Hardware Installation Guide
Page 7
...18 Attaching the Optional Cable Guide 2-19 Installing the Switch on a Wall 2-20 Attaching the Brackets to the Switch 2-21 Mounting the Switch to a Wall 2-22 Powering On the Switch and Running POST 2-24 Connecting to DC Power 2-25 Preparing for Installation 2-25 Grounding the Switch 2-26 Wiring the DC-Input Power Source 2-29 ...Correcting Module POST Failures 3-2 Diagnosing Problems 3-3 Technical Specifications A-1 Connectors and Cable Specifications B-1 Connector Specifications B-1 10/100 Ports B-1 100BASE-FX Ports B-2 Contents 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide vii
...18 Attaching the Optional Cable Guide 2-19 Installing the Switch on a Wall 2-20 Attaching the Brackets to the Switch 2-21 Mounting the Switch to a Wall 2-22 Powering On the Switch and Running POST 2-24 Connecting to DC Power 2-25 Preparing for Installation 2-25 Grounding the Switch 2-26 Wiring the DC-Input Power Source 2-29 ...Correcting Module POST Failures 3-2 Diagnosing Problems 3-3 Technical Specifications A-1 Connectors and Cable Specifications B-1 Connector Specifications B-1 10/100 Ports B-1 100BASE-FX Ports B-2 Contents 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide vii
Hardware Installation Guide
Page 9
INDEX Class 1 Laser Product Warning C-22 Laser Beam Exposure Warning C-23 No On/Off Switch Warning C-24 Chassis Warning-Rack-Mounting and Servicing C-25 Reinforced Insulation Warning C-29 LAN Connections Only Warning C-30 No Field-Replaceable Units Warning C-31 Installation Warning C-32 ... Equipment Warning C-36 Ground Connection Warning C-37 Qualified Personnel Warning C-38 DC Power Disconnection Warning C-39 Exposed Wire Lead Warning C-41 Contents 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide ix
INDEX Class 1 Laser Product Warning C-22 Laser Beam Exposure Warning C-23 No On/Off Switch Warning C-24 Chassis Warning-Rack-Mounting and Servicing C-25 Reinforced Insulation Warning C-29 LAN Connections Only Warning C-30 No Field-Replaceable Units Warning C-31 Installation Warning C-32 ... Equipment Warning C-36 Ground Connection Warning C-37 Qualified Personnel Warning C-38 DC Power Disconnection Warning C-39 Exposed Wire Lead Warning C-41 Contents 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide ix
Hardware Installation Guide
Page 22
...transfer mode (ATM) modules • On the Catalyst 2924M XL DC switch, a direct current (DC) power converter • On the Catalyst 2912 LRE XL and 2924 LRE XL switches, up to 24 LRE ports through one RJ-21 connector and hot swapping capability with the Cisco LRE customer premises equipment (CPE) devices •...; Supports up to 2048 MAC addresses on the Catalyst 2924 XL, 2924C XL, and 2912 XL switches • Supports up to...
...transfer mode (ATM) modules • On the Catalyst 2924M XL DC switch, a direct current (DC) power converter • On the Catalyst 2912 LRE XL and 2924 LRE XL switches, up to 24 LRE ports through one RJ-21 connector and hot swapping capability with the Cisco LRE customer premises equipment (CPE) devices •...; Supports up to 2048 MAC addresses on the Catalyst 2924 XL, 2924C XL, and 2912 XL switches • Supports up to...
Hardware Installation Guide
Page 23
Chapter 1 Product Overview Figure 1-1 Catalyst 2900 Series XL Switches Version Number Description WS-C2912-LRE-XL 4 fixed autosensing 10/100 ports INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 12 LRE ports Cisco RPS 300 WS-C2924-LRE-XL 4 fixed autosensing 10/100 ports 24 LRE ports INPUT OUTPUT PWR PWR ...RESET TEMP FAN 9X 10X 11X 12X Cisco RPS 300 WS-C2912-XL 12 fixed autosensing 10/100 ports MODE 1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 10BaseT/100BASE-TX 11X 12X Catalyst 2900 SERIES XL WS-C2924C...
Chapter 1 Product Overview Figure 1-1 Catalyst 2900 Series XL Switches Version Number Description WS-C2912-LRE-XL 4 fixed autosensing 10/100 ports INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 12 LRE ports Cisco RPS 300 WS-C2924-LRE-XL 4 fixed autosensing 10/100 ports 24 LRE ports INPUT OUTPUT PWR PWR ...RESET TEMP FAN 9X 10X 11X 12X Cisco RPS 300 WS-C2912-XL 12 fixed autosensing 10/100 ports MODE 1X 2X 3X 4X 5X 6X 7X 8X 9X 10X 10BaseT/100BASE-TX 11X 12X Catalyst 2900 SERIES XL WS-C2924C...
Hardware Installation Guide
Page 27
...) and distances of up to 24 Cisco LRE customer premises equipment (CPE) devices though structured or unstructured wiring, such as follows: • If the switch port and the port on the attached device are connected through a private branch exchange (PBX) switch, a Cisco LRE 48 POTS Splitter can be...Ethernet (LRE) ports (Figure 1-4) use 50/125- The PBX routes voice traffic to the Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide. The link between the switch and the attached device can be connected to the patch panel through a basic telephone service,...
...) and distances of up to 24 Cisco LRE customer premises equipment (CPE) devices though structured or unstructured wiring, such as follows: • If the switch port and the port on the attached device are connected through a private branch exchange (PBX) switch, a Cisco LRE 48 POTS Splitter can be...Ethernet (LRE) ports (Figure 1-4) use 50/125- The PBX routes voice traffic to the Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide. The link between the switch and the attached device can be connected to the patch panel through a basic telephone service,...
Hardware Installation Guide
Page 32
System is receiving power and functioning properly. Table 1-2 lists the LED colors and their meanings. Front-Panel Description Figure 1-7 Catalyst 2912 LRE XL and 2924 LRE XL LEDs 10/100 port LEDs Chapter 1 Product Overview SYSTEM RPS MODE LRE STAT DUPLX SPEED Mode ...Off Green Amber System Status System is not functioning properly. For information on the System LED colors during POST, see the "Powering On the Switch and Running POST" section on page 2-24. 1-12 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04 System is receiving power but is not powered up.
System is receiving power and functioning properly. Table 1-2 lists the LED colors and their meanings. Front-Panel Description Figure 1-7 Catalyst 2912 LRE XL and 2924 LRE XL LEDs 10/100 port LEDs Chapter 1 Product Overview SYSTEM RPS MODE LRE STAT DUPLX SPEED Mode ...Off Green Amber System Status System is not functioning properly. For information on the System LED colors during POST, see the "Powering On the Switch and Running POST" section on page 2-24. 1-12 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04 System is receiving power but is not powered up.
Hardware Installation Guide
Page 38
...of Port Status LEDs for Different Modes on Catalyst 2900 LRE XL switches with Cisco IOS Release 12.0(5.x)WC1 or Cisco IOS Release 12.0(5.x)WC2 provide information about any connected LRE CPE devices. The LEDs on Catalyst 2900 LRE XL switches with this release or higher, use the ...12.4%+ 12.5 -24%+ 25 - 49%+ 50%+ Catalyst 2900 SERIES XL 1-18 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04 The LEDs on Catalyst 2912 LRE XL and 2924 LRE XL Switches (continued) Port Mode SPEED Port LED Color Cisco IOS Release 12.0(5.x)WC1/ WC21 Description Cisco IOS Release 12.0(5.x)...
...of Port Status LEDs for Different Modes on Catalyst 2900 LRE XL switches with Cisco IOS Release 12.0(5.x)WC1 or Cisco IOS Release 12.0(5.x)WC2 provide information about any connected LRE CPE devices. The LEDs on Catalyst 2900 LRE XL switches with this release or higher, use the ...12.4%+ 12.5 -24%+ 25 - 49%+ 50%+ Catalyst 2900 SERIES XL 1-18 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04 The LEDs on Catalyst 2912 LRE XL and 2924 LRE XL Switches (continued) Port Mode SPEED Port LED Color Cisco IOS Release 12.0(5.x)WC1/ WC21 Description Cisco IOS Release 12.0(5.x)...
Hardware Installation Guide
Page 50
...than 6561 feet (2 kilometers) for Installation Chapter 2 Installation Hungary This equipment is operational by powering it on /off switch. Follow the procedures in a rack, or on page 2-24. Figyelmeztetés a felhasználói kézikönyv számára: Ez a berendezés ...233;si távolságok alkalmazását. Installation Guidelines The switch can be installed on a table or shelf, in the "Powering On the Switch and Running POST" section on a wall. Catalyst 2900 Series XL Hardware Installation Guide 2-6 78-6461-04 Removing screws, cover...
...than 6561 feet (2 kilometers) for Installation Chapter 2 Installation Hungary This equipment is operational by powering it on /off switch. Follow the procedures in a rack, or on page 2-24. Figyelmeztetés a felhasználói kézikönyv számára: Ez a berendezés ...233;si távolságok alkalmazását. Installation Guidelines The switch can be installed on a table or shelf, in the "Powering On the Switch and Running POST" section on a wall. Catalyst 2900 Series XL Hardware Installation Guide 2-6 78-6461-04 Removing screws, cover...
Hardware Installation Guide
Page 52
...Note The cable guide does not attach to the Catalyst 2912 LRE XL and 2924 LRE XL switches. • One RJ-45-to-DB-9 adapter • Cisco Information Packet, containing warranty, safety, and support information Note In addition to the switch (19-inch rack mount) - Four number-8... a rack - Four number-12 Phillips machine screws for attaching the brackets to the switch (24-inch rack mount) - Preparing for Installation Chapter 2 Installation • Mounting kit containing these items, the Catalyst 2924M XL DC switch also ships with a DC terminal block plug on a table, shelf, or desk ...
...Note The cable guide does not attach to the Catalyst 2912 LRE XL and 2924 LRE XL switches. • One RJ-45-to-DB-9 adapter • Cisco Information Packet, containing warranty, safety, and support information Note In addition to the switch (19-inch rack mount) - Four number-8... a rack - Four number-12 Phillips machine screws for attaching the brackets to the switch (24-inch rack mount) - Preparing for Installation Chapter 2 Installation • Mounting kit containing these items, the Catalyst 2924M XL DC switch also ships with a DC terminal block plug on a table, shelf, or desk ...
Hardware Installation Guide
Page 53
...the rack. • When mounting this unit in the mounting-kit envelope. Note Figure 2-1 shows brackets for one-rack-unit switches. 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-9 The supplied rack-mounting brackets can be mounted at the bottom of the unit. After ...the switch is mounted on page 2-24. The following guidelines are similar on the table or shelf near an AC power source. Rack-...
...the rack. • When mounting this unit in the mounting-kit envelope. Note Figure 2-1 shows brackets for one-rack-unit switches. 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-9 The supplied rack-mounting brackets can be mounted at the bottom of the unit. After ...the switch is mounted on page 2-24. The following guidelines are similar on the table or shelf near an AC power source. Rack-...
Hardware Installation Guide
Page 54
... point Figure 2-2 Mounting Brackets Points for Catalyst 2912 LRE XL and 2924 LRE XL Switches 19" rack mount point 24" rack 23" rack mount point mount point 54725 19" rack mount point 24" rack 23" rack mount point mount point To install the switch in these procedures: • "Removing ...Screws from the Switch" section on page 2-11 • "Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, 2924M...
... point Figure 2-2 Mounting Brackets Points for Catalyst 2912 LRE XL and 2924 LRE XL Switches 19" rack mount point 24" rack 23" rack mount point mount point 54725 19" rack mount point 24" rack 23" rack mount point mount point To install the switch in these procedures: • "Removing ...Screws from the Switch" section on page 2-11 • "Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, 2924M...
Hardware Installation Guide
Page 55
...2924C XL, 2924 XL, 2912MF XL, 2924M XL, or 2924M XL DC Switch Follow these steps to attach the brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, 2924M XL, or 2924M XL DC switch: The bracket orientation and screws that mounting brackets can be attached. Figure ...to remove the chassis screws in a fixed-port and a modular port switch. Chapter 2 Installation Installing the Switch in a Rack • "Attaching the Brackets to a Catalyst 2912 LRE XL or 2924 LRE XL Switch" section on page 2-16 • "Mounting the Switch in a Rack" section on page 2-18 • "Attaching the ...
...2924C XL, 2924 XL, 2912MF XL, 2924M XL, or 2924M XL DC Switch Follow these steps to attach the brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, 2924M XL, or 2924M XL DC switch: The bracket orientation and screws that mounting brackets can be attached. Figure ...to remove the chassis screws in a fixed-port and a modular port switch. Chapter 2 Installation Installing the Switch in a Rack • "Attaching the Brackets to a Catalyst 2912 LRE XL or 2924 LRE XL Switch" section on page 2-16 • "Mounting the Switch in a Rack" section on page 2-18 • "Attaching the ...
Hardware Installation Guide
Page 56
...XL, 2924C XL, and 2924 XL Fixed-Port Switches (Front-Panel Forward) Phillips flat-head screws Phillips truss-head screws 19" configuration MODE 1X 2X 3X 4X 5X 6X 7X 47738 23" and 24" configuration MODE 1X 2X 3X 4X 5X 6X 7X 2-12 Catalyst 2900 Series XL Hardware Installation Guide 78-6461...-04 Installing the Switch in a Rack Chapter 2 Installation • For a 19-inch or a telco rack, use the ...
...XL, 2924C XL, and 2924 XL Fixed-Port Switches (Front-Panel Forward) Phillips flat-head screws Phillips truss-head screws 19" configuration MODE 1X 2X 3X 4X 5X 6X 7X 47738 23" and 24" configuration MODE 1X 2X 3X 4X 5X 6X 7X 2-12 Catalyst 2900 Series XL Hardware Installation Guide 78-6461...-04 Installing the Switch in a Rack Chapter 2 Installation • For a 19-inch or a telco rack, use the ...
Hardware Installation Guide
Page 57
Chapter 2 Installation Installing the Switch in a Rack Figure 2-5 Attaching Brackets on Catalyst 2912MF XL, 2924M XL, and 2924M XL DC Modular Switches (Front-Panel Forward) Phillips flat-head screws 19" configuration Phillips truss-head screws 12 MODE 1X 2X 3X 4X 5X 6X 7X 23" and 24" configuration 12 MODE 1X 2X 3X 4X 5X 6X 7X 47297 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-13
Chapter 2 Installation Installing the Switch in a Rack Figure 2-5 Attaching Brackets on Catalyst 2912MF XL, 2924M XL, and 2924M XL DC Modular Switches (Front-Panel Forward) Phillips flat-head screws 19" configuration Phillips truss-head screws 12 MODE 1X 2X 3X 4X 5X 6X 7X 23" and 24" configuration 12 MODE 1X 2X 3X 4X 5X 6X 7X 47297 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-13
Hardware Installation Guide
Page 58
Installing the Switch in a Rack Chapter 2 Installation Figure 2-6 Attaching Brackets on Catalyst 2912 XL, 2924C XL, and 2924 XL Fixed-Port Switches (Rear-Panel Forward) 19" configuration Phillips flat-head screws 23" and 24" configuration Phillips truss-head screws 47298 2-14 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04
Installing the Switch in a Rack Chapter 2 Installation Figure 2-6 Attaching Brackets on Catalyst 2912 XL, 2924C XL, and 2924 XL Fixed-Port Switches (Rear-Panel Forward) 19" configuration Phillips flat-head screws 23" and 24" configuration Phillips truss-head screws 47298 2-14 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04
Hardware Installation Guide
Page 59
....0A0AT/2IN050G0--26400HVZ~ Phillips truss-head screws 23" and 24" configuration Figure 2-8 Attaching Brackets for Telco Racks 47299 DC INPUT 21.00A0-/11R2.0A0AT/2IN050G0--26400HVZ~ Phillips flat-head screws 71236 Note Only the Catalyst 2912MF XL, Catalyst 2924M XL, and Catalyst 2924M XL DC switches can be mounted in telco racks. 78-6461-04...
....0A0AT/2IN050G0--26400HVZ~ Phillips truss-head screws 23" and 24" configuration Figure 2-8 Attaching Brackets for Telco Racks 47299 DC INPUT 21.00A0-/11R2.0A0AT/2IN050G0--26400HVZ~ Phillips flat-head screws 71236 Note Only the Catalyst 2912MF XL, Catalyst 2924M XL, and Catalyst 2924M XL DC switches can be mounted in telco racks. 78-6461-04...
Hardware Installation Guide
Page 60
... a bracket to the opposite side of the switch. The mounting brackets shipped with a Catalyst 2900 LRE XL switch cannot support the switch in a 23- If you install the switch in a 19-inch rack. Installing the Switch in a Rack Chapter 2 Installation Attaching the Brackets to the switch. or 24-inch rack, the switch sags towards the rear of the bracket...
... a bracket to the opposite side of the switch. The mounting brackets shipped with a Catalyst 2900 LRE XL switch cannot support the switch in a 23- If you install the switch in a 19-inch rack. Installing the Switch in a Rack Chapter 2 Installation Attaching the Brackets to the switch. or 24-inch rack, the switch sags towards the rear of the bracket...
Hardware Installation Guide
Page 61
Chapter 2 Installation Installing the Switch in a Rack Figure 2-9 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Front-Panel Forward) Phillips flat-head screws Phillips truss-head screws 19" configuration INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 23" and 24" configuration INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 54728 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-17
Chapter 2 Installation Installing the Switch in a Rack Figure 2-9 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Front-Panel Forward) Phillips flat-head screws Phillips truss-head screws 19" configuration INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 23" and 24" configuration INPUT OUTPUT PWR PWR RESET TEMP FAN 9X 10X 11X 12X 54728 78-6461-04 Catalyst 2900 Series XL Hardware Installation Guide 2-17
Hardware Installation Guide
Page 62
Installing the Switch in a Rack Chapter 2 Installation Figure 2-10 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Rear-Panel Forward 19" configuration Phillips flat-head screws 54824 Phillips truss-head screws 23" and 24" configuration Mounting the Switch in a Rack After the brackets are attached to the switch, use the four supplied number-12 Phillips machine screws to securely attach the brackets to the rack, as shown in Figure 2-11. 2-18 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04
Installing the Switch in a Rack Chapter 2 Installation Figure 2-10 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Rear-Panel Forward 19" configuration Phillips flat-head screws 54824 Phillips truss-head screws 23" and 24" configuration Mounting the Switch in a Rack After the brackets are attached to the switch, use the four supplied number-12 Phillips machine screws to securely attach the brackets to the rack, as shown in Figure 2-11. 2-18 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-04
Hardware Installation Guide
Page 160
...RJ-45 console port 1-19 rollover cable 2-43, B-6 identifying B-6 pinouts B-8 RPS 300 connector 1-23 supported switches 1-22 warning C-2 RPS 600 connector 1-22 LED 1-13 supported switches 1-22 warning C-1 RPS LED 1-13 to 1-14 S safety C-1 SC connectors B-2 SPEED LED 1-15 ...switch powering on 2-24 switched ports, module 1-8 System LED 1-12 T telco racks 2-15 telephone network power warning See TN power warning C-10 temperature maximum for installation 2-7, A-2 warning C-9 temperature warning C-9 terminal, connecting to switch 2-42 terminal adapter pinouts RH-45-to-RJ-45 B-7 IN-6 Catalyst...
...RJ-45 console port 1-19 rollover cable 2-43, B-6 identifying B-6 pinouts B-8 RPS 300 connector 1-23 supported switches 1-22 warning C-2 RPS 600 connector 1-22 LED 1-13 supported switches 1-22 warning C-1 RPS LED 1-13 to 1-14 S safety C-1 SC connectors B-2 SPEED LED 1-15 ...switch powering on 2-24 switched ports, module 1-8 System LED 1-12 T telco racks 2-15 telephone network power warning See TN power warning C-10 temperature maximum for installation 2-7, A-2 warning C-9 temperature warning C-9 terminal, connecting to switch 2-42 terminal adapter pinouts RH-45-to-RJ-45 B-7 IN-6 Catalyst...