Technical Guide
Page 8
...helps reduce or eliminate manual processes so less time and money is efficient, secure and user-friendly. The Dell OpenManage™ suite offers enhanced operations and standards-based commands designed to running fast. This helps eliminate the need to PowerEdge R610 and R810 Feature ...Processor Form Factor Front Side Bus # Sockets # Cores L2/L3 Cache Chipset DIMMs Min/Max RAM R610 Intel® Xeon® processor 5500 and 5600 series 1U rack Intel® QuickPath Interconnect (QPI) 2 2, 4, or 6 4MB, 8MB, and 12MB Intel® 5520 12 DDR3 1GB/192GB R710...
...helps reduce or eliminate manual processes so less time and money is efficient, secure and user-friendly. The Dell OpenManage™ suite offers enhanced operations and standards-based commands designed to running fast. This helps eliminate the need to PowerEdge R610 and R810 Feature ...Processor Form Factor Front Side Bus # Sockets # Cores L2/L3 Cache Chipset DIMMs Min/Max RAM R610 Intel® Xeon® processor 5500 and 5600 series 1U rack Intel® QuickPath Interconnect (QPI) 2 2, 4, or 6 4MB, 8MB, and 12MB Intel® 5520 12 DDR3 1GB/192GB R710...
Technical Guide
Page 16
... Indicators section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.4 Back Panel View and Features Figure 5 shows the back view of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.5 Power Supply Indicators The PowerEdge R710 redundant power supplies have one status bi-color LED: green...
... Indicators section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.4 Back Panel View and Features Figure 5 shows the back view of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.5 Power Supply Indicators The PowerEdge R710 redundant power supplies have one status bi-color LED: green...
Technical Guide
Page 17
... Power Indicator Codes section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.6 NIC Indicators See the NIC Indicator Codes section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.7 Internal Chassis Views Figure 6 shows the internal view...
... Power Indicator Codes section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.6 NIC Indicators See the NIC Indicator Codes section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information. 4.7 Internal Chassis Views Figure 6 shows the internal view...
Technical Guide
Page 20
... display. The system's LCD panel provides system information and status messages to the chassis. When in the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com. 4.11 Security For additional information regarding the following security features, see the PowerEdge R710 Hardware Owner's Manual on the server even when the power button is installed. 4.11.3 Hard Drive The optional front...
... display. The system's LCD panel provides system information and status messages to the chassis. When in the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com. 4.11 Security For additional information regarding the following security features, see the PowerEdge R710 Hardware Owner's Manual on the server even when the power button is installed. 4.11.3 Hard Drive The optional front...
Technical Guide
Page 21
...and indicates intrusion to store FRU data. 4.15 User Accessible Jumpers, Sockets, and Connectors See the Jumpers and Connectors chapter in the PowerEdge R710 Hardware Owner's Manual on the ICH9 chip. 4.14 Field Replaceable Units (FRU) The planar contains a serial EEPROM to detect chassis intrusion. When enabled... Setup. In addition, there is used to store Microsoft® BitLocker™ keys for the Real-Time Clock and CMOS RAM on Support.Dell.com. The TPM can provide notification that disables the power button function. 4.11.6 Intrusion Alert A switch mounted on the bezel...
...and indicates intrusion to store FRU data. 4.15 User Accessible Jumpers, Sockets, and Connectors See the Jumpers and Connectors chapter in the PowerEdge R710 Hardware Owner's Manual on the ICH9 chip. 4.14 Field Replaceable Units (FRU) The planar contains a serial EEPROM to detect chassis intrusion. When enabled... Setup. In addition, there is used to store Microsoft® BitLocker™ keys for the Real-Time Clock and CMOS RAM on Support.Dell.com. The TPM can provide notification that disables the power button function. 4.11.6 Intrusion Alert A switch mounted on the bezel...
Technical Guide
Page 29
...4.8GT/s 4.8GT/s 4.8GT/s 6.4 Processor Configurations 6.4.1 Single Processor Configuration The PowerEdge R710 is provided by EVRD (Enterprise Voltage Regulator-Down). PowerEdge R710 Technical Guide 29 EVRDs are embedded on Support.dell.com for processor installation and removal instructions. EVRDs support static phase shedding and ... a single processor placed in the Installing System Components chapter of the Dell PowerEdge R710 Systems Hardware Owner's Manual on the planar. If using a single processor, the R710 requires a heatsink blank in the CPU2 socket for thermal reasons. 6.4.2...
...4.8GT/s 4.8GT/s 4.8GT/s 6.4 Processor Configurations 6.4.1 Single Processor Configuration The PowerEdge R710 is provided by EVRD (Enterprise Voltage Regulator-Down). PowerEdge R710 Technical Guide 29 EVRDs are embedded on Support.dell.com for processor installation and removal instructions. EVRDs support static phase shedding and ... a single processor placed in the Installing System Components chapter of the Dell PowerEdge R710 Systems Hardware Owner's Manual on the planar. If using a single processor, the R710 requires a heatsink blank in the CPU2 socket for thermal reasons. 6.4.2...
Technical Guide
Page 33
...Independent Channel) mode, all three channels. Sparing requires identical memory installed in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.dell.com. One of the three channels is considered the Spare Channel, and two-thirds of 1 GB memory modules per processor is the amount reported during POST and in the Advanced...Memory section in the Installing System Components chapter in all three channels are combined to form one 128-bit channel. PowerEdge R710 Technical Guide 33 and x8based memory modules. Dell 7.7 Sparing Systems with x8-based memory modules.
...Independent Channel) mode, all three channels. Sparing requires identical memory installed in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.dell.com. One of the three channels is considered the Spare Channel, and two-thirds of 1 GB memory modules per processor is the amount reported during POST and in the Advanced...Memory section in the Installing System Components chapter in all three channels are combined to form one 128-bit channel. PowerEdge R710 Technical Guide 33 and x8based memory modules. Dell 7.7 Sparing Systems with x8-based memory modules.
Technical Guide
Page 39
...Support for customer installation of a full-length 12.2" PCI Express card in the Installing System Components chapter of the Dell PowerEdge R710 Systems Hardware Owner's Manual on third and fourth cards due to system thermal limitations) Optional x16 riser to the Expansion Cards and... priority, see the Expansion Cards and Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 11.4 Quantities and Priorities Refer to accommodate interface cards for three full-height 9.5‖-long PCI...
...Support for customer installation of a full-length 12.2" PCI Express card in the Installing System Components chapter of the Dell PowerEdge R710 Systems Hardware Owner's Manual on third and fourth cards due to system thermal limitations) Optional x16 riser to the Expansion Cards and... priority, see the Expansion Cards and Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 11.4 Quantities and Priorities Refer to accommodate interface cards for three full-height 9.5‖-long PCI...
Technical Guide
Page 40
Dell 11.5 PCI Card Dimensions For information about PCIe slots and card dimensions, see the Expansion Cards and Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. PowerEdge R710 Technical Guide 40
Dell 11.5 PCI Card Dimensions For information about PCIe slots and card dimensions, see the Expansion Cards and Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. PowerEdge R710 Technical Guide 40
Technical Guide
Page 42
... Configuration Support The system supports diskless configuration with no storage controller (SAS 6/iR, PERC 6i, PERC H200, or PERC H700) installed in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 12.3 RAID Configurations See Table 11 for information on the backplane. Config Type Table 11. Both LEDs are used to indicate certain...
... Configuration Support The system supports diskless configuration with no storage controller (SAS 6/iR, PERC 6i, PERC H200, or PERC H700) installed in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 12.3 RAID Configurations See Table 11 for information on the backplane. Config Type Table 11. Both LEDs are used to indicate certain...
Information Update
Page 1
... the supported memory configurations listed in the Hardware Owner's Manual at support.dell.com/manuals. For systems with two processors: • Single-rank and dual-rank RDIMMs of sizes 2 GB, 4 GB, 8 GB, and 16 GB are supported for a total of up to 288 GB. • Quad-rank RDIMMs (two per... modules: - One memory module per channel support up to 1333 MHz. - Three memory modules per channel supports up to 24 GB. Dell PowerEdge R710-Information Update System Memory This document provides latest information on your system configuration such as the processor series, DIMM voltage (low or...
... the supported memory configurations listed in the Hardware Owner's Manual at support.dell.com/manuals. For systems with two processors: • Single-rank and dual-rank RDIMMs of sizes 2 GB, 4 GB, 8 GB, and 16 GB are supported for a total of up to 288 GB. • Quad-rank RDIMMs (two per... modules: - One memory module per channel support up to 1333 MHz. - Three memory modules per channel supports up to 24 GB. Dell PowerEdge R710-Information Update System Memory This document provides latest information on your system configuration such as the processor series, DIMM voltage (low or...