EMC Boot Optimized Server Storage-S1 Users Guide
Page 8
... that M.2 drives have installed the latest firmware version available at Dell.com/support. The management applications for the BOSS-S1 controller Management applications enable you to effectively monitor the RAID and network controllers installed on the system using the BOSS-S1 command line interface (CLI) utility and Dell Update Package (DUP) when booted to check SMART information of the physical disks and display controller. For more information, see the Dell OpenManage Storage Management User's Guide at www.dell.com/idracmanuals. NOTE: Systems Management through...
... that M.2 drives have installed the latest firmware version available at Dell.com/support. The management applications for the BOSS-S1 controller Management applications enable you to effectively monitor the RAID and network controllers installed on the system using the BOSS-S1 command line interface (CLI) utility and Dell Update Package (DUP) when booted to check SMART information of the physical disks and display controller. For more information, see the Dell OpenManage Storage Management User's Guide at www.dell.com/idracmanuals. NOTE: Systems Management through...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 9
..., the installed version and package version are displayed. 5. Firmware update using Linux DUP Perform the following steps to update your system configuration. To continue press Y+Enter or N+Enter to flash the firmware. 6. Reboot the system from the USB drive, and go to UEFI. 4. Firmware update using UEFI Shell Perform the following steps to update using Linux: NOTE: Ensure that you have Administrator privileges for Linux from the www.dell.com/support/home. 2. Download the latest modular operating system...
..., the installed version and package version are displayed. 5. Firmware update using Linux DUP Perform the following steps to update your system configuration. To continue press Y+Enter or N+Enter to flash the firmware. 6. Reboot the system from the USB drive, and go to UEFI. 4. Firmware update using UEFI Shell Perform the following steps to update using Linux: NOTE: Ensure that you have Administrator privileges for Linux from the www.dell.com/support/home. 2. Download the latest modular operating system...
EMC PowerEdge RAID Controller S140 Users Guide
Page 4
... PCIe SSDs to RAID mode ...38 Creating a virtual disk...39 Checking PERC S140 options and the boot list priority 39 Creating the device driver media for Windows driver installation 40 Downloading drivers for PERC S140 from the Dell support website for all operating systems 40 Downloading drivers from the Dell Systems Service and Diagnostic Tools media for Windows 40 Accessing ZP files...40 Chapter 8: Troubleshooting your system 42 Precautions for hot removal or hot insertion of NVMe drives 42 Unable to configure Linux RAID using UEFI Configuration Utility...
... PCIe SSDs to RAID mode ...38 Creating a virtual disk...39 Checking PERC S140 options and the boot list priority 39 Creating the device driver media for Windows driver installation 40 Downloading drivers for PERC S140 from the Dell support website for all operating systems 40 Downloading drivers from the Dell Systems Service and Diagnostic Tools media for Windows 40 Accessing ZP files...40 Chapter 8: Troubleshooting your system 42 Precautions for hot removal or hot insertion of NVMe drives 42 Unable to configure Linux RAID using UEFI Configuration Utility...
EMC PowerEdge RAID Controller S140 Users Guide
Page 5
... PowerEdge R740 48 Cannot update NVMe PCIe SSD firmware by using a third party RAID configuration utility 52 Chapter 9: Getting help...53 Contents 5 Found virtual disks that are degraded 45 WARNING - Related errors...49 Virtual disk size in decimals is not supported while creating a VD 49 Cannot create a virtual disk...49 A virtual disk is observed while booting on the NVMe configuration server 46 Failure of SAMSUNG 1733 or 1735 drives ...46 Other errors appearing on the BIOS...
... PowerEdge R740 48 Cannot update NVMe PCIe SSD firmware by using a third party RAID configuration utility 52 Chapter 9: Getting help...53 Contents 5 Found virtual disks that are degraded 45 WARNING - Related errors...49 Virtual disk size in decimals is not supported while creating a VD 49 Cannot create a virtual disk...49 A virtual disk is observed while booting on the NVMe configuration server 46 Failure of SAMSUNG 1733 or 1735 drives ...46 Other errors appearing on the BIOS...
EMC PowerEdge RAID Controller S140 Users Guide
Page 13
... not have to support Samsung PM1733 and PM1735 drives is S140 5.5.2.8. Fault tolerance The following fault tolerance features are factors related to a new replacement physical disk configured as a hot spare. Native Command Queuing Native Command Queuing (NCQ) is a command protocol used to restore the data to read from the Dell EMC open manage console. NOTE: Hot removal or hot insertion of a RAID 1 (mirror) fails, data can be rebuilt by SATA physical disks supported on the other...
... not have to support Samsung PM1733 and PM1735 drives is S140 5.5.2.8. Fault tolerance The following fault tolerance features are factors related to a new replacement physical disk configured as a hot spare. Native Command Queuing Native Command Queuing (NCQ) is a command protocol used to restore the data to read from the Dell EMC open manage console. NOTE: Hot removal or hot insertion of a RAID 1 (mirror) fails, data can be rebuilt by SATA physical disks supported on the other...
EMC PowerEdge RAID Controller S140 Users Guide
Page 38
.... Turn on RAID mode. 1. Setting the NVMe PCIe SSDs to RAID mode WARNING: Changing mode to RAID mode 1. NOTE: Ensure SATA settings is displayed, press F2. 3. Click NVMe Settings. 5. Select RAID mode. 6. When the Dell PowerEdge System window is displayed, click System BIOS. 4. When the Dell Power-On Self-Test (POST) screen is on the system. 2. NOTE: To check operating system compatibility, see www.dell.com/manuals. If required, download the latest BIOS, firmware, and driver updates from dell.com/support. • Create a device driver media (USB drive, CD, or DVD). 7 Installing...
.... Turn on RAID mode. 1. Setting the NVMe PCIe SSDs to RAID mode WARNING: Changing mode to RAID mode 1. NOTE: Ensure SATA settings is displayed, press F2. 3. Click NVMe Settings. 5. Select RAID mode. 6. When the Dell PowerEdge System window is displayed, click System BIOS. 4. When the Dell Power-On Self-Test (POST) screen is on the system. 2. NOTE: To check operating system compatibility, see www.dell.com/manuals. If required, download the latest BIOS, firmware, and driver updates from dell.com/support. • Create a device driver media (USB drive, CD, or DVD). 7 Installing...
EMC Systems Management Overview Guide Version 20.0
Page 9
... BIOS, iDRAC, PERC, NIC, and HBA settings as well as firmware RACADM; RACADM also supports profile-based server configuration management, detailed hardware and firmware inventory, and access to MX7000 remotely happens through OpenManage Enterprise console OMM can configure IP addresses, view server inventory, health status and logs, or power cycle a server. OpenManage Ansible Modules Dell EMC OpenManage Ansible Modules enable data center and IT administrators to use Red Hat Ansible to perform inventory, configuration, update, and health status check of PowerEdge Servers. It uses...
... BIOS, iDRAC, PERC, NIC, and HBA settings as well as firmware RACADM; RACADM also supports profile-based server configuration management, detailed hardware and firmware inventory, and access to MX7000 remotely happens through OpenManage Enterprise console OMM can configure IP addresses, view server inventory, health status and logs, or power cycle a server. OpenManage Ansible Modules Dell EMC OpenManage Ansible Modules enable data center and IT administrators to use Red Hat Ansible to perform inventory, configuration, update, and health status check of PowerEdge Servers. It uses...
EMC Systems Management Overview Guide Version 20.0
Page 10
..., storage, and networking. the iDRAC, OpenManage Enterprise, and OpenManage Enterprise Modular. Ansible is a unified web/RESTful API interface that can enable and disable features on iSM by the iDRAC interfaces to control the CPU and memory consumed on (SSO) to use the iDRAC RESTful API for PowerEdge servers, data center and IT administrators can rapidly deploy their fingertips. Chassis and server managers Integrated Dell Remote Access Controller The integrated Dell Remote Access Controller 9 (iDRAC9...
..., storage, and networking. the iDRAC, OpenManage Enterprise, and OpenManage Enterprise Modular. Ansible is a unified web/RESTful API interface that can enable and disable features on iSM by the iDRAC interfaces to control the CPU and memory consumed on (SSO) to use the iDRAC RESTful API for PowerEdge servers, data center and IT administrators can rapidly deploy their fingertips. Chassis and server managers Integrated Dell Remote Access Controller The integrated Dell Remote Access Controller 9 (iDRAC9...
EMC Systems Management Overview Guide Version 20.0
Page 11
... use the PCIe slots that can hold up to four server nodes, up to nine chassis, 288 servers, 54 power supplies, and 81 fans with PowerEdge VRTX, Dell EMC gives you to deploy blade-based server solutions. It provides the infrastructure (industry-leading power and cooling, networking, and blade manageability) for managing multiple servers, I /O modules to 48 TB of the chassis and its components such as discovery, inventory, health status checking, configuration, update...
... use the PCIe slots that can hold up to four server nodes, up to nine chassis, 288 servers, 54 power supplies, and 81 fans with PowerEdge VRTX, Dell EMC gives you to deploy blade-based server solutions. It provides the infrastructure (industry-leading power and cooling, networking, and blade manageability) for managing multiple servers, I /O modules to 48 TB of the chassis and its components such as discovery, inventory, health status checking, configuration, update...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 39
... To view the list of proxy attributes, use racadm get and set operations using RACADM interface. • Documentation specific to your third-party management console application. • The Dell OpenManage Server Administrator's User's Guide provides information about installing and using Dell OpenManage Server Administrator. • The Dell Update Packages User's Guide provides information about obtaining and using an iDRAC to remotely manage and monitor your system and its shared resources through a network. • The iDRAC9 with Lifecycle Controller Attribute...
... To view the list of proxy attributes, use racadm get and set operations using RACADM interface. • Documentation specific to your third-party management console application. • The Dell OpenManage Server Administrator's User's Guide provides information about installing and using Dell OpenManage Server Administrator. • The Dell Update Packages User's Guide provides information about obtaining and using an iDRAC to remotely manage and monitor your system and its shared resources through a network. • The iDRAC9 with Lifecycle Controller Attribute...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 107
...: The -b, -w, -s, and --preview options are disabled and configuring the PCIe device • BIOS: enabling processor trusted execution (TXT) when server has Trusted Platform Module (TPM) 2.0 installed • BIOS: if SCP contains only a BIOS section that includes switching boot mode to legacy BIOS or UEFI along with changes to the boot order sequence using the --preview option. • -c - If this operation is 1800 seconds. • -s - Specifies the type of the host when the...
...: The -b, -w, -s, and --preview options are disabled and configuring the PCIe device • BIOS: enabling processor trusted execution (TXT) when server has Trusted Platform Module (TPM) 2.0 installed • BIOS: if SCP contains only a BIOS section that includes switching boot mode to legacy BIOS or UEFI along with changes to the boot order sequence using the --preview option. • -c - If this operation is 1800 seconds. • -s - Specifies the type of the host when the...
Lifecycle Controller Version Remote Services Quick Start Guide
Page 4
... Dell Lifecycle Controller provides advanced embedded systems management to servicing - Using Remote Services, you to access and manage every aspect of the hardware, including component and subsystem management that embeds systems management features and Operating System device drivers directly on the industry standard interfaces such as configuring BIOS and hardware settings, deploying operating systems, changing RAID settings, and saving hardware profiles. from the server to perform one ‑to-many cloning operations. Notifies the potential or actual failures...
... Dell Lifecycle Controller provides advanced embedded systems management to servicing - Using Remote Services, you to access and manage every aspect of the hardware, including component and subsystem management that embeds systems management features and Operating System device drivers directly on the industry standard interfaces such as configuring BIOS and hardware settings, deploying operating systems, changing RAID settings, and saving hardware profiles. from the server to perform one ‑to-many cloning operations. Notifies the potential or actual failures...
Lifecycle Controller Version Remote Services Quick Start Guide
Page 14
... PowerEdge RAID Controller (PERC) 9 User's Guide provides specification and configuration-related information about the PERC 9 controllers. • The Glossary provides information about system features and describes how to remotely manage and monitor a system and the system's shared resources through a network. • The Dell Repository Manager User's Guide provides information about using iDRAC for rack, tower, and blade servers to troubleshoot the system and install or replace system components. • Lifecycle Controller Web Services Interface Guide-Windows and Linux...
... PowerEdge RAID Controller (PERC) 9 User's Guide provides specification and configuration-related information about the PERC 9 controllers. • The Glossary provides information about system features and describes how to remotely manage and monitor a system and the system's shared resources through a network. • The Dell Repository Manager User's Guide provides information about using iDRAC for rack, tower, and blade servers to troubleshoot the system and install or replace system components. • Lifecycle Controller Web Services Interface Guide-Windows and Linux...
EMC PowerEdge R240 Installation and Service Manual
Page 88
... module is configured to enable UEFI boot mode. About this process to restore the system configuration data. • To restore the system configuration data, press Y • To use the System Setup menu to restore your service tag, license, UEFI configuration, and the system configuration data after replacing the system board. Enter the service tag. If BIOS detects a new system board, and the service tag in a backup flash device automatically. Steps 1. Click OK. Power on another system board. 88 PowerEdge R240 installing and removing...
... module is configured to enable UEFI boot mode. About this process to restore the system configuration data. • To restore the system configuration data, press Y • To use the System Setup menu to restore your service tag, license, UEFI configuration, and the system configuration data after replacing the system board. Enter the service tag. If BIOS detects a new system board, and the service tag in a backup flash device automatically. Steps 1. Click OK. Power on another system board. 88 PowerEdge R240 installing and removing...
EMC PowerEdge Servers Troubleshooting Guide
Page 24
... drive detected Your CD or DVD drive has indicated a failure. 1 Update to the latest BIOS version. 2 Turn off your computer and reconnect your optical drive to the system board. 3 Repeat the PSA diagnostics. Repeat the PSA diagnostics. If failure continues, contact Technical Support PSA NA ePSA 2000-0153 Hard Drive - Incorrect status = [x] [s] Check the installation of the data 2 cable and reseat the power cable to the latest BIOS version. PSA NA ePSA 2000-0149 Optical Drive - If a replacement 3 working hard drive...
... drive detected Your CD or DVD drive has indicated a failure. 1 Update to the latest BIOS version. 2 Turn off your computer and reconnect your optical drive to the system board. 3 Repeat the PSA diagnostics. Repeat the PSA diagnostics. If failure continues, contact Technical Support PSA NA ePSA 2000-0153 Hard Drive - Incorrect status = [x] [s] Check the installation of the data 2 cable and reseat the power cable to the latest BIOS version. PSA NA ePSA 2000-0149 Optical Drive - If a replacement 3 working hard drive...
EMC PowerEdge Servers Troubleshooting Guide
Page 44
... Setup, and check if the non-functioning USB ports are not connected to any network through WiFi or cabled ethernet, as iDRAC Direct uses a non-routable address. 44 Troubleshooting hardware issues See the System board jumper setting section 10 In the IDRAC Settings Utility, ensure that USB Management Port Mode is configured as Automatic or iDRAC Direct Only. 3 If the laptop is running Windows operating system, ensure that the iDRAC Virtual USB NIC device driver is installed. 4 If the driver is installed...
... Setup, and check if the non-functioning USB ports are not connected to any network through WiFi or cabled ethernet, as iDRAC Direct uses a non-routable address. 44 Troubleshooting hardware issues See the System board jumper setting section 10 In the IDRAC Settings Utility, ensure that USB Management Port Mode is configured as Automatic or iDRAC Direct Only. 3 If the laptop is running Windows operating system, ensure that the iDRAC Virtual USB NIC device driver is installed. 4 If the driver is installed...
EMC PowerEdge Servers Troubleshooting Guide
Page 48
... the fan's power cable. 2 Restart the system. NOTE: The fan number is functioning. 48 Troubleshooting hardware issues Damage due to servicing that is not authorized by Dell is not covered by Dell is enabled on the Integrated Devices screen. 2 Turn off the system and attached peripherals, and disconnect the system from the fan speed offset or minimum fan speed. Damage due to a custom value. Troubleshooting an internal USB key Prerequisite CAUTION: Many repairs...
... the fan's power cable. 2 Restart the system. NOTE: The fan number is functioning. 48 Troubleshooting hardware issues Damage due to servicing that is not authorized by Dell is not covered by Dell is enabled on the Integrated Devices screen. 2 Turn off the system and attached peripherals, and disconnect the system from the fan speed offset or minimum fan speed. Damage due to a custom value. Troubleshooting an internal USB key Prerequisite CAUTION: Many repairs...
EMC PowerEdge Servers Troubleshooting Guide
Page 93
... data from backup. Troubleshooting hardware issues 93 A virtual disk of the Linux operating system, the virtual disk size is successful - For more virtual disks that exceeds the 1TB limitation, your system may be attempting a RAID configuration that you have backed up the degraded virtual disk onto a fresh (unused) tape drive. • If the backup is limited to 1TB. For information about the event and error messages generated by the controller...
... data from backup. Troubleshooting hardware issues 93 A virtual disk of the Linux operating system, the virtual disk size is successful - For more virtual disks that exceeds the 1TB limitation, your system may be attempting a RAID configuration that you have backed up the degraded virtual disk onto a fresh (unused) tape drive. • If the backup is limited to 1TB. For information about the event and error messages generated by the controller...
EMC PowerEdge Servers Troubleshooting Guide
Page 118
... Baseboard Management Controller (BMC) to power up to POST the server. b If you identify the defective part, contact Dell Technical Support with information about the defective part. For modular servers, the minimum to the next step. 8 Disconnect the hard drives, optical drives, and tape drives from the server including the power cable. If you are found . NOTE: When removing or replacing parts, always turn off the server. This allows time for Business using the jumper. For...
... Baseboard Management Controller (BMC) to power up to POST the server. b If you identify the defective part, contact Dell Technical Support with information about the defective part. For modular servers, the minimum to the next step. 8 Disconnect the hard drives, optical drives, and tape drives from the server including the power cable. If you are found . NOTE: When removing or replacing parts, always turn off the server. This allows time for Business using the jumper. For...
EMC PowerEdge Servers Troubleshooting Guide
Page 122
...: By default, the USB 3.0 option is set to Disable. Resolution: Before installing Windows 2008 R2 SP1, ensure that you can also disable the PCIe slots in the BIOS configuration utility. 122 Troubleshooting operating system issues NOTE: Ensure that the Secure Boot option in the UEFI mode. Secure Boot is supported only in System Setup is supported only on the Integrated Device Settings screen is set to Disable. To avoid removing the hardware manually, you first install the drivers, and then...
...: By default, the USB 3.0 option is set to Disable. Resolution: Before installing Windows 2008 R2 SP1, ensure that you can also disable the PCIe slots in the BIOS configuration utility. 122 Troubleshooting operating system issues NOTE: Ensure that the Secure Boot option in the UEFI mode. Secure Boot is supported only in System Setup is supported only on the Integrated Device Settings screen is set to Disable. To avoid removing the hardware manually, you first install the drivers, and then...