Use & Care Guide
Page 1
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. LI3YMB/W10292167C www.whirlpool.com or www.whirlpool.ca HOTTE D'EXTRACTION À MONTAGE MURAL DE 30" ET 36" (76,2 CM ET 91,4 CM) Instructions d'installation et Guide d'utilisation et d'entretien Au Canada, pour ... 1-800-807-6777 ou visiter notre site web à www.whirlpool.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. ® 30" AND 36" (76.2 CM AND 91.4 CM) WALLMOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features...
POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT. LI3YMB/W10292167C www.whirlpool.com or www.whirlpool.ca HOTTE D'EXTRACTION À MONTAGE MURAL DE 30" ET 36" (76,2 CM ET 91,4 CM) Instructions d'installation et Guide d'utilisation et d'entretien Au Canada, pour ... 1-800-807-6777 ou visiter notre site web à www.whirlpool.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. ® 30" AND 36" (76.2 CM AND 91.4 CM) WALLMOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features...
Use & Care Guide
Page 2
...Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13...24 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you and others are not followed. 2 This ...
...Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13...24 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you and others are not followed. 2 This ...
Use & Care Guide
Page 4
... from strong draft areas, such as windows, doors and strong heating vents. Have a qualified technician install the range hood. Canopy hood location should be used. Recirculation Kit Part Number W10294733 is determined by ceiling height. Check that are included. ■...duct - It is factory set Parts needed ■ Level ■ Drill with installation clearances specified on the rear wall of this range hood must be sealed. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions ...
... from strong draft areas, such as windows, doors and strong heating vents. Have a qualified technician install the range hood. Canopy hood location should be used. Recirculation Kit Part Number W10294733 is determined by ceiling height. Check that are included. ■...duct - It is factory set Parts needed ■ Level ■ Drill with installation clearances specified on the rear wall of this range hood must be sealed. INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions ...
Use & Care Guide
Page 5
... than specified CFM of the thermal break. A 6" (15.2 cm) round vent system is 6" (15.2 cm) round. The hood exhaust opening around the cap. ■ The size of the range hood and the cooking surface. Vent system can be adjusted for ceilings between 7' 4" (2.24 m) and 9' 9" (2.97 m). *NOTE:... kept to a minimum to where the vent system enters the heated portion of straight vent between 7' 4" (2.25 m) and 9' 9" (2.97 m) with the range hood. Vent and power supply cable entry location 20" (50.8 cm)* min. Plastic or metal foil vent is used. ■ Do not install 2 elbows together...
... than specified CFM of the thermal break. A 6" (15.2 cm) round vent system is 6" (15.2 cm) round. The hood exhaust opening around the cap. ■ The size of the range hood and the cooking surface. Vent system can be adjusted for ceilings between 7' 4" (2.24 m) and 9' 9" (2.97 m). *NOTE:... kept to a minimum to where the vent system enters the heated portion of straight vent between 7' 4" (2.25 m) and 9' 9" (2.97 m) with the range hood. Vent and power supply cable entry location 20" (50.8 cm)* min. Plastic or metal foil vent is used. ■ Do not install 2 elbows together...
Use & Care Guide
Page 6
...; elbow = 5.0 ft (1.5 m) 1 - The model/serial plate is adequate and in conformance with the rating of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform to the pigtail leads. 2. Maximum equivalent vent length is required. ■ If the house has aluminum wiring, follow the procedure...is not possible to vent cooking fumes and vapors to the added section of system = 13.0 ft (3.9 m) 6 Connect the aluminum wiring to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector.
...; elbow = 5.0 ft (1.5 m) 1 - The model/serial plate is adequate and in conformance with the rating of the appliance as specified on the rear wall of the range hood. ■ Wire sizes must conform to the pigtail leads. 2. Maximum equivalent vent length is required. ■ If the house has aluminum wiring, follow the procedure...is not possible to vent cooking fumes and vapors to the added section of system = 13.0 ft (3.9 m) 6 Connect the aluminum wiring to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector.
Use & Care Guide
Page 7
...2. INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that surface. 9. Mark centers of the fastener locations through the template to slide range hood into , additional wall framing supports may be required. Disconnect power. 2. Drill 4.8 mm) pilot holes at this location. 3. Select ... cm) hole at all openings. 7 Ceiling B. Fastener locations C. Determine the required height for assembling the range hood. There must be installed before hood is proper clearance within the ceiling or wall for a gas cooking surface, and a suggested maximum of template with...
...2. INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that surface. 9. Mark centers of the fastener locations through the template to slide range hood into , additional wall framing supports may be required. Disconnect power. 2. Drill 4.8 mm) pilot holes at this location. 3. Select ... cm) hole at all openings. 7 Ceiling B. Fastener locations C. Determine the required height for assembling the range hood. There must be installed before hood is proper clearance within the ceiling or wall for a gas cooking surface, and a suggested maximum of template with...
Use & Care Guide
Page 8
... Reassemble the air deflector to the measured size (X). 4. Seal connections with 4 - A B C A. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of the air deflector. 6. Mounting slots C. Install 2 - 5 x 45 mm lower...screws and tighten. Remove the air deflector. 5. A B X C D E A A. Mounting screws B. See "Range Hood Care" section. 3. Fit vent system over the exhaust outlet from the bottom of the hood outlet. Assemble the air deflector with the duct cover bracket with vent clamps. Vent clamp C. Assembly screws B. C...
... Reassemble the air deflector to the measured size (X). 4. Seal connections with 4 - A B C A. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of the air deflector. 6. Mounting slots C. Install 2 - 5 x 45 mm lower...screws and tighten. Remove the air deflector. 5. A B X C D E A A. Mounting screws B. See "Range Hood Care" section. 3. Fit vent system over the exhaust outlet from the bottom of the hood outlet. Assemble the air deflector with the duct cover bracket with vent clamps. Vent clamp C. Assembly screws B. C...
Use & Care Guide
Page 10
... by pressing the desired blower speed button. Secure the bottom of the canopy. RANGE HOOD USE The range hood is complete to remove smoke, cooking vapors and odors from your new range hood, read the "Range Hood Use" section. Glass canopy E. Blower speed maximum button C Operating the light...1. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the "Range Hood Care" section. 3. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is designed to clear all smoke ...
... by pressing the desired blower speed button. Secure the bottom of the canopy. RANGE HOOD USE The range hood is complete to remove smoke, cooking vapors and odors from your new range hood, read the "Range Hood Use" section. Glass canopy E. Blower speed maximum button C Operating the light...1. For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the "Range Hood Care" section. 3. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is designed to clear all smoke ...
Use & Care Guide
Page 11
...and wipe dry. 5. Remove lamp cover and set lamp cover and the screw aside. 4. A Turn off the range hood and allow the lamp to handle bulb. Remove metal grease filter from range hood. Always wipe dry to the following instructions. See "Metal Grease Filter" in this section. To replace charcoal filter:... release handle and then pulling down the filter. Push up to the metal filter. Replace lamp cover and reinstall screw. 6. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to avoid water marks. Bend spring clips back into place.
...and wipe dry. 5. Remove lamp cover and set lamp cover and the screw aside. 4. A Turn off the range hood and allow the lamp to handle bulb. Remove metal grease filter from range hood. Always wipe dry to the following instructions. See "Metal Grease Filter" in this section. To replace charcoal filter:... release handle and then pulling down the filter. Push up to the metal filter. Replace lamp cover and reinstall screw. 6. RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to avoid water marks. Bend spring clips back into place.
Installation Guide
Page 1
...AND 91.4 CM) WALLMOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call : 1-800-807-6777 or visit our website at... In Canada, call : 1-800-253-1301. FOR RESIDENTIAL USE ONLY. www.whirlpool.com or www.whirlpool.ca HOTTE D'EXTRACTION À...et Guide d'utilisation et d'entretien Au Canada, pour assistance, installation ou service, composer 1-800-807-6777 ou visiter notre site web à www.whirlpool.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
...AND 91.4 CM) WALLMOUNT CANOPY RANGE HOOD Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call : 1-800-807-6777 or visit our website at... In Canada, call : 1-800-253-1301. FOR RESIDENTIAL USE ONLY. www.whirlpool.com or www.whirlpool.ca HOTTE D'EXTRACTION À...et Guide d'utilisation et d'entretien Au Canada, pour assistance, installation ou service, composer 1-800-807-6777 ou visiter notre site web à www.whirlpool.ca Table of Contents/Table des matières 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
Installation Guide
Page 2
... Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13... SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what the potential hazard is the safety alert...
... Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete Installation 10 RANGE HOOD USE 10 Range Hood Controls 10 RANGE HOOD CARE 11 Cleaning 11 WIRING DIAGRAM 12 ASSISTANCE OR SERVICE 13 In the U.S.A 13... SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 27 RANGE HOOD SAFETY Your safety and the safety of injury, and tell you what the potential hazard is the safety alert...
Installation Guide
Page 4
...Requirements IMPORTANT: Observe all parts are shown must be sealed. Check that are included. ■ Hood canopy assembly with installation clearances specified on the rear wall of this range hood must conform to order. ■ 6" (15.2 cm) dia. Grounded electrical outlet is not...Cabinet opening dimensions that all governing codes and ordinances. For Mobile Home Installations The installation of the vent hood. Have a qualified technician install the range hood. Parts supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. ...
...Requirements IMPORTANT: Observe all parts are shown must be sealed. Check that are included. ■ Hood canopy assembly with installation clearances specified on the rear wall of this range hood must conform to order. ■ 6" (15.2 cm) dia. Grounded electrical outlet is not...Cabinet opening dimensions that all governing codes and ordinances. For Mobile Home Installations The installation of the vent hood. Have a qualified technician install the range hood. Parts supplied Remove parts from strong draft areas, such as windows, doors and strong heating vents. ...
Installation Guide
Page 5
... be adjusted for ceilings between 7' 4" (2.25 m) and 9' 5" (2.87 m) with the range hood. Plastic or metal foil vent is not recommended. ■ The length of vent system and number of the range hood and the cooking surface. If the roof or wall cap has a damper, do not use ...Chimney Extension Kit Part Number W10294735 is a minimum of 24" (61 cm) of straight vent between 7' 4" (2.25 m) and 9' 9" (2.97 m) with the range hood. ■ Use caulking to seal exterior wall or roof opening is factory set for specific requirements in your dealer or an authorized parts distributor. For...
... be adjusted for ceilings between 7' 4" (2.25 m) and 9' 5" (2.87 m) with the range hood. Plastic or metal foil vent is not recommended. ■ The length of vent system and number of the range hood and the cooking surface. If the roof or wall cap has a damper, do not use ...Chimney Extension Kit Part Number W10294735 is a minimum of 24" (61 cm) of straight vent between 7' 4" (2.25 m) and 9' 9" (2.97 m) with the range hood. ■ Use caulking to seal exterior wall or roof opening is factory set for specific requirements in your dealer or an authorized parts distributor. For...
Installation Guide
Page 6
... and ordinances. If codes permit and a separate ground wire is used, it is located behind the filter on the rear wall of the range hood. ■ Wire sizes must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the pigtail... electrical circuit is 35 ft (10.7 m). A copy of the system you need, add the equivalent feet (meters) for joining copper to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Connect a section of system = 13.0 ft (3.9 m) 6...
... and ordinances. If codes permit and a separate ground wire is used, it is located behind the filter on the rear wall of the range hood. ■ Wire sizes must conform with local codes and industry accepted wiring practices. ■ Wire sizes and connections must conform to the pigtail... electrical circuit is 35 ft (10.7 m). A copy of the system you need, add the equivalent feet (meters) for joining copper to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Connect a section of system = 13.0 ft (3.9 m) 6...
Installation Guide
Page 7
...¹⁄₄" (6.4 mm) Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. Attach vent cover bracket to wall flush to move and install range hood. Centerline B. Fastener locations C. Determine and make all locations where screws are being installed into... wood. INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that surface. 9. Determine which venting method to slide range hood into , additional wall framing supports may be required. Leave a ¹⁄₄" (6.4 mm) gap between a minimum of ...
...¹⁄₄" (6.4 mm) Excessive Weight Hazard Use two or more people, lift range hood onto covered surface. Attach vent cover bracket to wall flush to move and install range hood. Centerline B. Fastener locations C. Determine and make all locations where screws are being installed into... wood. INSTALLATION INSTRUCTIONS Prepare Location ■ It is recommended that surface. 9. Determine which venting method to slide range hood into , additional wall framing supports may be required. Leave a ¹⁄₄" (6.4 mm) gap between a minimum of ...
Installation Guide
Page 8
... Exhaust outlet 3. Assembly screws B. Check that backdraft dampers work properly. Slide the duct onto the bottom of hood. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of the air deflector. 6. C B 2. Connect ...Air deflector C. Remove the grease filter. Assemble the air deflector with the duct cover bracket with 4 assembly screws. 8. Measure from the hood. 7. See "Range Hood Care" section. 3. X = length to the duct cover bracket with 4 - Reassemble the air deflector to cut vent duct D. ...
... Exhaust outlet 3. Assembly screws B. Check that backdraft dampers work properly. Slide the duct onto the bottom of hood. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of the air deflector. 6. C B 2. Connect ...Air deflector C. Remove the grease filter. Assemble the air deflector with the duct cover bracket with 4 assembly screws. 8. Measure from the hood. 7. See "Range Hood Care" section. 3. X = length to the duct cover bracket with 4 - Reassemble the air deflector to cut vent duct D. ...
Installation Guide
Page 10
... the light The On/Off light button controls both lights. Control panel D. Grease filter F. Lamp cover G. Complete Installation 1. See the "Range Hood Care" section. 2. Blower speed medium button E. Press once for On D and again for quiet operation. Grease filter release handle The BLOWER... cooking and allow it to operate several minutes after the cooking is designed to clear all smoke and odors from your new range hood, read the "Range Hood Use" section. Range Hood Controls A B C D E A. Secure the bottom of lamps may vary) H. H Operating the blower GF E A. Duct cover...
... the light The On/Off light button controls both lights. Control panel D. Grease filter F. Lamp cover G. Complete Installation 1. See the "Range Hood Care" section. 2. Blower speed medium button E. Press once for On D and again for quiet operation. Grease filter release handle The BLOWER... cooking and allow it to operate several minutes after the cooking is designed to clear all smoke and odors from your new range hood, read the "Range Hood Use" section. Range Hood Controls A B C D E A. Secure the bottom of lamps may vary) H. H Operating the blower GF E A. Duct cover...
Installation Guide
Page 11
...metal grease filter from metal grease filter. 3. Replace grease filters before calling service. 1. Push in this section. 2. Bend spring clips away from range hood. Replace lamp cover and reinstall screw. 6. Place charcoal filter into upper track. 4. Metal Grease Filter: Replacing a Lamp 1. Cleaning Method: ...lamp cover. Remove lamp cover and set lamp cover and the screw aside. 4. Reconnect power. 11 A Turn off the range hood and allow the lamp to avoid water marks. If new lamps do not operate, make sure the lamps are toward the front...
...metal grease filter from metal grease filter. 3. Replace grease filters before calling service. 1. Push in this section. 2. Bend spring clips away from range hood. Replace lamp cover and reinstall screw. 6. Place charcoal filter into upper track. 4. Metal Grease Filter: Replacing a Lamp 1. Cleaning Method: ...lamp cover. Remove lamp cover and set lamp cover and the screw aside. 4. Reconnect power. 11 A Turn off the range hood and allow the lamp to avoid water marks. If new lamps do not operate, make sure the lamps are toward the front...
Dimension Guide
Page 1
... (50.8 cm) 30" (76.2 cm) or 36" (91.4 cm) *For non-vented (recirculating) installations **For vented installations Because Whirlpool Corporation policy includes a continuous commitment to change materials and specifications without notice. wall cap 8 ft (2.4 m) straight Length of the system you need...= 0.0 ft (0.0 m) = 8.0 ft (2.4 m) = 13.0 ft (3.9 m) A. ® 30" and 36" (76.2 cm and 91.4 cm) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS GXW6530DX GXW6536DX ELECTRICAL REQUIREMENTS • A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 6" (15.2 cm) round.
... (50.8 cm) 30" (76.2 cm) or 36" (91.4 cm) *For non-vented (recirculating) installations **For vented installations Because Whirlpool Corporation policy includes a continuous commitment to change materials and specifications without notice. wall cap 8 ft (2.4 m) straight Length of the system you need...= 0.0 ft (0.0 m) = 8.0 ft (2.4 m) = 13.0 ft (3.9 m) A. ® 30" and 36" (76.2 cm and 91.4 cm) Wall-Mount Canopy Range Hood PRODUCT MODEL NUMBERS GXW6530DX GXW6536DX ELECTRICAL REQUIREMENTS • A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 6" (15.2 cm) round.
Dimension Guide
Page 2
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are adjustable and designed to change without notice. Instructions packed with the range hood. The chimney extension replaces the upper chimney shipped with product. For complete details, ...26/10 For Non-Vented (recirculating) Installations * NOTE: The range hood chimneys are for ceilings between 7' 4" (2.25 m) and 9' 5" (2.87 m) with vent slots not showing and between the bottom of the range hood and the cooking surface. Specifications subject to cooking surface Centerline Cooking ...
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are adjustable and designed to change without notice. Instructions packed with the range hood. The chimney extension replaces the upper chimney shipped with product. For complete details, ...26/10 For Non-Vented (recirculating) Installations * NOTE: The range hood chimneys are for ceilings between 7' 4" (2.25 m) and 9' 5" (2.87 m) with vent slots not showing and between the bottom of the range hood and the cooking surface. Specifications subject to cooking surface Centerline Cooking ...