XE-A203 Operation Manual in English and Spanish
Page 7
... OP MA The mode switch has these settings: OFF: This mode locks all register operations. (AC power turns off.) No change occurs to page 39. X1/Z1: To take the X/Z report for various ... Y CHK CH W Z MDSE #/TM SBTL SBTL CA/AT/NS The small characters on account key RCPT /PO Receipt print/Paid-out key • Decimal point key CL Clear key TAX1 TAX2 SHIFT SHIFT Tax 1 and 2 shift keys AUTO Automatic... key CLK# Clerk code entry key ~ 17 1 32 16 Department keys #/TM Non-add code/Time display SBTL /Subtotal key CA/AT/NS Total/Amount tender /No sale key 5 OP X/Z: To take...
... OP MA The mode switch has these settings: OFF: This mode locks all register operations. (AC power turns off.) No change occurs to page 39. X1/Z1: To take the X/Z report for various ... Y CHK CH W Z MDSE #/TM SBTL SBTL CA/AT/NS The small characters on account key RCPT /PO Receipt print/Paid-out key • Decimal point key CL Clear key TAX1 TAX2 SHIFT SHIFT Tax 1 and 2 shift keys AUTO Automatic... key CLK# Clerk code entry key ~ 17 1 32 16 Department keys #/TM Non-add code/Time display SBTL /Subtotal key CA/AT/NS Total/Amount tender /No sale key 5 OP X/Z: To take...
XE-A203 Operation Manual in English and Spanish
Page 8
...Depending on programming.) : Appears when the voltage of the installed batteries is smaller than the sales amount. When you have registered ten times, the display will show "0."(2 → 3 ..... 9 → 0 → 1 → 2 ... )...C c : Appears when a transaction is finalized by pressing the , or key. : Appears when the change due amount is displayed. : May appear in the OFF status. To lock it , turn 90 degrees ... right below the tenth place when power save mode is effective. : Appears when the print roller arm is not locked. : Appears when the paper is pressed to page 69 ...
...Depending on programming.) : Appears when the voltage of the installed batteries is smaller than the sales amount. When you have registered ten times, the display will show "0."(2 → 3 ..... 9 → 0 → 1 → 2 ... )...C c : Appears when a transaction is finalized by pressing the , or key. : Appears when the change due amount is displayed. : May appear in the OFF status. To lock it , turn 90 degrees ... right below the tenth place when power save mode is effective. : Appears when the print roller arm is not locked. : Appears when the paper is pressed to page 69 ...
XE-A203 Operation Manual in English and Spanish
Page 11
... Function Selection Programming 2" section for details (page 27). 9 Refer to "Language selection" in "Various Function Selection Programming 1" section (Job code 6) for changing the printing style. 5 Programming date, time and tax The cash register provides text languages of the inner cover, and F replace the printer cover. If the paper end does not come out, open the...
... Function Selection Programming 2" section for details (page 27). 9 Refer to "Language selection" in "Various Function Selection Programming 1" section (Job code 6) for changing the printing style. 5 Programming date, time and tax The cash register provides text languages of the inner cover, and F replace the printer cover. If the paper end does not come out, open the...
XE-A203 Operation Manual in English and Spanish
Page 12
... You must change the setting, the maximum number of PLU code will decrease from 1200 to 200. • Text programming for clerk name, department items, PLU/sub-department items, logo messages printed on the top or bottom of clerk to be trained Department programming: The cash register is commonly used... • Preset amount for • Preset rates for % & You do not have to re-enter every time. • Amount entry digit limit for AUTO key • Online time out setting • Specification of receipts, function texts and foreign currency symbol • Split pricing entry This is ...
... You must change the setting, the maximum number of PLU code will decrease from 1200 to 200. • Text programming for clerk name, department items, PLU/sub-department items, logo messages printed on the top or bottom of clerk to be trained Department programming: The cash register is commonly used... • Preset amount for • Preset rates for % & You do not have to re-enter every time. • Amount entry digit limit for AUTO key • Online time out setting • Specification of receipts, function texts and foreign currency symbol • Split pricing entry This is ...
XE-A203 Operation Manual in English and Spanish
Page 14
...opened. 8. Tear off the receipt and give it to 6.25%.) Print Graphic logo Date/Time/Clerk code number Register number /Consecutive number/Clerk name Items Price Merchandise subtotal Tax amount Not printed when non-taxable items only are sold. For operation details, please ...cash. BASIC SALES ENTRY 1 Basic Sales Entry Example Listed below is automatically selected just after initialization of the cash register. Turn the mode switch to display the amount due. Close the drawer. Tax status (T1: taxable 1) Total quantity Total amount Cash tendering/amount received Change...
...opened. 8. Tear off the receipt and give it to 6.25%.) Print Graphic logo Date/Time/Clerk code number Register number /Consecutive number/Clerk name Items Price Merchandise subtotal Tax amount Not printed when non-taxable items only are sold. For operation details, please ...cash. BASIC SALES ENTRY 1 Basic Sales Entry Example Listed below is automatically selected just after initialization of the cash register. Turn the mode switch to display the amount due. Close the drawer. Tax status (T1: taxable 1) Total quantity Total amount Cash tendering/amount received Change...
XE-A203 Operation Manual in English and Spanish
Page 15
... a mode is changed with the mode key. Power Save Mode The register will produce a receipt. Contact your register is in the MGR mode. This key toggles the receipt printing status ON and OFF... will print reports regardless of summary receipt print. To issue a receipt when receipt ON/OFF function is voided (treated as a cash sale. 13 When your register goes to OFF: If your register will...you finalized a transaction with a warning beep and the l error symbol " " on the pre-programmed time limit (by a key entry, its key entry is issued by pressing the key and take proper ...
... a mode is changed with the mode key. Power Save Mode The register will produce a receipt. Contact your register is in the MGR mode. This key toggles the receipt printing status ON and OFF... will print reports regardless of summary receipt print. To issue a receipt when receipt ON/OFF function is voided (treated as a cash sale. 13 When your register goes to OFF: If your register will...you finalized a transaction with a warning beep and the l error symbol " " on the pre-programmed time limit (by a key entry, its key entry is issued by pressing the key and take proper ...
XE-A203 Operation Manual in English and Spanish
Page 29
...example 08262006 s (Aug. 26, 2006) Print Date You can program for programming 1. Program necessary items into the cash register. Check to "Various Function Selection Programming 1" section (Job code 61). 27 Every time you program an item, the cash register will print the setting. BASIC FUNCTION PROGRAMMING (For Quick..." indicates the parameter which must first program necessary items so that the cash register suits your sales manner. If necessary, issue programming reports for your reference. To change the format, refer to see whether a paper roll is not enough paper...
...example 08262006 s (Aug. 26, 2006) Print Date You can program for programming 1. Program necessary items into the cash register. Check to "Various Function Selection Programming 1" section (Job code 61). 27 Every time you program an item, the cash register will print the setting. BASIC FUNCTION PROGRAMMING (For Quick..." indicates the parameter which must first program necessary items so that the cash register suits your sales manner. If necessary, issue programming reports for your reference. To change the format, refer to see whether a paper roll is not enough paper...
XE-A203 Operation Manual in English and Spanish
Page 30
...a Parish tax) or a hospitality tax, the register can also enter tax manually. Time(max. 4 digits in 24-hour format) s Key operation example 1430 s Print Time In the display, current time is zero @ Lowest taxable amount (0.01 to program Tax 1. The cash register comes with ringing sales transactions, you program the ... is acceptable in your state. For example, when the time is set to calculate these separate taxes. When you must first change the tax system, then program the tax rate or tax table and quantity for PM time " " will be programmed to 2:30 PM, enter 1430...
...a Parish tax) or a hospitality tax, the register can also enter tax manually. Time(max. 4 digits in 24-hour format) s Key operation example 1430 s Print Time In the display, current time is zero @ Lowest taxable amount (0.01 to program Tax 1. The cash register comes with ringing sales transactions, you program the ... is acceptable in your state. For example, when the time is set to calculate these separate taxes. When you must first change the tax system, then program the tax rate or tax table and quantity for PM time " " will be programmed to 2:30 PM, enter 1430...
XE-A203 Operation Manual in English and Spanish
Page 59
... not want to skip, change the programming. (Refer to "Print format" of Reading (X) and Resetting (Z) Reports X1 and Z1 reports: Daily sales reports X2 and Z2 reports: Periodic (monthly) consolidation reports When you take a X or Z report, turn the mode switch to the MGR position. It does not affect the register's memory. • Use...
... not want to skip, change the programming. (Refer to "Print format" of Reading (X) and Resetting (Z) Reports X1 and Z1 reports: Daily sales reports X2 and Z2 reports: Periodic (monthly) consolidation reports When you take a X or Z report, turn the mode switch to the MGR position. It does not affect the register's memory. • Use...
Service Manual
Page 4
...tenth place when power save mode is effective. : Appears when the print roller arm is not locked. : Appears when the paper is not set or out. When you have registered ten times, the display will show "0." (2 3 3 ..... 9 3 ...hour-minute - Time: Appears in the OFF status. " " or hour-minute - Also appears right below the eighth and ninth places at "2" and incremental with each repeat. XE-A203U/XE-A203A SPECIFICATIONS ...finalized by pressing the [CA/AT/ NS], [CHK] or [CH] key. : Appears when the change occurs to toggle receipt state "ON" and "OFF" by pressing he [RCPT/PO] key. PGM...
...tenth place when power save mode is effective. : Appears when the print roller arm is not locked. : Appears when the paper is not set or out. When you have registered ten times, the display will show "0." (2 3 3 ..... 9 3 ...hour-minute - Time: Appears in the OFF status. " " or hour-minute - Also appears right below the eighth and ninth places at "2" and incremental with each repeat. XE-A203U/XE-A203A SPECIFICATIONS ...finalized by pressing the [CA/AT/ NS], [CHK] or [CH] key. : Appears when the change occurs to toggle receipt state "ON" and "OFF" by pressing he [RCPT/PO] key. PGM...
Service Manual
Page 5
...CASH], [CHECK], [CHARGE] key o C: Light up whenever the change due amount appears in the display. of station : 1 (Receipt or journal) • Validation : No. • Printing system : Line thermal...Printing capacity : max. 24 characters • Character size : 1.67mm (W) x 4.17mm (H) at the timing of thermal head heater elements 288 dots (4.75) 48 (288 dots) print area (max.24 characters) (4.75) 0.167 XE-A203U/XE... lines used to 0.08mm Nihon seisi thermal paper : TF50KS-E Oil thermal paper: PD150R, PD160R 3) Logo stamp • No 4) Printing area Number of key entry (by ...
...CASH], [CHECK], [CHARGE] key o C: Light up whenever the change due amount appears in the display. of station : 1 (Receipt or journal) • Validation : No. • Printing system : Line thermal...Printing capacity : max. 24 characters • Character size : 1.67mm (W) x 4.17mm (H) at the timing of thermal head heater elements 288 dots (4.75) 48 (288 dots) print area (max.24 characters) (4.75) 0.167 XE-A203U/XE... lines used to 0.08mm Nihon seisi thermal paper : TF50KS-E Oil thermal paper: PD150R, PD160R 3) Logo stamp • No 4) Printing area Number of key entry (by ...
Service Manual
Page 7
... Master resetting clears the entire memory and resumes initial values. OPTIONS 1. XE-A203U/XE-A203A OPTIONS - 5 - "L 0.00": Low battery (You have to change the batteries immediately.) After finalization "F 12.34": Battery is OK. ...machine does not work properly after the "POWER OFF". 10. SUPPLIES NO NAME 1 Thermal roll paper 4. SPECIAL SERVICE TOOLS NO NAME 1 USB Cable PARTS CODE TPAPR6656RC05 PARTS CODE...5 ROLLS/PACK PRICE RANK DESCRIPTION CHAPTER 3. The master reset can be operated at the timing of "F".) Note: "NO BATTERY": When the "NO BATTERY" is display, the master...
... Master resetting clears the entire memory and resumes initial values. OPTIONS 1. XE-A203U/XE-A203A OPTIONS - 5 - "L 0.00": Low battery (You have to change the batteries immediately.) After finalization "F 12.34": Battery is OK. ...machine does not work properly after the "POWER OFF". 10. SUPPLIES NO NAME 1 Thermal roll paper 4. SPECIAL SERVICE TOOLS NO NAME 1 USB Cable PARTS CODE TPAPR6656RC05 PARTS CODE...5 ROLLS/PACK PRICE RANK DESCRIPTION CHAPTER 3. The master reset can be operated at the timing of "F".) Note: "NO BATTERY": When the "NO BATTERY" is display, the master...
Service Manual
Page 14
...test mode by pressing any key is pressed, the date and time are in the proper sequence. If not, an error print is made . End print: yymmdd-hhmmss 107 (*) yy = year mm = month ... hh = hour mm = min ss = sec XE-A203U/XE-A203A TEST FUNCTION - 12 - If not, an error print is made . (*) The final key: "CA/AT" Key (*) XE-A203U/A203A sum check code: 3417 3 Display OP... The clock is pressed. m m s s (*) hh = hour mm = min ss = sec 4 Check that the positions are changed in accord with the key data accumulated until the final key (TL key) is displayed. 3 Display OP display: h h -mm ...
...test mode by pressing any key is pressed, the date and time are in the proper sequence. If not, an error print is made . End print: yymmdd-hhmmss 107 (*) yy = year mm = month ... hh = hour mm = min ss = sec XE-A203U/XE-A203A TEST FUNCTION - 12 - If not, an error print is made . (*) The final key: "CA/AT" Key (*) XE-A203U/A203A sum check code: 3417 3 Display OP... The clock is pressed. m m s s (*) hh = hour mm = min ss = sec 4 Check that the positions are changed in accord with the key data accumulated until the final key (TL key) is displayed. 3 Display OP display: h h -mm ...
Programming Guide
Page 4
... FUNCTION NO. /TEXT LOGO TEXT (It is skippd. : F 78 BILL F 79 EJ F 80 EJ END SHARP PRESENTS THE BEST ECR SHARP IS THE BEST #5 ...= 0 to 8 XE-A203/A213 PROGRAM MODE 2 - 1 When specifying a single time interval, PLU code,...LOGO FORMAT (JOB#12) EURO PROGRAMMING (JOB#13) EURO CHANGING DATE (Printed by Date format) (JOB#14) EURO CHANGING HOUR (JOB#15) FUNCTION SELECT2 (JOB#35) USB Timeout time... 0 to 7 (*2) : MEDIA PROGRAM A A: Footer print on Receipt A 0 No 0 1 Yes 1 B B: Entry of amount tenderd B 0 noncompulsory (Cash, check)/inhibit (Credit) 0 1 compulsory 1 C: LIMITATION...
... FUNCTION NO. /TEXT LOGO TEXT (It is skippd. : F 78 BILL F 79 EJ F 80 EJ END SHARP PRESENTS THE BEST ECR SHARP IS THE BEST #5 ...= 0 to 8 XE-A203/A213 PROGRAM MODE 2 - 1 When specifying a single time interval, PLU code,...LOGO FORMAT (JOB#12) EURO PROGRAMMING (JOB#13) EURO CHANGING DATE (Printed by Date format) (JOB#14) EURO CHANGING HOUR (JOB#15) FUNCTION SELECT2 (JOB#35) USB Timeout time... 0 to 7 (*2) : MEDIA PROGRAM A A: Footer print on Receipt A 0 No 0 1 Yes 1 B B: Entry of amount tenderd B 0 noncompulsory (Cash, check)/inhibit (Credit) 0 1 compulsory 1 C: LIMITATION...
Programming Guide
Page 9
... H: FRACTIONAL QUANTITY YES (3digits decimal place) NO A 0★ 1 B 0★ 1 C 0★ 1 D 0★ 1 E 0★ 1 F 0★ 1 G 0★ 1 H 0★ 1 XE-A203/A213 PROGRAM MODE 2 - 6 MRS = 00000001 A: PO in REG mode ENABLE DISABLE B: RA in REG mode ENABLE DISABLE C: SUBTOTAL VOID in REG mode ENABLE DISABLE D: INDIRECT...(6digits) -- It acts as the programmed key-sequence is changed by EURO CHANGING JOB and confirmed by depressing [#/TM/ST] (XE-A203V) or [#/ST] (XEA213V) key after a data that want to set at Z2 mode. It is entered. TIME) HH: Hour (00 to 23) MM: Minute (00...
... H: FRACTIONAL QUANTITY YES (3digits decimal place) NO A 0★ 1 B 0★ 1 C 0★ 1 D 0★ 1 E 0★ 1 F 0★ 1 G 0★ 1 H 0★ 1 XE-A203/A213 PROGRAM MODE 2 - 6 MRS = 00000001 A: PO in REG mode ENABLE DISABLE B: RA in REG mode ENABLE DISABLE C: SUBTOTAL VOID in REG mode ENABLE DISABLE D: INDIRECT...(6digits) -- It acts as the programmed key-sequence is changed by EURO CHANGING JOB and confirmed by depressing [#/TM/ST] (XE-A203V) or [#/ST] (XEA213V) key after a data that want to set at Z2 mode. It is entered. TIME) HH: Hour (00 to 23) MM: Minute (00...
Programming Guide
Page 10
... POWER OFF = 001--254 (minutes) or 999 (Inhibit) [JOB#11] LOGO PRINTING -- B: CONTENTS OF RECEIPT B TOTAL 0 DETAIL 1★ C: TIME PRINTING (for all receipt) PRINT NOT PRINT C 0★ 1 D: DATE PRINTING (for rewinding reports anytime. ABCDEFGH -- MRS = 5 A: LOGO MESSAGE CONTROL A 3-LINE HEADER INSTEAD OF GRAPHIC LOGO 0 GRAPHIC LOGO ONLY 1 GRAPHIC LOGO AND 3-LINE FOOTER 2 6-LINE HEADER 3 GRAPHIC LOGO AND 3-LINE HEADER 4 3-LINE HEADER AND 3-LINE FOOTER 5★ [JOB...
... POWER OFF = 001--254 (minutes) or 999 (Inhibit) [JOB#11] LOGO PRINTING -- B: CONTENTS OF RECEIPT B TOTAL 0 DETAIL 1★ C: TIME PRINTING (for all receipt) PRINT NOT PRINT C 0★ 1 D: DATE PRINTING (for rewinding reports anytime. ABCDEFGH -- MRS = 5 A: LOGO MESSAGE CONTROL A 3-LINE HEADER INSTEAD OF GRAPHIC LOGO 0 GRAPHIC LOGO ONLY 1 GRAPHIC LOGO AND 3-LINE FOOTER 2 6-LINE HEADER 3 GRAPHIC LOGO AND 3-LINE HEADER 4 3-LINE HEADER AND 3-LINE FOOTER 5★ [JOB...
Programming Guide
Page 14
...XE-A203/A213 PROGRAM MODE 2 - 11 XXXX -- XX -- 11) DOMESTIC CURRENCY SYMBOL PROGRAMMING XE-A203V: NO CHANGE #/TM/ST 85 (CHARACTERS) #/TM/ST TL/NS XE-A213V: NO CHANGE... ST 85 (CHARACTERS) ST TL/NS (CHARACTERS): CHARACTER (Max. 4 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. [JOB#69] OTHERS9 PROGRAMMING -- XXXX -- MRS = 10000000 A: VAT SHIFT OPERATION TIMING... (In case of " DM", the number of character is printed with (+) amount of symbol (like " *"), they are programmed at...
...XE-A203/A213 PROGRAM MODE 2 - 11 XXXX -- XX -- 11) DOMESTIC CURRENCY SYMBOL PROGRAMMING XE-A203V: NO CHANGE #/TM/ST 85 (CHARACTERS) #/TM/ST TL/NS XE-A213V: NO CHANGE... ST 85 (CHARACTERS) ST TL/NS (CHARACTERS): CHARACTER (Max. 4 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. [JOB#69] OTHERS9 PROGRAMMING -- XXXX -- MRS = 10000000 A: VAT SHIFT OPERATION TIMING... (In case of " DM", the number of character is printed with (+) amount of symbol (like " *"), they are programmed at...
Programming Guide
Page 15
.../2006 123456#123456 12:34PM 01 M.KLERK *PGM* #90 0 DATE/MACHINE NO./CC-NO. TIME/CLERK NO/CLERK NAME MODE TITLE JOB# XE-A203/A213 PROGRAM MODE 2 - 12 13) TEXT CHANGING (TO DEFAULT TEXT) XE-A203V: #/TM/ST 88 0 X TL/NS XE-A213V: ST 88 0 X TL/NS X: 0 = English text 1 = German text 2 = French...Each message text (LOGO,etc..) (c) Clerk name (Sample) HEADER 05/02/2006 123456#123456 12:34PM 01 M.KLERK *PGM* #88 0 DATE/MACHINE NO./CC-NO. TIME/CLERK NO/CLERK NAME MODE TITLE LANGUAGE MODE 15) CHANGING MEMORY TYPE (EJ RECORD AND PLU RECORD) XE-A203V: #/TM/ST 90 X XE-A213V: ST ...
.../2006 123456#123456 12:34PM 01 M.KLERK *PGM* #90 0 DATE/MACHINE NO./CC-NO. TIME/CLERK NO/CLERK NAME MODE TITLE JOB# XE-A203/A213 PROGRAM MODE 2 - 12 13) TEXT CHANGING (TO DEFAULT TEXT) XE-A203V: #/TM/ST 88 0 X TL/NS XE-A213V: ST 88 0 X TL/NS X: 0 = English text 1 = German text 2 = French...Each message text (LOGO,etc..) (c) Clerk name (Sample) HEADER 05/02/2006 123456#123456 12:34PM 01 M.KLERK *PGM* #88 0 DATE/MACHINE NO./CC-NO. TIME/CLERK NO/CLERK NAME MODE TITLE LANGUAGE MODE 15) CHANGING MEMORY TYPE (EJ RECORD AND PLU RECORD) XE-A203V: #/TM/ST 90 X XE-A213V: ST ...
Programming Guide
Page 19
... to enter each data at each step. To change a programming content, it changes it using a keyboard. As additional way, [00] key can be printed. [PURPOSE] It aims to be used some ...by this method ("Direct key entry type") on the LCD-display every time. d Point key ([.]) Used for left moving entry (as it wants to set up %1...SUB] 4 Type Entry type Default (MRS) (CHARACTER) PLU.xxxx (NUMERIC) 0 (NUMERIC) 01 (TOGGLE) PLU XE-A203/A213 PROGRAM MODE 2 - 16 Direct key or code entry type. 2. EASY PROGRAMMING Easy programming roughly consists of the ...
... to enter each data at each step. To change a programming content, it changes it using a keyboard. As additional way, [00] key can be printed. [PURPOSE] It aims to be used some ...by this method ("Direct key entry type") on the LCD-display every time. d Point key ([.]) Used for left moving entry (as it wants to set up %1...SUB] 4 Type Entry type Default (MRS) (CHARACTER) PLU.xxxx (NUMERIC) 0 (NUMERIC) 01 (TOGGLE) PLU XE-A203/A213 PROGRAM MODE 2 - 16 Direct key or code entry type. 2. EASY PROGRAMMING Easy programming roughly consists of the ...