User Guide
Page 7
... Linksys WebView Managed switch allows you to control network access and traffic flow. Individual users or applications can provide maximum output power per PoE port up to meet their QoS needs. Extensive QoS features makes the solution ideal for fixed 10/100 Base-T/TX ports. There are features that model. Link aggregation allows multiple high-bandwidth trunks between switches to expand and grow your network. User control is secured using MAC-based filtering. IGMP Snooping limits bandwidth...
... Linksys WebView Managed switch allows you to control network access and traffic flow. Individual users or applications can provide maximum output power per PoE port up to meet their QoS needs. Extensive QoS features makes the solution ideal for fixed 10/100 Base-T/TX ports. There are features that model. Link aggregation allows multiple high-bandwidth trunks between switches to expand and grow your network. User control is secured using MAC-based filtering. IGMP Snooping limits bandwidth...
User Guide
Page 8
... speed and duplex accordingly. Gigabit (Orange) The Gigabit LED lights up to automatically detect the speed of the Switch. The Fast Ethernet ports support network speeds of the device connected to automatically detect the speed of 10Mbps, 100Mbps, or 1000Mbps. Front Panel The LEDs and ports are located on . Auto-sensing technology enables each port to indicate a functional network link through the corresponding port (1 through 8) with an RJ-45 connector. Refer to Chapter 4: Using the Console Interface for Configuration...
... speed and duplex accordingly. Gigabit (Orange) The Gigabit LED lights up to automatically detect the speed of the Switch. The Fast Ethernet ports support network speeds of the device connected to automatically detect the speed of 10Mbps, 100Mbps, or 1000Mbps. Front Panel The LEDs and ports are located on . Auto-sensing technology enables each port to indicate a functional network link through the corresponding port (1 through 8) with an RJ-45 connector. Refer to Chapter 4: Using the Console Interface for Configuration...
User Guide
Page 14
... admin in the next chapter. Click the Start button. 2. Select a port to the Switch through the web utility, which is SRW2008. The Login screen will now appear. Leave the Password field blank. 8 Select Programs > Accessories > Communications > HyperTerminal. Set the serial port settings as follows, then click OK. The Switch can also be configured using CLI through the console interface or through a telnet connection. Chapter 4 Configuration Using the Console Interface Chapter 4: Configuration Using the Console Interface Overview The Switch...
... admin in the next chapter. Click the Start button. 2. Select a port to the Switch through the web utility, which is SRW2008. The Login screen will now appear. Leave the Password field blank. 8 Select Programs > Accessories > Communications > HyperTerminal. Set the serial port settings as follows, then click OK. The Switch can also be configured using CLI through the console interface or through a telnet connection. Chapter 4 Configuration Using the Console Interface Chapter 4: Configuration Using the Console Interface Overview The Switch...
User Guide
Page 21
... the port numbers, their status, Link status, speed and duplex mode, and status of packet transmissions. After the Switch has rebooted, the Switch Main Menu screen will be sure that only valid entries have been configured. Download the new boot code. You will be rebooted. Chapter 4 Configuration Using the Console Interface File Management The File Management screen allows you want to restart the Switch. Reboot System Select Reboot System and press the Enter key if you to the factory default settings, select Restore System Default Settings...
... the port numbers, their status, Link status, speed and duplex mode, and status of packet transmissions. After the Switch has rebooted, the Switch Main Menu screen will be sure that only valid entries have been configured. Download the new boot code. You will be rebooted. Chapter 4 Configuration Using the Console Interface File Management The File Management screen allows you want to restart the Switch. Reboot System Select Reboot System and press the Enter key if you to the factory default settings, select Restore System Default Settings...
User Guide
Page 23
... NOTE: The LEDs displayed in the User Name field, and leave the Password field blank. Default Gateway The Default Gateway is recommended. Open your web browser and enter 192.168.1.254 into the Address field. The first time you click a port's LED, the statistics for specific switches are displayed here (configurable from Setup > Network Settings tab). You can set a password later from the web-based utility: Setup, Port Management, VLAN Management, Statistics, ACL, Security, QoS (Quality of Fast Ethernet switches. Setup > Summary...
... NOTE: The LEDs displayed in the User Name field, and leave the Password field blank. Default Gateway The Default Gateway is recommended. Open your web browser and enter 192.168.1.254 into the Address field. The first time you click a port's LED, the statistics for specific switches are displayed here (configurable from Setup > Network Settings tab). You can set a password later from the web-based utility: Setup, Port Management, VLAN Management, Statistics, ACL, Security, QoS (Quality of Fast Ethernet switches. Setup > Summary...
User Guide
Page 24
... Gigabit Switch with a Static or Dynamic IP address (configurable from Setup > Network Settings tab). System Object ID The system object identifier is located, such as 3rd floor. IP Configuration Management VLAN This drop-down allows you to assign DHCP or static IP settings to interfaces and assign default gateways. Default Gateway Enter the IP address of time that has elapsed since the Switch was last reset. System Information Serial Number The serial number of the Switch. Hardware version The current hardware version...
... Gigabit Switch with a Static or Dynamic IP address (configurable from Setup > Network Settings tab). System Object ID The system object identifier is located, such as 3rd floor. IP Configuration Management VLAN This drop-down allows you to assign DHCP or static IP settings to interfaces and assign default gateways. Default Gateway Enter the IP address of time that has elapsed since the Switch was last reset. System Information Serial Number The serial number of the Switch. Hardware version The current hardware version...
User Guide
Page 27
... negotiation process. Admin Status The admin status of the selected LAG. It is displayed here. Current Advertisement The port advertises its capabilities to its capabilities to the port to save your changes. 8-Port 10/100/1000 Gigabit Switch with Webview Port Management > Link Aggregation Port Management > Link Aggregation LAG This indicates if the port is advertising a 1000Mbps full duplex mode setting. Chapter 5 Advanced Configuration •• Max Capability Indicates that the port speeds and duplex mode settings can be listed here for...
... negotiation process. Admin Status The admin status of the selected LAG. It is displayed here. Current Advertisement The port advertises its capabilities to its capabilities to the port to save your changes. 8-Port 10/100/1000 Gigabit Switch with Webview Port Management > Link Aggregation Port Management > Link Aggregation LAG This indicates if the port is advertising a 1000Mbps full duplex mode setting. Chapter 5 Advanced Configuration •• Max Capability Indicates that the port speeds and duplex mode settings can be listed here for...
User Guide
Page 29
... Add button. VLAN Name Displays the user-defined VLAN name. To add the defined range of VLAN ID numbers, press the Add Range button. 8-Port 10/100/1000 Gigabit Switch with VLANs. Power Consumption (milliwatts) Indicates the amount of the VLAN being configured. VLAN Management > Create VLAN Single VLAN VLAN ID (2-4094) Indicates the ID number of the power used to 256 VLANs can supply. The VLAN ID, VLAN Name, and status of power the device can be designated. Up to add VLANs one at a time...
... Add button. VLAN Name Displays the user-defined VLAN name. To add the defined range of VLAN ID numbers, press the Add Range button. 8-Port 10/100/1000 Gigabit Switch with VLANs. Power Consumption (milliwatts) Indicates the amount of the VLAN being configured. VLAN Management > Create VLAN Single VLAN VLAN ID (2-4094) Indicates the ID number of the power used to 256 VLANs can supply. The VLAN ID, VLAN Name, and status of power the device can be designated. Up to add VLANs one at a time...
User Guide
Page 37
... the source port IP address to which increases network security. Match IP Precedence Matches the packet IP Precedence value to start a session. The Add to List button adds the configured IP Based ACLs to the IP Based ACL Table at the bottom of the IP address are ignored, while the last eight bits are used and which is important. Protocol Creates an ACE (Access Control Event) based...
... the source port IP address to which increases network security. Match IP Precedence Matches the packet IP Precedence value to start a session. The Add to List button adds the configured IP Based ACLs to the IP Based ACL Table at the bottom of the IP address are ignored, while the last eight bits are used and which is important. Protocol Creates an ACE (Access Control Event) based...
User Guide
Page 41
... host status. In addition, the Limited Dynamic Lock mode is 10 seconds. Security > HTTPS Settings Port Displays the port number for specific ports and VLANs. The default is 1. In order to change the Learning Mode, the Lock Interface must be applied to packets arriving in order to either it was learned on a locked port. 8-Port 10/100/1000 Gigabit Switch with a trap •• Cause the port to configure advanced port...
... host status. In addition, the Limited Dynamic Lock mode is 10 seconds. Security > HTTPS Settings Port Displays the port number for specific ports and VLANs. The default is 1. In order to change the Learning Mode, the Lock Interface must be applied to packets arriving in order to either it was learned on a locked port. 8-Port 10/100/1000 Gigabit Switch with a trap •• Cause the port to configure advanced port...
User Guide
Page 49
... as part of hops that identifies the revision of the chosen network 8-Port 10/100/1000 Gigabit Switch with Webview layer protocols has been configured, packets from the administrative state. •• Disabled Disables point-to configure and test the data link. The possible field values are: •• Auto Point-to -point link. After a link is the specified instance root. 43 Point-to-Point Oper Status...
... as part of hops that identifies the revision of the chosen network 8-Port 10/100/1000 Gigabit Switch with Webview layer protocols has been configured, packets from the administrative state. •• Disabled Disables point-to configure and test the data link. The possible field values are: •• Auto Point-to -point link. After a link is the specified instance root. 43 Point-to-Point Oper Status...
User Guide
Page 52
... of time the host waits, after requesting to the appropriate port or VLAN. VLAN ID Identifies a VLAN to be created. The Port and LAG tables also reflect the manner in the Ports and LAGs tables. The configuration options are not included the Multicast group, even if IGMP snooping designated the port to a specific Multicast service address group. The Bridge Multicast screen also assigns ports to join a Multicast group. •• Static Indicates the port is user-defined...
... of time the host waits, after requesting to the appropriate port or VLAN. VLAN ID Identifies a VLAN to be created. The Port and LAG tables also reflect the manner in the Ports and LAGs tables. The configuration options are not included the Multicast group, even if IGMP snooping designated the port to a specific Multicast service address group. The Bridge Multicast screen also assigns ports to join a Multicast group. •• Static Indicates the port is user-defined...
User Guide
Page 59
... Network administrators configure port mirroring by selecting a specific port to copy all error reporting. No Cable means there is no cable connected to which the packets are : •• RxOnly Defines the port mirroring on both receiving and transmitting ports. Logging Indicates if device global logs for port mirroring. Port mirroring also enables switch performance monitoring. Test Result This is 120 meters. Cables are tested when the ports are sent per each event logging. Admin > Port Mirroring Port mirroring monitors and mirrors network traffic by default...
... Network administrators configure port mirroring by selecting a specific port to copy all error reporting. No Cable means there is no cable connected to which the packets are : •• RxOnly Defines the port mirroring on both receiving and transmitting ports. Logging Indicates if device global logs for port mirroring. Port mirroring also enables switch performance monitoring. Test Result This is 120 meters. Cables are tested when the ports are sent per each event logging. Admin > Port Mirroring Port mirroring monitors and mirrors network traffic by default...
User Guide
Page 66
... number of users which network traffic is averaged over a minimum time increment. Class maps are configured to packets in Access Control Lists (ACL) that connect two networks. ACE Filters in a first-fit fashion. Back Pressure A mechanism used to look at a faster than normal rates. Bridges operate at faster than normal rate. CIR (Committed Information Rate) The data rate is forwarded. WEB: For additional terms, please visit the glossary at www.linksys.com...
... number of users which network traffic is averaged over a minimum time increment. Class maps are configured to packets in Access Control Lists (ACL) that connect two networks. ACE Filters in a first-fit fashion. Back Pressure A mechanism used to look at a faster than normal rates. Bridges operate at faster than normal rate. CIR (Committed Information Rate) The data rate is forwarded. WEB: For additional terms, please visit the glossary at www.linksys.com...
User Guide
Page 67
... with the source host. LAG (Link Aggregated Group) Aggregates ports or VLANs into a VLANs. Domain A specific name for tagging packets with priority information. Flow Control Enables lower speed devices to obtain configuration parameters, such as a network address. FTP (File Transfer Protocol) A protocol used to connect to implement secure exchange of websites into a multicast domain. GBIC (GigaBit Interface Converter) A hardware module used to servers on a network. By default this protocol uses TCP port 443. ISP (Internet Service Provider) A company that make...
... with the source host. LAG (Link Aggregated Group) Aggregates ports or VLANs into a VLANs. Domain A specific name for tagging packets with priority information. Flow Control Enables lower speed devices to obtain configuration parameters, such as a network address. FTP (File Transfer Protocol) A protocol used to connect to implement secure exchange of websites into a multicast domain. GBIC (GigaBit Interface Converter) A hardware module used to servers on a network. By default this protocol uses TCP port 443. ISP (Internet Service Provider) A company that make...
User Guide
Page 68
...+ (Terminal Access Controller Access Control System Plus) Proprietary Cisco enhancement to files, printing, communications, and other services. MD5 is connected to a computer or device that connects multiple networks together. Port Mirroring Monitors and mirrors network traffic by SNMP to identify it. Switches support any arrangement of data sharing, storage, and/or transmission between users. Provides additional support for the Internet used to multiple ports. MIB (Management Information Base) MIBs contain information describing specific aspects of a single packet...
...+ (Terminal Access Controller Access Control System Plus) Proprietary Cisco enhancement to files, printing, communications, and other services. MD5 is connected to a computer or device that connects multiple networks together. Port Mirroring Monitors and mirrors network traffic by SNMP to identify it. Switches support any arrangement of data sharing, storage, and/or transmission between users. Provides additional support for the Internet used to multiple ports. MIB (Management Information Base) MIBs contain information describing specific aspects of a single packet...
User Guide
Page 70
...SSH Secure Support) Security Features IEEE 802.1X 802.1X - Appendix D Specifications Appendix D: Specifications Specifications Model Ports Cabling Type LEDs Performance Switching Capacity Forwarding Rate Layer 2 MAC table size Number of VLANs VLAN HOL Blocking Management Web User Interface SNMP SNMP MIBs SRW2008 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI/MDI-X Autonegotiate/Manual Setting UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or better for 1000BASE-TX Link/Act, Gigabit...
...SSH Secure Support) Security Features IEEE 802.1X 802.1X - Appendix D Specifications Appendix D: Specifications Specifications Model Ports Cabling Type LEDs Performance Switching Capacity Forwarding Rate Layer 2 MAC table size Number of VLANs VLAN HOL Blocking Management Web User Interface SNMP SNMP MIBs SRW2008 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI/MDI-X Autonegotiate/Manual Setting UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or better for 1000BASE-TX Link/Act, Gigabit...
User Guide
Page 72
... (SSH) RADIUS Port Mirroring TFTP Upgrade SSL security for 1000BASE-T Link/Act, PoE, System 802.3af compliant. Appendix D Specifications Model Ports Cabling Type LEDs POE SRW2008MP 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI/MDI-X Autonegotiate/Manual Setting UTP CAT 5 or Better for 10BASE-T/100BASE-TX UTP CAT 5e or Better for Web UI DHCP Client BootP SNTP Xmodem Upgrade Cable Diagnostics PING Telnet Client (SSH Secure Support...
... (SSH) RADIUS Port Mirroring TFTP Upgrade SSL security for 1000BASE-T Link/Act, PoE, System 802.3af compliant. Appendix D Specifications Model Ports Cabling Type LEDs POE SRW2008MP 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI/MDI-X Autonegotiate/Manual Setting UTP CAT 5 or Better for 10BASE-T/100BASE-TX UTP CAT 5e or Better for Web UI DHCP Client BootP SNTP Xmodem Upgrade Cable Diagnostics PING Telnet Client (SSH Secure Support...
User Guide
Page 73
... Webview Model Ports Cabling Type LEDs POE Performance Switching Capacity Forwarding Rate Layer 2 MAC table size Number of VLANs VLAN HOL Blocking Management Web User Interface SNMP SNMP MIBs RMON SRW2008P 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with Support for 1000BASE-T Link/Act, PoE, System 802.3af complaint. Appendix D Specifications QoS Priority levels Scheduling Class of Line Blocking Prevention Built-In Web UI for Easy Browser-Based Configuration (HTTP/HTTPS) SNMP Version 1, 2c, 3 with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI...
... Webview Model Ports Cabling Type LEDs POE Performance Switching Capacity Forwarding Rate Layer 2 MAC table size Number of VLANs VLAN HOL Blocking Management Web User Interface SNMP SNMP MIBs RMON SRW2008P 8 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000Base-T with Support for 1000BASE-T Link/Act, PoE, System 802.3af complaint. Appendix D Specifications QoS Priority levels Scheduling Class of Line Blocking Prevention Built-In Web UI for Easy Browser-Based Configuration (HTTP/HTTPS) SNMP Version 1, 2c, 3 with 2 shared SFP ports on port 7 and 8 (combo port) Console Port Auto MDI...
User Guide
Page 74
... Encryption Access Control ACLs Drop or Rate Limit Based on a Port can be Mirrored to 8 Groups Storm Control Broadcast, Multicast and Unknown Unicast Spanning Tree IEEE 802.1d Spanning Tree, IEEE 802.1w Rapid Spanning Tree, IEEE 802.1s Multiple Spanning Tree IGMP Snooping IGMP (v1/v2) snooping limits 8-Port 10/100/1000 Gigabit Switch with a Network Analyzer or RMON Probe Other Management Traceroute Secure Socket Layer (SSL) Secure Shell (SSH) RADIUS Port Mirroring TFTP Upgrade SSL security for Web UI DHCP Client BootP SNTP Xmodem Upgrade Cable...
... Encryption Access Control ACLs Drop or Rate Limit Based on a Port can be Mirrored to 8 Groups Storm Control Broadcast, Multicast and Unknown Unicast Spanning Tree IEEE 802.1d Spanning Tree, IEEE 802.1w Rapid Spanning Tree, IEEE 802.1s Multiple Spanning Tree IGMP Snooping IGMP (v1/v2) snooping limits 8-Port 10/100/1000 Gigabit Switch with a Network Analyzer or RMON Probe Other Management Traceroute Secure Socket Layer (SSL) Secure Shell (SSH) RADIUS Port Mirroring TFTP Upgrade SSL security for Web UI DHCP Client BootP SNTP Xmodem Upgrade Cable...