plan the configuration of the module power usage of your chassis. If you power down a chassis that has been operating in 1+1 redundancy mode with a valid module configuration and...
Software Guide
Page 428
...leaves the remaining modules in slots 4 and 5-90 W each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The evaluation process may require several cycles to resolve this configuration. • WS-X4013...reset mode. During the evaluation cycle, the modules are placed into service; The supervisor engine always remains enabled. If the chassis module combination and the modules in reset mode still require more evaluation cycles are placed in 1+1 redundancy mode for this ...
...leaves the remaining modules in slots 4 and 5-90 W each (600 W total) • Fan tray-25 W 28-8 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The evaluation process may require several cycles to resolve this configuration. • WS-X4013...reset mode. During the evaluation cycle, the modules are placed into service; The supervisor engine always remains enabled. If the chassis module combination and the modules in reset mode still require more evaluation cycles are placed in 1+1 redundancy mode for this ...
Software Guide
Page 430
... enabled on the Catalyst 4500 series switches; If you insert the supervisor engine into the Catalyst 4500 series chassis. This might affect the selection of the new switch becomes the bridge ID priority that you migrate your configuration and reload the configuration file after you can vary from a Catalyst 4006 switch to a Catalyst 4503 or 4506 switch, save your supervisor...
... enabled on the Catalyst 4500 series switches; If you insert the supervisor engine into the Catalyst 4500 series chassis. This might affect the selection of the new switch becomes the bridge ID priority that you migrate your configuration and reload the configuration file after you can vary from a Catalyst 4006 switch to a Catalyst 4503 or 4506 switch, save your supervisor...
Software Guide
Page 431
... connected to an AC power source and supply its own power to disable the detection mechanism. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can set each port...
... connected to an AC power source and supply its own power to disable the detection mechanism. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can set each port...
Software Guide
Page 437
...-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Chapter 28 Power Management Configuring Power Management This example shows how to set the power...
...-C45-1000AC Modem Baud Traffic Peak Peak-Time disable 9600 0% 0% Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Chapter 28 Power Management Configuring Power Management This example shows how to set the power...
Software Guide
Page 441
... Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
... Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
Software Guide
Page 555
... refers to these sections: • Understanding How Switch Acceleration Works, page 36-1 • Configuring Switch Acceleration on the Catalyst 4000 family supervisor engine. As a result, traffic coming in the chassis. • SE3 handles traffic for that port. Supervisor Engine II has three switch engines that are supported on the Switch, page 36-2 • Backplane Channel Module...
... refers to these sections: • Understanding How Switch Acceleration Works, page 36-1 • Configuring Switch Acceleration on the Catalyst 4000 family supervisor engine. As a result, traffic coming in the chassis. • SE3 handles traffic for that port. Supervisor Engine II has three switch engines that are supported on the Switch, page 36-2 • Backplane Channel Module...