Hardware Reference Guide - HP Pro 2000 and 3000 Series Microtower Business PCs
Page 38
... menu, select Advanced > Hood Sensor > Reset Case Open Status and make sure Enable is displayed to enter the Computer Setup menu. If the alarm sounds, close the access panel, tighten the thumbscrew, then reboot the system. The system will beep 5 times for 5 seconds. If the error message persists, press the F10... key immediately when the HP Logo screen is selected, then press the F10 key to Save and Exit, then reboot the system. 32 Hardware Upgrades Hood Sensor If the access panel is removed while there is still power to the computer, the hood ...
... menu, select Advanced > Hood Sensor > Reset Case Open Status and make sure Enable is displayed to enter the Computer Setup menu. If the alarm sounds, close the access panel, tighten the thumbscrew, then reboot the system. The system will beep 5 times for 5 seconds. If the error message persists, press the F10... key immediately when the HP Logo screen is selected, then press the F10 key to Save and Exit, then reboot the system. 32 Hardware Upgrades Hood Sensor If the access panel is removed while there is still power to the computer, the hood ...
Illustrated Parts & Service Map: HP Pro 3000/3080 Business PC Microtower Chassis
Page 3
..., and Fourth Boot Device Allows you are used. 2 short beeps and 1 long beep followed by a three second memory configura- Alarm PC Health Exit Chassis Allows you to disable/enable the chassis intrusion function Opened Warn- Setup Discard Allows you to exit Computer Setup without ...Replace the system board. 5 short beeps followed by a No CD found . 1. When you to proper version. 2. Remove the access panel. 4. Locate the header and jumper labeled CMOS. 5. Replace the access panel. 8. HP Pro 3000/3080 Illustrated Parts & Service Map, MT chassis 600836-001 page 3
..., and Fourth Boot Device Allows you are used. 2 short beeps and 1 long beep followed by a three second memory configura- Alarm PC Health Exit Chassis Allows you to disable/enable the chassis intrusion function Opened Warn- Setup Discard Allows you to exit Computer Setup without ...Replace the system board. 5 short beeps followed by a No CD found . 1. When you to proper version. 2. Remove the access panel. 4. Locate the header and jumper labeled CMOS. 5. Replace the access panel. 8. HP Pro 3000/3080 Illustrated Parts & Service Map, MT chassis 600836-001 page 3
Maintenance & Service Guide: HP Pro 3000/3010/3080 Business PCs
Page 92
...Open Status and make sure Enable is selected, then press the F10 key to enter the Computer Setup menu. Hood Sensor If the access panel is removed while there is still power to the computer, the hood sensor will cause the system to stop and display the Error 912 ... persists, press the F10 key immediately when the HP Logo screen is displayed to Save and Exit, then reboot the system. 82 Chapter 6 Removal and Replacement Procedures Microtower (MT) Chassis The system will beep 5 times for 5 seconds. If the alarm sounds, close the access panel, tighten the thumbscrew, then reboot the system.
...Open Status and make sure Enable is selected, then press the F10 key to enter the Computer Setup menu. Hood Sensor If the access panel is removed while there is still power to the computer, the hood sensor will cause the system to stop and display the Error 912 ... persists, press the F10 key immediately when the HP Logo screen is displayed to Save and Exit, then reboot the system. 82 Chapter 6 Removal and Replacement Procedures Microtower (MT) Chassis The system will beep 5 times for 5 seconds. If the alarm sounds, close the access panel, tighten the thumbscrew, then reboot the system.
Maintenance & Service Guide: HP Pro 3000/3010/3080 Business PCs
Page 142
Hood Sensor If the access panel is removed while there is displayed to enter the Computer Setup menu. If the error message persists, press the F10 key immediately when the HP Logo screen is still power to the computer, the hood sensor will cause the system to Save and Exit, then ...reboot the system. 132 Chapter 7 Removal and Replacement Procedures Small Form Factor (SFF) Chassis The system will beep 5 times for 5 seconds. If the alarm sounds, close the access panel, tighten...
Hood Sensor If the access panel is removed while there is displayed to enter the Computer Setup menu. If the error message persists, press the F10 key immediately when the HP Logo screen is still power to the computer, the hood sensor will cause the system to Save and Exit, then ...reboot the system. 132 Chapter 7 Removal and Replacement Procedures Small Form Factor (SFF) Chassis The system will beep 5 times for 5 seconds. If the alarm sounds, close the access panel, tighten...