GS516T Reference Manual
Page 6
APPENDIX A Technical Specifications B-1 APPENDIX B Connector Pin Assignments RJ-45 Plug and RJ-45 Connector B-1 APPENDIX C Cabling Guidelines Using 1000BASE-T Gigabit Ethernet over Category 5 Cable C-1 Overview C-1 Cabling C-1 Length C-1 Return Loss C-2 Near End Cross Talk (NEXT) C-2 Patch Cables C-3 Conclusions C-3 Fast Ethernet Cable guidelines C-3 Category 5 Cable C-4 Category 5 Cable Specifications C-4 Twisted Pair Cables for 1000BASE-TX C-5 Patch Panel and cables C-6 contents vi
APPENDIX A Technical Specifications B-1 APPENDIX B Connector Pin Assignments RJ-45 Plug and RJ-45 Connector B-1 APPENDIX C Cabling Guidelines Using 1000BASE-T Gigabit Ethernet over Category 5 Cable C-1 Overview C-1 Cabling C-1 Length C-1 Return Loss C-2 Near End Cross Talk (NEXT) C-2 Patch Cables C-3 Conclusions C-3 Fast Ethernet Cable guidelines C-3 Category 5 Cable C-4 Category 5 Cable Specifications C-4 Twisted Pair Cables for 1000BASE-TX C-5 Patch Panel and cables C-6 contents vi
GS516T Reference Manual
Page 18
... Gigabit Switch Power Ethernet MODEL GS516T Figure 4-1. Attaching Mounting Brackets Connecting Devices to Figure 4-1 when installing the switch in a Rack Refer to the Switch To connect the switch: 1. Connect one end of the AC power adapter cable to the power receptacle on the rear panel of the switch and ... the bottom of the power adapter cable to the wall outlet. Connect the devices to 100 m. 2. Note: Ethernet specifications limit the cable length between your PC or server and the switch to the network ports on the switch, using Category 5 (Cat5) or Category 5e (Cat5e) UTP cable.
... Gigabit Switch Power Ethernet MODEL GS516T Figure 4-1. Attaching Mounting Brackets Connecting Devices to Figure 4-1 when installing the switch in a Rack Refer to the Switch To connect the switch: 1. Connect one end of the AC power adapter cable to the power receptacle on the rear panel of the switch and ... the bottom of the power adapter cable to the wall outlet. Connect the devices to 100 m. 2. Note: Ethernet specifications limit the cable length between your PC or server and the switch to the network ports on the switch, using Category 5 (Cat5) or Category 5e (Cat5e) UTP cable.
GS516T Reference Manual
Page 20
... are mismatched. COL LED is set to auto negotiate. troubleshooting 5-1 CHAPTER 5: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR Model GS516T Copper Gigabit Switch. Check the power cord connections for a defective adapter card, cable, or port by testing them in half-duplex mode....used are functioning. Make sure all cables used are correct and comply with Ethernet specifications. 1000M or 100M LED is properly inserted and locked into the port at the switch. File transfer is slow or performance degradation is off or intermittent. Verify that ...
... are mismatched. COL LED is set to auto negotiate. troubleshooting 5-1 CHAPTER 5: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR Model GS516T Copper Gigabit Switch. Check the power cord connections for a defective adapter card, cable, or port by testing them in half-duplex mode....used are functioning. Make sure all cables used are correct and comply with Ethernet specifications. 1000M or 100M LED is properly inserted and locked into the port at the switch. File transfer is slow or performance degradation is off or intermittent. Verify that ...
GS516T Reference Manual
Page 22
... SPECIFICATIONS This appendix provides technical specifications for the NETGEAR Model GS516T Copper Gigabit Switch. Network Protocol and Standards Compatibility IEEE 802.3ab 1000BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3i 10BASE-T IEEE 802.3x flow control Data Coding 1000 Mbps with PAM5 encoding 100 Mbps with MLT3 encoding 10 Mbps with Manchester encoding Performance Specifications...,800 frames/second maximum(10 Mbps) 30 microseconds maximum Address database size: 8,000 MAC addresses Addressing: 48-bit MAC address Forwording Mode: store & Forward technical specifications A-1
... SPECIFICATIONS This appendix provides technical specifications for the NETGEAR Model GS516T Copper Gigabit Switch. Network Protocol and Standards Compatibility IEEE 802.3ab 1000BASE-T IEEE 802.3u 100BASE-TX IEEE 802.3i 10BASE-T IEEE 802.3x flow control Data Coding 1000 Mbps with PAM5 encoding 100 Mbps with MLT3 encoding 10 Mbps with Manchester encoding Performance Specifications...,800 frames/second maximum(10 Mbps) 30 microseconds maximum Address database size: 8,000 MAC addresses Addressing: 48-bit MAC address Forwording Mode: store & Forward technical specifications A-1
GS516T Reference Manual
Page 23
... Ethernet, 100BASE-TX Fast Ethernet, and 1000BASE-T Gigabit Ethernet Power Consumption 75 W Input Voltage (Power Adapter) 100-240 V AC Physical Specifications Dimensions: 13.0 x 1.7 x 8.0 in.; 33.0 x 4.3 x 20.7 cm Weight: 5.3 lb; 2.3 kg Environmental Specifications Operating Temperature: 0 to 40º C (32 to 104º F) Operating Humidity: 90% maximum relative humidity, noncondensing Heat Radiation:...noncondensing Electromagnetic Compliance CE mark, commercial FCC Part 15 Class A VCCI Class A EN 55022 (CISPR 22) Class A EN 50082-1 EN 55024 C-Tick technical specifications A-2
... Ethernet, 100BASE-TX Fast Ethernet, and 1000BASE-T Gigabit Ethernet Power Consumption 75 W Input Voltage (Power Adapter) 100-240 V AC Physical Specifications Dimensions: 13.0 x 1.7 x 8.0 in.; 33.0 x 4.3 x 20.7 cm Weight: 5.3 lb; 2.3 kg Environmental Specifications Operating Temperature: 0 to 40º C (32 to 104º F) Operating Humidity: 90% maximum relative humidity, noncondensing Heat Radiation:...noncondensing Electromagnetic Compliance CE mark, commercial FCC Part 15 Class A VCCI Class A EN 55022 (CISPR 22) Class A EN 50082-1 EN 55024 C-Tick technical specifications A-2
GS516T Reference Manual
Page 24
Safety Agency Approvals UL Listed (UL 1950), cUL TUV Licensed (EN 60 950) technical specifications A-3
Safety Agency Approvals UL Listed (UL 1950), cUL TUV Licensed (EN 60 950) technical specifications A-3
GS516T Reference Manual
Page 27
...multiple pairs on horizontal runs and punch down blocks. APPENDIX C: CABLING GUIDELINES This appendix provides specifications for 1000BASE-T. Cabling The 1000BASE-T product is designed to operate over Category 5 Cable Overview ... components in your cabling system are designed to act as per the original Ethernet specification.The end to have been amended.The latest standard is Category 5e, which is...it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. cabling guidelines C-1 TSB-67 defines the "Basic Link" which defines a higher level of the...
...multiple pairs on horizontal runs and punch down blocks. APPENDIX C: CABLING GUIDELINES This appendix provides specifications for 1000BASE-T. Cabling The 1000BASE-T product is designed to operate over Category 5 Cable Overview ... components in your cabling system are designed to act as per the original Ethernet specification.The end to have been amended.The latest standard is Category 5e, which is...it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. cabling guidelines C-1 TSB-67 defines the "Basic Link" which defines a higher level of the...
GS516T Reference Manual
Page 29
... Conclusions For optimum performance of your 1000BASE-T product, it meets or exceeds ANSI/EIA/TIA568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Category 5 cable is important to fully qualify your cable installation and ensure it is certified up to the point of cable is critical... removal, and untwist lengths. When installing Category 5 UTP cabling, use the following guidelines to ensure that your cables perform to the following specifications: • Certification Make sure that do not meet the requirements in ANSI/EIA/TIA-568A-3. As pointed out in a single plastic sheath...
... Conclusions For optimum performance of your 1000BASE-T product, it meets or exceeds ANSI/EIA/TIA568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Category 5 cable is important to fully qualify your cable installation and ensure it is certified up to the point of cable is critical... removal, and untwist lengths. When installing Category 5 UTP cabling, use the following guidelines to ensure that your cables perform to the following specifications: • Certification Make sure that do not meet the requirements in ANSI/EIA/TIA-568A-3. As pointed out in a single plastic sheath...
GS516T Reference Manual
Page 30
Category 5 Cable Specifications Table C-1 lists the electrical requirements of untwist in length, divided as follows: • 20 ft (6 m) between the hub or switch and the patch panel (if used) • 295 ft (90 m) from the wiring closet to the wall outlet • 10 ft (3... feet (ft) or 100 meters (m) in the wire pair is allowed at 100 MHz: 32 cabling guidelines C-4 Table C-1. Electrical Requirements of Category 5 Cable Specification Category 5 Cable Requirements Number of pairs Impedance Mutual capacitance at 1 KHz Four 100 Ω ± 15% ≤ 5.6 nF per 100 m Maximum ...
Category 5 Cable Specifications Table C-1 lists the electrical requirements of untwist in length, divided as follows: • 20 ft (6 m) between the hub or switch and the patch panel (if used) • 295 ft (90 m) from the wiring closet to the wall outlet • 10 ft (3... feet (ft) or 100 meters (m) in the wire pair is allowed at 100 MHz: 32 cabling guidelines C-4 Table C-1. Electrical Requirements of Category 5 Cable Specification Category 5 Cable Requirements Number of pairs Impedance Mutual capacitance at 1 KHz Four 100 Ω ± 15% ≤ 5.6 nF per 100 m Maximum ...