Command Line Interface (CLI) Guide (.htm)
Page 249
... be : On, Off, Test-Fail, Testing, Searching or Fault. DELL CONFIDENTIAL - PRELIMINARY 9/13/06 - Status Classification Overload Counter Short Counter Denied Counter Absent Counter Invalid Signature Counter Describes the inline power operational status of the powered device. Can be : 0.44 - 12.95, 0.44 - 3.84... 6.49 or 6.49 - 12.95. Counts the number of times power has been removed because powered device dropout was detected. Counts the number of overload conditions that has been detected. The power consumption range of the port. Counts the number of short conditions that has ...
... be : On, Off, Test-Fail, Testing, Searching or Fault. DELL CONFIDENTIAL - PRELIMINARY 9/13/06 - Status Classification Overload Counter Short Counter Denied Counter Absent Counter Invalid Signature Counter Describes the inline power operational status of the powered device. Can be : 0.44 - 12.95, 0.44 - 3.84... 6.49 or 6.49 - 12.95. Counts the number of times power has been removed because powered device dropout was detected. Counts the number of overload conditions that has been detected. The power consumption range of the port. Counts the number of short conditions that has ...
User's Guide (.htm)
Page 103
... memory could not be enabled and cannot be used if the power supply is low. Low - Power Consumption - The possible field values are : Auto - Indicates that the PowerConnect device is assigned a power consumption level of .44 to the device using the PoE module. Port Settings Select a Port - Never - PoE Operational Status - Indicates if the port is...
... memory could not be enabled and cannot be used if the power supply is low. Low - Power Consumption - The possible field values are : Auto - Indicates that the PowerConnect device is assigned a power consumption level of .44 to the device using the PoE module. Port Settings Select a Port - Never - PoE Operational Status - Indicates if the port is...
User's Guide (.htm)
Page 104
... the equivalent CLI commands for viewing fields displayed on an interface. Configures the priority of the interface from the point of view of the powered device type. Indicates that the port is assigned a power consumption level of 3.84 to the PSE. www.dell.com | support.dell.com 3.84 - 6.49 - Indicates that the port is updated.
... the equivalent CLI commands for viewing fields displayed on an interface. Configures the priority of the interface from the point of view of the powered device type. Indicates that the port is assigned a power consumption level of 3.84 to the PSE. www.dell.com | support.dell.com 3.84 - 6.49 - Indicates that the port is updated.