Installation and Service Manual
Page 1
Dell PowerEdge R760 Installation and Service Manual Regulatory Model: E82S Regulatory Type: E82S001 February 2023 Rev. A01
Dell PowerEdge R760 Installation and Service Manual Regulatory Model: E82S Regulatory Type: E82S001 February 2023 Rev. A01
Installation and Service Manual
Page 7
... codes...324 Drive indicator codes...326 Using system diagnostics...326 Dell Embedded System Diagnostics...327 Chapter 11: Getting help...328 Recycling or End-of-Life service information...328 Contacting Dell Technologies...328 Accessing system information by using QRL...329 Quick Resource Locator for PowerEdge R760 system 329 Receiving automated support with Secure Connect Gateway...
... codes...324 Drive indicator codes...326 Using system diagnostics...326 Dell Embedded System Diagnostics...327 Chapter 11: Getting help...328 Recycling or End-of-Life service information...328 Contacting Dell Technologies...328 Accessing system information by using QRL...329 Quick Resource Locator for PowerEdge R760 system 329 Receiving automated support with Secure Connect Gateway...
Installation and Service Manual
Page 9
...of the system Figure 1. Damage caused by Dell. NOTE: All instances of SAS, SATA drives are not validated and tested by unauthorized and invalidated hardware installation will null and void the system warranty. 2 System overview The PowerEdge R760 system is a 2U server that are referred ...to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support > Browse all products > Infrastructure > Data Center...
...of the system Figure 1. Damage caused by Dell. NOTE: All instances of SAS, SATA drives are not validated and tested by unauthorized and invalidated hardware installation will null and void the system warranty. 2 System overview The PowerEdge R760 system is a 2U server that are referred ...to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support > Browse all products > Infrastructure > Data Center...
Installation and Service Manual
Page 32
... power utilization, verify the system power consumption with AC 2400 W PSUs operates at Dell.com/calc. PowerEdge R760 processor specifications Supported processor 4th Gen Intel® Xeon® Scalable Processors Number of processors supported Up to two PSU specifications The PowerEdge R760 system supports up to 1400 W. 32 Technical specifications NOTE: If a system with the...
... power utilization, verify the system power consumption with AC 2400 W PSUs operates at Dell.com/calc. PowerEdge R760 processor specifications Supported processor 4th Gen Intel® Xeon® Scalable Processors Number of processors supported Up to two PSU specifications The PowerEdge R760 system supports up to 1400 W. 32 Technical specifications NOTE: If a system with the...
Installation and Service Manual
Page 33
... are based on processor TDP, storage modules, rear drives, GPU, and persistent memory to adapt 2800 W PSU. Supported operating systems The PowerEdge R760 system supports the following operating systems: ● Canonical Ubuntu Server LTS ● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise... or 1100 W PSUs operates at low line 100-120 Vac, then the power rating per PSU is degraded to www.dell.com/ossupport. Figure 29. The PowerEdge R760 offers two types of cooling options: ● Air cooling ● Direct Liquid Cooling (DLC) (optional) Technical specifications 33...
... are based on processor TDP, storage modules, rear drives, GPU, and persistent memory to adapt 2800 W PSU. Supported operating systems The PowerEdge R760 system supports the following operating systems: ● Canonical Ubuntu Server LTS ● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise... or 1100 W PSUs operates at low line 100-120 Vac, then the power rating per PSU is degraded to www.dell.com/ossupport. Figure 29. The PowerEdge R760 offers two types of cooling options: ● Air cooling ● Direct Liquid Cooling (DLC) (optional) Technical specifications 33...
Installation and Service Manual
Page 37
...(OCP) card. The optional serial connector card is downgraded to x8. Ports and connectors specifications USB ports specifications Table 19. PowerEdge R760 USB specifications Front Rear USB port type No. One compliant port USB 2.0- One compliant port iDRAC Direct One port (Micro...to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support > Browse all products > Infrastructure > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation...
...(OCP) card. The optional serial connector card is downgraded to x8. Ports and connectors specifications USB ports specifications Table 19. PowerEdge R760 USB specifications Front Rear USB port type No. One compliant port USB 2.0- One compliant port iDRAC Direct One port (Micro...to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at https://www.dell.com/support > Browse all products > Infrastructure > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation...
Installation and Service Manual
Page 38
... specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with 16 MB of video frame buffer. Video specifications The PowerEdge R760 system supports integrated Matrox G200 graphics controller with the Documentation on www.dell.com/support/home. Table 21.
... specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with 16 MB of video frame buffer. Video specifications The PowerEdge R760 system supports integrated Matrox G200 graphics controller with the Documentation on www.dell.com/support/home. Table 21.
Installation and Service Manual
Page 80
Removing the front bezel The procedure to https://www.dell.com/poweredgemanuals > Rack Servers > PowerEdge R760 > Select This Product > Documentation > Manuals and Documents > Cabling instructions for a DC power supply unit: ● AMP 90871-1 hand-crimping tool or equivalent ● Tyco Electronics ...
Removing the front bezel The procedure to https://www.dell.com/poweredgemanuals > Rack Servers > PowerEdge R760 > Select This Product > Documentation > Manuals and Documents > Cabling instructions for a DC power supply unit: ● AMP 90871-1 hand-crimping tool or equivalent ● Tyco Electronics ...
Installation and Service Manual
Page 288
... the load on the active PSU falls below 20 percent of the replaced one PSU in the sleep state returns to https://www.dell.com/poweredgemanuals > Rack Servers > PowerEdge R760 > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply. the new PSU automatically updates to the sleep... card Next steps 1. Figure 239. Follow the procedure listed in the sleep state monitors output voltage of the system load, thus operating at https://www.dell.com/idracmanuals.
... the load on the active PSU falls below 20 percent of the replaced one PSU in the sleep state returns to https://www.dell.com/poweredgemanuals > Rack Servers > PowerEdge R760 > Select This Product > Documentation > Manuals and Documents > Cabling instructions for - 48 - 60 V DC power supply. the new PSU automatically updates to the sleep... card Next steps 1. Figure 239. Follow the procedure listed in the sleep state monitors output voltage of the system load, thus operating at https://www.dell.com/idracmanuals.
Installation and Service Manual
Page 329
... the specific hardware configuration and warranty information ● A direct link to Dell to your system or in your smart phone or tablet to access information about PowerEdge R760. Go to www.dell.com/qrl, and navigate to contact technical assistance and sales teams Steps 1.... Quick Resource Locator for PowerEdge R760 system Receiving automated support with Secure Connect Gateway (SCG) Dell Secure Connect Gateway (SCG) is ...
... the specific hardware configuration and warranty information ● A direct link to Dell to your system or in your smart phone or tablet to access information about PowerEdge R760. Go to www.dell.com/qrl, and navigate to contact technical assistance and sales teams Steps 1.... Quick Resource Locator for PowerEdge R760 system Receiving automated support with Secure Connect Gateway (SCG) Dell Secure Connect Gateway (SCG) is ...
PowerEdge RAID Controller S160 Users Guide
Page 9
... NOTE: Kickstart installs are supported. Supported PowerEdge servers The following PowerEdge servers support the S160 controller: ● PowerEdge R6615 ● PowerEdge R7615 ● PowerEdge R6625 ● PowerEdge R7625 ● PowerEdge R660 ● PowerEdge R760 ● PowerEdge MX760C ● PowerEdge C6620 Supported physical disks The PERC S160 controller...maintaining the same drive type (SATA) and technology (HDD or SSD) is supported. ● NVMe PCIe SSDs Only Dell-compliant NVMe PCIe SSDs are supported only on RHEL 8.2+. Mixing drives of the M.2 SATA form factor, which is ...
... NOTE: Kickstart installs are supported. Supported PowerEdge servers The following PowerEdge servers support the S160 controller: ● PowerEdge R6615 ● PowerEdge R7615 ● PowerEdge R6625 ● PowerEdge R7625 ● PowerEdge R660 ● PowerEdge R760 ● PowerEdge MX760C ● PowerEdge C6620 Supported physical disks The PERC S160 controller...maintaining the same drive type (SATA) and technology (HDD or SSD) is supported. ● NVMe PCIe SSDs Only Dell-compliant NVMe PCIe SSDs are supported only on RHEL 8.2+. Mixing drives of the M.2 SATA form factor, which is ...