EMC Boot Optimized Server Storage-S1 Users Guide
Page 3
Contents Chapter 1: Overview...5 Supported operating systems...6 Supported PowerEdge systems ...6 BOSS-S1 card specifications...7 Supported M.2 drives...7 Management applications for the BOSS-S1 controller...8 Update the BOSS-S1 controller...8 Update the BOSS-S1 firmware...8 ... M.2 SSD module from the BOSS-S1 card 15 Installing the M.2 SSD module on BOSS-S1 card...16 Installing the BOSS-S1 card...17 Chapter 4: Driver installation...19 Chapter 5: UEFI or HII RAID configuration utility 20 Entering the UEFI configuration utility...20 Exiting the UEFI configuration utility...20 Entering the BOSS...
Contents Chapter 1: Overview...5 Supported operating systems...6 Supported PowerEdge systems ...6 BOSS-S1 card specifications...7 Supported M.2 drives...7 Management applications for the BOSS-S1 controller...8 Update the BOSS-S1 controller...8 Update the BOSS-S1 firmware...8 ... M.2 SSD module from the BOSS-S1 card 15 Installing the M.2 SSD module on BOSS-S1 card...16 Installing the BOSS-S1 card...17 Chapter 4: Driver installation...19 Chapter 5: UEFI or HII RAID configuration utility 20 Entering the UEFI configuration utility...20 Exiting the UEFI configuration utility...20 Entering the BOSS...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 6
... operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○... 3 ○ ESXi 6.7 Update 2 ○ ESXi 6.7 Update 1 ○ ESXi 6.7 NOTE: For the latest list of supported operating systems and driver installation instructions, see the Drivers and Downloads section at www.dell.com/operatingsystemmanuals.
... operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○... 3 ○ ESXi 6.7 Update 2 ○ ESXi 6.7 Update 1 ○ ESXi 6.7 NOTE: For the latest list of supported operating systems and driver installation instructions, see the Drivers and Downloads section at www.dell.com/operatingsystemmanuals.
EMC Boot Optimized Server Storage-S1 Users Guide
Page 8
...single graphical or command-line interface. The BOSS-S1 CLI Utility also supports ESXi. You can download the latest Windows unified console driver from www.dell.com/ support/home. Windows systems use the mvsetup utility while Linux systems use the BOSS-S1 card only as an operating ...see BOSS-S1 CLI commands on page 24. NOTE: To use the mvsetup Windows utility, the BOSS-S1 management driver must first be updated using the following methods: • Operating system Dell Update Packages • UEFI Shell • BOSS-S1 CLI • iDRAC • Lifecycle Controller 8 Overview...
...single graphical or command-line interface. The BOSS-S1 CLI Utility also supports ESXi. You can download the latest Windows unified console driver from www.dell.com/ support/home. Windows systems use the mvsetup utility while Linux systems use the BOSS-S1 card only as an operating ...see BOSS-S1 CLI commands on page 24. NOTE: To use the mvsetup Windows utility, the BOSS-S1 management driver must first be updated using the following methods: • Operating system Dell Update Packages • UEFI Shell • BOSS-S1 CLI • iDRAC • Lifecycle Controller 8 Overview...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 19
... www.dell.com/support/home. Linux driver installation - A DUP supports command line interface and silent execution. By default, native AHCI driver is an executable application that updates drivers for specific devices. ESXi driver installation - Driver installation 19 4 Driver installation The BOSS-S1 card uses the native AHCI driver of the supported operating systems. Windows driver installation - The Driver Update Package...
... www.dell.com/support/home. Linux driver installation - A DUP supports command line interface and silent execution. By default, native AHCI driver is an executable application that updates drivers for specific devices. ESXi driver installation - Driver installation 19 4 Driver installation The BOSS-S1 card uses the native AHCI driver of the supported operating systems. Windows driver installation - The Driver Update Package...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 26
Corrective Action: This issue is disabled on the 14th generation of PowerEdge systems that are not impacted by this issue. BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 Issue: When upgrading from iDRAC fails on unconfigured drives with an ...manager Issue: Importing BOSS ESXi CLI offline bundle into vSphere Lifecycle Manager fails through the vSphere Web Client. Corrective Action: Remove the driver packages before attempting an upgrade using iDRAC or LC fails • Physical disk size not updated in iDRAC • Physical disk/...
Corrective Action: This issue is disabled on the 14th generation of PowerEdge systems that are not impacted by this issue. BOSS ESXi CLI package fails when upgrading from Dell EMC customized versions of 6.7.x to version 7.0 Issue: When upgrading from iDRAC fails on unconfigured drives with an ...manager Issue: Importing BOSS ESXi CLI offline bundle into vSphere Lifecycle Manager fails through the vSphere Web Client. Corrective Action: Remove the driver packages before attempting an upgrade using iDRAC or LC fails • Physical disk size not updated in iDRAC • Physical disk/...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 27
... of M.2 drive on unconfigured drives in iDRAC interface Issue: Starting with an existing adapter key. NOTE: The ESXi must be gracefully rebooted to complete the driver packages removal before updating the firmware of M.2 drives using the iDRAC web interface fails when the drive is in the Linux operating system. Therefore, iDRAC...
... of M.2 drive on unconfigured drives in iDRAC interface Issue: Starting with an existing adapter key. NOTE: The ESXi must be gracefully rebooted to complete the driver packages removal before updating the firmware of M.2 drives using the iDRAC web interface fails when the drive is in the Linux operating system. Therefore, iDRAC...
EMC Systems Management Overview Guide Version 20.0
Page 15
...Windows Server and Hyper-V, Storage Spaces Direct Ready Nodes for Microsoft System Center Virtual Machine Manager Dell EMC server PRO Management Pack integrates PowerEdge server knowledge on bare-metal Dell EMC Ready Nodes Servers in -box tool, browser-based console to End deployment with the... • Performing compliance check for the hardware environment using the following options: ○ iDRAC with or without utilizing the LC driver packs based on the selected Golden Configuration and also replicate BIOS, RAID, and Boot Order settings. • Installing server operating systems...
...Windows Server and Hyper-V, Storage Spaces Direct Ready Nodes for Microsoft System Center Virtual Machine Manager Dell EMC server PRO Management Pack integrates PowerEdge server knowledge on bare-metal Dell EMC Ready Nodes Servers in -box tool, browser-based console to End deployment with the... • Performing compliance check for the hardware environment using the following options: ○ iDRAC with or without utilizing the LC driver packs based on the selected Golden Configuration and also replicate BIOS, RAID, and Boot Order settings. • Installing server operating systems...
Event and Error Message Reference Guide for EMC PowerEdge Servers
Page 6
... physical disk drive errors, and virtual drive errors. • Configuration: Represents alerts that are generated because of firmware or driver upgrades and downgrades. Intended audience This Error and Event Message reference guide is intended for system administrators and other users involved in... managing and troubleshooting Dell EMC Enterprise systems. For quick and easy reference, this guide is available on mobile devices also. 6 Introduction Examples include...
... physical disk drive errors, and virtual drive errors. • Configuration: Represents alerts that are generated because of firmware or driver upgrades and downgrades. Intended audience This Error and Event Message reference guide is intended for system administrators and other users involved in... managing and troubleshooting Dell EMC Enterprise systems. For quick and easy reference, this guide is available on mobile devices also. 6 Introduction Examples include...
Lifecycle Controller Version Remote Services Quick Start Guide
Page 4
...which enables efficient administration as part of the integrated Dell Remote Access Controller (iDRAC) out-of the hardware, including component and subsystem management that embeds systems management features and Operating System device drivers directly on the industry standard interfaces such as configuring... remote servers to servicing - It is delivered as server deployments scale. iDRAC works with Lifecycle Controller technology in the latest Dell servers. Also, it provides a single view of management functions that can be used by applications and scripts. Together, iDRAC...
...which enables efficient administration as part of the integrated Dell Remote Access Controller (iDRAC) out-of the hardware, including component and subsystem management that embeds systems management features and Operating System device drivers directly on the industry standard interfaces such as configuring... remote servers to servicing - It is delivered as server deployments scale. iDRAC works with Lifecycle Controller technology in the latest Dell servers. Also, it provides a single view of management functions that can be used by applications and scripts. Together, iDRAC...
Lifecycle Controller Version Remote Services Quick Start Guide
Page 5
...PowerEdge servers. On 12th, 13th, and 14th generation of PowerEdge servers, the vFlash feature is delivered as provisioning, deployment, and update from a unified interface • Automatic download of the required drivers and firmware to utilize the WSMan API provided by the integrated Dell.... The available licenses are split between multiple tools. Benefits of using Lifecycle Controller-Remote Services: • Install operating systems and drivers • Manage licensing • Perform server firmware update including IDSDM, NVDIMM, BOSS adapters, BIOS, iDRAC/LC, backplane and ...
...PowerEdge servers. On 12th, 13th, and 14th generation of PowerEdge servers, the vFlash feature is delivered as provisioning, deployment, and update from a unified interface • Automatic download of the required drivers and firmware to utilize the WSMan API provided by the integrated Dell.... The available licenses are split between multiple tools. Benefits of using Lifecycle Controller-Remote Services: • Install operating systems and drivers • Manage licensing • Perform server firmware update including IDSDM, NVDIMM, BOSS adapters, BIOS, iDRAC/LC, backplane and ...
EMC PowerEdge RAID Controller S150 Users Guide
Page 4
...UEFI RAID configuration utility 26 Entering the DELL PERC S150 Configuration Utility...26 Exiting the DELL PERC S150 Configuration Utility...27 Controller management...27 Virtual disk management...29 Physical disk management...34 Chapter 7: Installing the drivers...38 Pre-installation requirements...38 Setting ...and the boot list priority 39 Creating the device driver media for Windows driver installation 40 Downloading drivers for PERC S150 from the Dell support website for all operating systems 40 Downloading drivers from the Dell Systems Service and Diagnostic Tools media for Windows 40...
...UEFI RAID configuration utility 26 Entering the DELL PERC S150 Configuration Utility...26 Exiting the DELL PERC S150 Configuration Utility...27 Controller management...27 Virtual disk management...29 Physical disk management...34 Chapter 7: Installing the drivers...38 Pre-installation requirements...38 Setting ...and the boot list priority 39 Creating the device driver media for Windows driver installation 40 Downloading drivers for PERC S150 from the Dell support website for all operating systems 40 Downloading drivers from the Dell Systems Service and Diagnostic Tools media for Windows 40...
EMC PowerEdge RAID Controller S150 Users Guide
Page 5
...working...49 Cannot update NVMe PCIe SSD firmware by using a third party RAID configuration utility 54 Chapter 9: Getting help...55 Contacting Dell...55 Locating the Express Service Code and Service Tag...55 Related documentation...56 Documentation feedback...56 Contents 5 Related errors...49 S150 ...degraded virtual disk ...53 Cannot create a virtual disk on NVMe PCIe SSD using Dell Update Package or DUP 49 NVMe drive error when inserted for the first time 49 Third-party driver installation for operating system installation 49 Virtual disks - Found virtual disks that are degraded...
...working...49 Cannot update NVMe PCIe SSD firmware by using a third party RAID configuration utility 54 Chapter 9: Getting help...55 Contacting Dell...55 Locating the Express Service Code and Service Tag...55 Related documentation...56 Documentation feedback...56 Contents 5 Related errors...49 S150 ...degraded virtual disk ...53 Cannot create a virtual disk on NVMe PCIe SSD using Dell Update Package or DUP 49 NVMe drive error when inserted for the first time 49 Third-party driver installation for operating system installation 49 Virtual disks - Found virtual disks that are degraded...
EMC PowerEdge RAID Controller S150 Users Guide
Page 9
...For more information, see the Drivers and Downloads section at www.dell.com/support/drivers. Supported PowerEdge systems The following PowerEdge systems support the S150 controller: • PowerEdge R6515 • PowerEdge R7515 • PowerEdge R6525 • PowerEdge R7525 • PowerEdge C6525 Supported physical disks The ... (SATA) and technology (HDD or SSD) is supported. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the OpenManage Storage Management User's Guide at www.dell.com/openmanagemanuals. • Lifecycle Controller-This is a management application for all supported...
...For more information, see the Drivers and Downloads section at www.dell.com/support/drivers. Supported PowerEdge systems The following PowerEdge systems support the S150 controller: • PowerEdge R6515 • PowerEdge R7515 • PowerEdge R6525 • PowerEdge R7525 • PowerEdge C6525 Supported physical disks The ... (SATA) and technology (HDD or SSD) is supported. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the OpenManage Storage Management User's Guide at www.dell.com/openmanagemanuals. • Lifecycle Controller-This is a management application for all supported...
EMC PowerEdge RAID Controller S150 Users Guide
Page 12
...information about managing the physical disk write cache policy, see Configuring Linux RAID on all Sirius PowerEdge systems. You can download the latest BIOS firmware from NVMe virtual disk is not supported on...boot virtual disks are configured in UEFI mode. NOTE: RAID configuration and boot from www.dell.com/support. For more information about configuring Linux RAID, see Managing the physical disk ... RAID The Linux RAID feature is written to the Linux environment, the Linux native RAID driver manages the virtual disk. NOTE: Ensure that your system has the latest BIOS firmware. ...
...information about managing the physical disk write cache policy, see Configuring Linux RAID on all Sirius PowerEdge systems. You can download the latest BIOS firmware from NVMe virtual disk is not supported on...boot virtual disks are configured in UEFI mode. NOTE: RAID configuration and boot from www.dell.com/support. For more information about configuring Linux RAID, see Managing the physical disk ... RAID The Linux RAID feature is written to the Linux environment, the Linux native RAID driver manages the virtual disk. NOTE: Ensure that your system has the latest BIOS firmware. ...
EMC PowerEdge RAID Controller S150 Users Guide
Page 14
...data for cache. It is assigned for virtual disks. The CC operation reports data inconsistencies through Ctrl + R), the PERC S150 drivers must be initiated using Ctrl + R. The PERC S150 uses part of a BGI operation. BGI allows a redundant virtual disk to... most recent checkpoint. Three types of a redundant virtual disk creates the parity data that might occur with the redundant data at www.dell.com/openmanagemanuals. A CC cannot be used immediately. Background initialization Background initialization (BGI) of checkpointing are available: • Consistency Check ...
...data for cache. It is assigned for virtual disks. The CC operation reports data inconsistencies through Ctrl + R), the PERC S150 drivers must be initiated using Ctrl + R. The PERC S150 uses part of a BGI operation. BGI allows a redundant virtual disk to... most recent checkpoint. Three types of a redundant virtual disk creates the parity data that might occur with the redundant data at www.dell.com/openmanagemanuals. A CC cannot be used immediately. Background initialization Background initialization (BGI) of checkpointing are available: • Consistency Check ...
EMC PowerEdge RAID Controller S150 Users Guide
Page 27
... available on the system Displays the total number of virtual disks available Displays the UEFI driver version installed on the screen. In the System Setup Main Menu, click Device Settings > Dell PERC S150 Configuration Utility > Controller Management > View Controller Information. The table explains the... Setup screen, click Finish in the bottom-right corner on the system UEFI RAID configuration utility 27 Dell PERC S150 Configuration Utility Exiting the DELL PERC S150 Configuration Utility To exit the utility and return to view your controller and firmware properties. Figure 3....
... available on the system Displays the total number of virtual disks available Displays the UEFI driver version installed on the screen. In the System Setup Main Menu, click Device Settings > Dell PERC S150 Configuration Utility > Controller Management > View Controller Information. The table explains the... Setup screen, click Finish in the bottom-right corner on the system UEFI RAID configuration utility 27 Dell PERC S150 Configuration Utility Exiting the DELL PERC S150 Configuration Utility To exit the utility and return to view your controller and firmware properties. Figure 3....
EMC PowerEdge RAID Controller S150 Users Guide
Page 38
...system. 2. Click NVMe Settings. 5. If required, download the latest BIOS, firmware, and driver updates from www.dell.com/support/home. • Create a device driver media (USB drive, CD, or DVD). When the Dell PowerEdge System window is set to RAID mode will cause a data loss in BIOS settings. Press... Esc to SATA Settings and press Enter. Turn on the system. 2. NOTE: If necessary, use the space bar to RAID mode 1. 7 Installing the drivers The PowerEdge RAID Controller (PERC...
...system. 2. Click NVMe Settings. 5. If required, download the latest BIOS, firmware, and driver updates from www.dell.com/support/home. • Create a device driver media (USB drive, CD, or DVD). When the Dell PowerEdge System window is set to RAID mode will cause a data loss in BIOS settings. Press... Esc to SATA Settings and press Enter. Turn on the system. 2. NOTE: If necessary, use the space bar to RAID mode 1. 7 Installing the drivers The PowerEdge RAID Controller (PERC...
EMC PowerEdge RAID Controller S150 Users Guide
Page 39
..., ensure the bootable virtual disk is enabled only if the system contains a RAID Capable physical disk. 2. Select Continue to Non RAID, ensure that the NVMe driver (Microsoft or third-party NVMe driver) is not the first virtual disk listed, see Creating the virtual disks on page 22. Installing the... drivers 39 If the bootable virtual disk is installed manually in BIOS NOTE: If you change the NVMe Mode setting from RAID to Boot and press ...
..., ensure the bootable virtual disk is enabled only if the system contains a RAID Capable physical disk. 2. Select Continue to Non RAID, ensure that the NVMe driver (Microsoft or third-party NVMe driver) is not the first virtual disk listed, see Creating the virtual disks on page 22. Installing the... drivers 39 If the bootable virtual disk is installed manually in BIOS NOTE: If you change the NVMe Mode setting from RAID to Boot and press ...
EMC PowerEdge RAID Controller S150 Users Guide
Page 40
... a CD, DVD, or USB drive. Extract the content. 40 Installing the drivers The drivers that you created with the installation: a. Click OK. Close the warning window. c. The Welcome to Dell Service and Diagnostic Utilities screen is installed to your system model and operating system.... tag of supported operating systems, see the operating system document at www.dell.com/operatingsystemmanuals. For more information on reinstalling the operating system, see the relevant section for Windows 1. Downloading drivers from the Product Selection page. 3. For the list of your operating...
... a CD, DVD, or USB drive. Extract the content. 40 Installing the drivers The drivers that you created with the installation: a. Click OK. Close the warning window. c. The Welcome to Dell Service and Diagnostic Utilities screen is installed to your system model and operating system.... tag of supported operating systems, see the operating system document at www.dell.com/operatingsystemmanuals. For more information on reinstalling the operating system, see the relevant section for Windows 1. Downloading drivers from the Product Selection page. 3. For the list of your operating...
EMC PowerEdge RAID Controller S150 Users Guide
Page 41
The driver files will be installed by right clicking the .inf file. Installing the drivers 41 NOTE: S150 I/O driver name is bcraid .sys, where xyz is bcraid603.sys. For example, if the version is 6.0.3.0007, driver name is the first three digits of the driver version. The diver can be visible in the extracted folder.
The driver files will be installed by right clicking the .inf file. Installing the drivers 41 NOTE: S150 I/O driver name is bcraid .sys, where xyz is bcraid603.sys. For example, if the version is 6.0.3.0007, driver name is the first three digits of the driver version. The diver can be visible in the extracted folder.