User Guide
Page 4
... Snooping to Reduce Multicast Traffic Passing through your Switch 60 5.12 How to Configure Access Control List (ACL) for Packets Filtering 63 5.13 How to Reset the Switch via the Console Port 66 Chapter 6 Troubleshooting...69 6.1 Power, Hardware Connections, and LEDs 69 6.2 Switch Access and Login ...70 Appendix A Legal Information...73...
... Snooping to Reduce Multicast Traffic Passing through your Switch 60 5.12 How to Configure Access Control List (ACL) for Packets Filtering 63 5.13 How to Reset the Switch via the Console Port 66 Chapter 6 Troubleshooting...69 6.1 Power, Hardware Connections, and LEDs 69 6.2 Switch Access and Login ...70 Appendix A Legal Information...73...
User Guide
Page 9
GS1910/XGS1910 Series User's Guide 9 Restoring an earlier working configuration may be useful if the device becomes unstable or even crashes. Chapter 1 Getting to totally re-configure the Switch. You could simply restore your password, you would not have to reset the Switch to restore it). If you forget your last configuration. If...
GS1910/XGS1910 Series User's Guide 9 Restoring an earlier working configuration may be useful if the device becomes unstable or even crashes. Chapter 1 Getting to totally re-configure the Switch. You could simply restore your password, you would not have to reset the Switch to restore it). If you forget your last configuration. If...
User Guide
Page 31
... where you can also view what kind of the Ethernet connections on the XGS1910-24 or XGS1910-48. This link takes you to the Switch. This link takes you to a screen where you can to reset the Switch back to a screen where you can reboot the system without turning ... Upload Image Select VeriPHY® cable diagnostics provide extensive network cable information such as cable length, termination status, and open/short fault location. GS1910/XGS1910 Series User's Guide 31 Configuration Backup Upload This screen is . This link takes you to a screen where you can view the LLDP...
... where you can also view what kind of the Ethernet connections on the XGS1910-24 or XGS1910-48. This link takes you to the Switch. This link takes you to a screen where you can to reset the Switch back to a screen where you can reboot the system without turning ... Upload Image Select VeriPHY® cable diagnostics provide extensive network cable information such as cable length, termination status, and open/short fault location. GS1910/XGS1910 Series User's Guide 31 Configuration Backup Upload This screen is . This link takes you to a screen where you can view the LLDP...
User Guide
Page 33
...Using Mirroring • How to Use IGMP Snooping to Reduce Multicast Traffic Passing through your network. Figure 27 Initial Setup Example: Management IP Address GS1910/XGS1910 Series User's Guide 33 The tutorials include: • How to Change Switch Management IP Address • How to Configure Login Accounts ... to Do Port Isolation in your Switch • How to Configure Access Control List (ACL) for Packets Filtering • How to Reset the Switch via the Console Port 5.1 How to Change Switch Management IP Address The default management IP address of the Switch is 192.168.1.1....
...Using Mirroring • How to Use IGMP Snooping to Reduce Multicast Traffic Passing through your network. Figure 27 Initial Setup Example: Management IP Address GS1910/XGS1910 Series User's Guide 33 The tutorials include: • How to Change Switch Management IP Address • How to Configure Login Accounts ... to Do Port Isolation in your Switch • How to Configure Access Control List (ACL) for Packets Filtering • How to Reset the Switch via the Console Port 5.1 How to Change Switch Management IP Address The default management IP address of the Switch is 192.168.1.1....
User Guide
Page 36
... allows you to create various "snap shots" of 10 to do system maintenance, such as configuring login accounts, uploading firmware or resetting to the factory defaults. To change the access privilege level for each feature group, go to Configuration > Security > Switch > Privilege... Levels. 5.3 How to display the File Download screen. 36 GS1910/XGS1910 Series User's Guide To backup your configuration file, 1 Click Maintenance > Configuration > Save and click Save Configuration. 2 Click Save to Manage...
... allows you to create various "snap shots" of 10 to do system maintenance, such as configuring login accounts, uploading firmware or resetting to the factory defaults. To change the access privilege level for each feature group, go to Configuration > Security > Switch > Privilege... Levels. 5.3 How to display the File Download screen. 36 GS1910/XGS1910 Series User's Guide To backup your configuration file, 1 Click Maintenance > Configuration > Save and click Save Configuration. 2 Click Save to Manage...
User Guide
Page 66
...seconds - This means that does NOT matched the specified ACL policy. 5.13 How to Reset the Switch via the Console Port If you lock yourself (and others) from 0x40080000-0x4017ffff message. 66 GS1910/XGS1910 Series User's Guide When you reconnect the Switch's power, you will lose all ...previous configurations and the speed of 9600bps with 8 data bit, no parity, one stop the automatic boot and then type default. 4 Type reset after the "Erase from the...
...seconds - This means that does NOT matched the specified ACL policy. 5.13 How to Reset the Switch via the Console Port If you lock yourself (and others) from 0x40080000-0x4017ffff message. 66 GS1910/XGS1910 Series User's Guide When you reconnect the Switch's power, you will lose all ...previous configurations and the speed of 9600bps with 8 data bit, no parity, one stop the automatic boot and then type default. 4 Type reset after the "Erase from the...
User Guide
Page 67
...self-test: ... Zero Sweep Done DDR SDRAM: Testing [0x800214d8-0x87fe1000] - RedBoot> fis load -d managed Image loaded from 0x40080000-0x4017ffff RedBoot> reset +M25PXX : Init device with JEDEC ID 0xC22018. You are welcome to change it and/or distribute copies of it under certain conditions. Platform: ...source code and full license terms must have been made available to you . Erase from 0x80040000-0x806a4d20 RedBoot> go Username: GS1910/XGS1910 Series User's Guide 67 Under the license terms, RedBoot's source code and full license terms must have been made available to ...
...self-test: ... Zero Sweep Done DDR SDRAM: Testing [0x800214d8-0x87fe1000] - RedBoot> fis load -d managed Image loaded from 0x40080000-0x4017ffff RedBoot> reset +M25PXX : Init device with JEDEC ID 0xC22018. You are welcome to change it and/or distribute copies of it under certain conditions. Platform: ...source code and full license terms must have been made available to you . Erase from 0x80040000-0x806a4d20 RedBoot> go Username: GS1910/XGS1910 Series User's Guide 67 Under the license terms, RedBoot's source code and full license terms must have been made available to ...
User Guide
Page 70
...does not work , you changed the IP address, use the new IP address. 70 GS1910/XGS1910 Series User's Guide Chapter 6 Troubleshooting One of the LEDs does not behave as expected. 1 Make sure you have to reset the device to its factory defaults. I forgot the username and/or password. 1 The... default username is admin and the default password is 192.168.1.1. • If you have to reset the device to its factory defaults.
...does not work , you changed the IP address, use the new IP address. 70 GS1910/XGS1910 Series User's Guide Chapter 6 Troubleshooting One of the LEDs does not behave as expected. 1 Make sure you have to reset the device to its factory defaults. I forgot the username and/or password. 1 The... default username is admin and the default password is 192.168.1.1. • If you have to reset the device to its factory defaults.
User Guide
Page 71
... 6 If the problem continues, contact the vendor. GS1910/XGS1910 Series User's Guide 71 Chapter 6 Troubleshooting • If you changed the IP address and have forgotten it . 3 Disconnect and re-connect the cord to the Switch. 4 If this step.) 5 Reset the device to access the Switch with the default ... not belonging to the secured client set cannot get permission to my Switch via HTTP. See Section 3.3 on . 2 If you have to reset the device to its factory defaults, and try to its factory defaults. There is 1234. To avoid unauthorized access, configure the secured client setting...
... 6 If the problem continues, contact the vendor. GS1910/XGS1910 Series User's Guide 71 Chapter 6 Troubleshooting • If you changed the IP address and have forgotten it . 3 Disconnect and re-connect the cord to the Switch. 4 If this step.) 5 Reset the device to access the Switch with the default ... not belonging to the secured client set cannot get permission to my Switch via HTTP. See Section 3.3 on . 2 If you have to reset the device to its factory defaults, and try to its factory defaults. There is 1234. To avoid unauthorized access, configure the secured client setting...