GS108T/ GS110TP Smart Switch Software Administration Manual
Page 13
GS108T and GS110TP Smart Switch Software Administration Manual 6. Chapter 1: Getting Started | 13 The default password is password. Use your Web browser to access the switch directly from a Web browser (without using the Smart Control Center). 7. Make a note of the switch covered in Using the Web Interface on page 24. The Smart Control Center displays a login window similar to management...
GS108T and GS110TP Smart Switch Software Administration Manual 6. Chapter 1: Getting Started | 13 The default password is password. Use your Web browser to access the switch directly from a Web browser (without using the Smart Control Center). 7. Make a note of the switch covered in Using the Web Interface on page 24. The Smart Control Center displays a login window similar to management...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 17
... to ping the IP address of the following figure. Login Screen Chapter 1: Getting Started | 17 Clicking Web Browser Access on the Smart Control Center or accessing the switch directly from your Web browser. GS108T and GS110TP Smart Switch Software Administration Manual Web Access To access the GS108T or GS110TP management interface, use that IP address in the...
... to ping the IP address of the following figure. Login Screen Chapter 1: Getting Started | 17 Clicking Web Browser Access on the Smart Control Center or accessing the switch directly from your Web browser. GS108T and GS110TP Smart Switch Software Administration Manual Web Access To access the GS108T or GS110TP management interface, use that IP address in the...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 24
..., as shown in the Web browser address field. 2. Figure 3 on page 17, and then click Login. GS108T and GS110TP Smart Switch Software Administration Manual Understanding the User Interfaces The switch software includes a set of comprehensive management functions for configuring and monitoring the system by using one of the following procedures to log on your network...
..., as shown in the Web browser address field. 2. Figure 3 on page 17, and then click Login. GS108T and GS110TP Smart Switch Software Administration Manual Understanding the User Interfaces The switch software includes a set of comprehensive management functions for configuring and monitoring the system by using one of the following procedures to log on your network...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 29
...additional switch functionality. GS108T and GS110TP Smart Switch Software Administration Manual Using SNMP The switch software supports the configuration of eight or more alphanumeric characters in -SWITCHING-MIB,... which is a private MIB. Click Apply. Some interface configurations also involve objects in the Encryption Protocol field. The System Management System Information Web page, which is the page that the SNMP agent generates. Chapter 1: Getting Started | 29 Any user can manage traps that displays after a successful login...
...additional switch functionality. GS108T and GS110TP Smart Switch Software Administration Manual Using SNMP The switch software supports the configuration of eight or more alphanumeric characters in -SWITCHING-MIB,... which is a private MIB. Click Apply. Some interface configurations also involve objects in the Encryption Protocol field. The System Management System Information Web page, which is the page that the SNMP agent generates. Chapter 1: Getting Started | 29 Any user can manage traps that displays after a successful login...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 33
...of Service on page 42 • DNS on page 44 • Green Ethernet Configuration on page 47 System Information After a successful login, the System Information page displays. Chapter 2: Configuring System Information | 33 From the Management link, you want to use up to...view general device information. Use this switch. You may use to display the switch status and specify some basic switch information, such as the management interface IP address, system clock settings, and DNS information. GS108T and GS110TP Smart Switch Software Administration Manual Management This section describes...
...of Service on page 42 • DNS on page 44 • Green Ethernet Configuration on page 47 System Information After a successful login, the System Information page displays. Chapter 2: Configuring System Information | 33 From the Management link, you want to use up to...view general device information. Use this switch. You may use to display the switch status and specify some basic switch information, such as the management interface IP address, system clock settings, and DNS information. GS108T and GS110TP Smart Switch Software Administration Manual Management This section describes...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 58
...eight characters in the Encryption Protocol field, enter the SNMPv3 Encryption Key here. Configuration changes take effect immediately. 5. GS108T and GS110TP Smart Switch Software Administration Manual SNMP v3 User Configuration This is the configuration for the user account. To access this field is ignored. ...switch. 58 | Chapter 2: Configuring System Information Encrypt SNMPv3 packets using the DES encryption protocol. 3. If you select: • None: The user will be unable to the latest value of SNMPv3 packets transmitted from an SNMP browser. • MD5 or SHA: The user login...
...eight characters in the Encryption Protocol field, enter the SNMPv3 Encryption Key here. Configuration changes take effect immediately. 5. GS108T and GS110TP Smart Switch Software Administration Manual SNMP v3 User Configuration This is the configuration for the user account. To access this field is ignored. ...switch. 58 | Chapter 2: Configuring System Information Encrypt SNMPv3 packets using the DES encryption protocol. 3. If you select: • None: The user will be unable to the latest value of SNMPv3 packets transmitted from an SNMP browser. • MD5 or SHA: The user login...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 146
... 147 • Configuring TACACS+ on page 153 • Authentication List Configuration on the screen to make sure you can configure the login password, Remote Authorization Dial-In User Service (RADIUS) settings, Terminal Access Controller Access Control System (TACACS+) settings, and authentication lists...screen and reset the data on page 155 Change Password Use the page to the default value. 5. GS108T and GS110TP Smart Switch Software Administration Manual Management Security Settings From the Management Security Settings page, you entered it is typed, and only asterisks (*) will show...
... 147 • Configuring TACACS+ on page 153 • Authentication List Configuration on the screen to make sure you can configure the login password, Remote Authorization Dial-In User Service (RADIUS) settings, Terminal Access Controller Access Control System (TACACS+) settings, and authentication lists...screen and reset the data on page 155 Change Password Use the page to the default value. 5. GS108T and GS110TP Smart Switch Software Administration Manual Management Security Settings From the Management Security Settings page, you entered it is typed, and only asterisks (*) will show...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 148
... on each will not occur until the RADIUS application returns a response. 3. If the RADIUS request was generated by a user login attempt, all user interfaces will be exhausted before the next server is attempted. If multiple RADIUS servers are configured (see RADIUS Server... should be blocked until the configured timeout value on that server has passed without a response from the RADIUS server. GS108T and GS110TP Smart Switch Software Administration Manual The Current Server IP Address field is enabled or disabled on the current server. 4. If the RADIUS request...
... on each will not occur until the RADIUS application returns a response. 3. If the RADIUS request was generated by a user login attempt, all user interfaces will be exhausted before the next server is attempted. If multiple RADIUS servers are configured (see RADIUS Server... should be blocked until the configured timeout value on that server has passed without a response from the RADIUS server. GS108T and GS110TP Smart Switch Software Administration Manual The Current Server IP Address field is enabled or disabled on the current server. 4. If the RADIUS request...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 153
... user names and user-defined passwords. • Authorization: Performed at login. The TACACS+ folder contains links to establish a TCP connection between the device and TACACS+ server. GS108T and GS110TP Smart Switch Software Administration Manual Configuring TACACS+ TACACS+ provides a centralized user management ... authenticated user name. In the Key String field, specify the authentication and encryption key for communication between the GS108T or GS110TP and the TACACS+ server. Chapter 5: Managing Device Security | 153 To configure global TACACS+ settings: 1. In the ...
... user names and user-defined passwords. • Authorization: Performed at login. The TACACS+ folder contains links to establish a TCP connection between the device and TACACS+ server. GS108T and GS110TP Smart Switch Software Administration Manual Configuring TACACS+ TACACS+ provides a centralized user management ... authenticated user name. In the Key String field, specify the authentication and encryption key for communication between the GS108T or GS110TP and the TACACS+ server. Chapter 5: Managing Device Security | 153 To configure global TACACS+ settings: 1. In the ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 155
...field, specify the amount of time that passes before the connection between the GS108T or GS110TP and the TACACS+ server. The field range is the highest priority. 3. A login list specifies one or more authentication methods to the defaultList name Chapter 5: Managing Device ...If you cannot delete. In the Key String field, specify the authentication and encryption key for the defaultList: 1. GS108T and GS110TP Smart Switch Software Administration Manual 2. To change the authentication method for TACACS+ communications between the device and the TACACS+ server times out....
...field, specify the amount of time that passes before the connection between the GS108T or GS110TP and the TACACS+ server. The field range is the highest priority. 3. A login list specifies one or more authentication methods to the defaultList name Chapter 5: Managing Device ...If you cannot delete. In the Key String field, specify the authentication and encryption key for the defaultList: 1. GS108T and GS110TP Smart Switch Software Administration Manual 2. To change the authentication method for TACACS+ communications between the device and the TACACS+ server times out....
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 156
...that should appear first in the selected authentication login list. Use the drop down menu in the 3 column to select the authentication method that will be used for Method 2 and Method 3. 3. GS108T and GS110TP Smart Switch Software Administration Manual 2. Possible methods are selected.... If you first create a new login list. 5. Use the menu in the 1 column to select the authentication method, if ...
...that should appear first in the selected authentication login list. Use the drop down menu in the 3 column to select the authentication method that will be used for Method 2 and Method 3. 3. GS108T and GS110TP Smart Switch Software Administration Manual 2. Possible methods are selected.... If you first create a new login list. 5. Use the menu in the 1 column to select the authentication method, if ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 220
... management interface is not available until the switch completes the boot cycle. To reboot the switch: 1. To access the Device Reboot page, click Maintenance Reset Device Reboot. Click Apply. After the switch resets, the login screen appears. 220 | Chapter 7: Maintaining the System GS108T and GS110TP Smart Switch Software Administration Manual Reset The Reset menu contains...
... management interface is not available until the switch completes the boot cycle. To reboot the switch: 1. To access the Device Reboot page, click Maintenance Reset Device Reboot. Click Apply. After the switch resets, the login screen appears. 220 | Chapter 7: Maintaining the System GS108T and GS110TP Smart Switch Software Administration Manual Reset The Reset menu contains...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 267
See PSE PSE 12, 14 Index | 267 GS108T and GS110TP Smart Switch Software Administration Manual E EAP 206 EAPOL 207 F file management 228 firmware 21 firmware download 223 G Green...querier 117 interface LAG 79 logical 30 naming convention 30 physical 30 queue configuration 129 IP address administrative system 15 switch 11, 34 IP DSCP 126 Mapping 131 L LACP port configuration 83 LAG VLAN 79 LAGPDUs 79 LAGs 79 ...37 MIBs 29 multicast, layer 2 109 N navigation 25 O OUI 91 P password change 18, 146 login 146 Ping 231 PoE 12, 14, 48 port authentication 164 summary 169 Power Sourcing Equipment.
See PSE PSE 12, 14 Index | 267 GS108T and GS110TP Smart Switch Software Administration Manual E EAP 206 EAPOL 207 F file management 228 firmware 21 firmware download 223 G Green...querier 117 interface LAG 79 logical 30 naming convention 30 physical 30 queue configuration 129 IP address administrative system 15 switch 11, 34 IP DSCP 126 Mapping 131 L LACP port configuration 83 LAG VLAN 79 LAGPDUs 79 LAGs 79 ...37 MIBs 29 multicast, layer 2 109 N navigation 25 O OUI 91 P password change 18, 146 login 146 Ping 231 PoE 12, 14, 48 port authentication 164 summary 169 Power Sourcing Equipment.
GS108Tv2/GS110TP Software Reference Manual
Page 18
... Web Interface" on page 1-15. 1-4 Getting Started v1.0, April 2010 The Smart Control Center displays a login window similar to manage your Web browser to Figure 1-3. You will need this page to proceed to access the switch directly from a Web browser (without using the Smart Control Center). GS108T and GS110TP Smart Switch Software Administration Manual 6. Figure 1-3 Use your...
... Web Interface" on page 1-15. 1-4 Getting Started v1.0, April 2010 The Smart Control Center displays a login window similar to manage your Web browser to Figure 1-3. You will need this page to proceed to access the switch directly from a Web browser (without using the Smart Control Center). GS108T and GS110TP Smart Switch Software Administration Manual 6. Figure 1-3 Use your...
GS108Tv2/GS110TP Software Reference Manual
Page 22
...You must be available. If you did not change the IP address of the switch from your Web browser displays the login screen in the address field. After you change the network settings on the switch, return the network configuration on page 1-9. 1-8 Getting Started v1.0, April 2010 Clicking...Web Browser Access. • Open a Web browser and enter the IP address of the switch in Figure 1-6 on your administrative system to the rest of the network. GS108T and GS110TP Smart Switch Software Administration Manual Warning: When you change the IP address of your administrative system, you ...
...You must be available. If you did not change the IP address of the switch from your Web browser displays the login screen in the address field. After you change the network settings on the switch, return the network configuration on page 1-9. 1-8 Getting Started v1.0, April 2010 Clicking...Web Browser Access. • Open a Web browser and enter the IP address of the switch in Figure 1-6 on your administrative system to the rest of the network. GS108T and GS110TP Smart Switch Software Administration Manual Warning: When you change the IP address of your administrative system, you ...
GS108Tv2/GS110TP Software Reference Manual
Page 29
... management functions for configuring and monitoring the system by using one of the GS108T and GS110TP software. Open a Web browser and enter the IP address of the switch in Figure 1-6 on page 1-9, and then click Login. The GS108T and GS110TP Smart Switch Software Administration Manual describes how to use to the Web interface: 1. Type the password...
... management functions for configuring and monitoring the system by using one of the GS108T and GS110TP software. Open a Web browser and enter the IP address of the switch in Figure 1-6 on page 1-9, and then click Login. The GS108T and GS110TP Smart Switch Software Administration Manual describes how to use to the Web interface: 1. Type the password...
GS108Tv2/GS110TP Software Reference Manual
Page 34
... Configuration page. 2. To configure authentication and encryption settings for the SNMPv3 admin profile by default. GS108T and GS110TP Smart Switch Software Administration Manual Help Page Access Every page contains a link to the online help , which is a ...GS110TP switches use both standard public MIBs for authentication and encryption, the switch supports only one profile that can manage traps that support additional switch functionality. Some interface configurations also involve objects in configuring and managing the switch. SNMP is the page that displays after a successful login...
... Configuration page. 2. To configure authentication and encryption settings for the SNMPv3 admin profile by default. GS108T and GS110TP Smart Switch Software Administration Manual Help Page Access Every page contains a link to the online help , which is a ...GS110TP switches use both standard public MIBs for authentication and encryption, the switch supports only one profile that can manage traps that support additional switch functionality. Some interface configurations also involve objects in configuring and managing the switch. SNMP is the page that displays after a successful login...
GS108Tv2/GS110TP Software Reference Manual
Page 37
Use this page to display the switch status and specify some basic switch information, such as the management interface IP address, system clock settings, and DNS information. DHCP Filtering" on page 2-45 Management This section describes how ...System Information page, click System Management System Information. Chapter 2 Configuring System Information Use the features in the System tab to define the switch's relationship to the following displays. 2-1 v1.0, April 2010 The System tab contains links to the following features: • "Management" on page 2-1 • "...
Use this page to display the switch status and specify some basic switch information, such as the management interface IP address, system clock settings, and DNS information. DHCP Filtering" on page 2-45 Management This section describes how ...System Information page, click System Management System Information. Chapter 2 Configuring System Information Use the features in the System tab to define the switch's relationship to the following displays. 2-1 v1.0, April 2010 The System tab contains links to the following features: • "Management" on page 2-1 • "...
GS108Tv2/GS110TP Software Reference Manual
Page 66
... are 0 to 15 characters long. 4. Click Apply to send the updated configuration to encrypt SNMPv3 packets transmitted by the switch. • None. GS108T and GS110TP Smart Switch Software Administration Manual Figure 2-17 The SNMPv3 Access Mode is ignored. To configure SNMPv3 settings for the user account: 1. ...The user will be unable to the latest value of SNMPv3 packets transmitted from an SNMP browser. • MD5 or SHA: The user login password will be eight characters in the Encryption Protocol field, enter the SNMPv3 Encryption Key here. Otherwise, this field is a read-only...
... are 0 to 15 characters long. 4. Click Apply to send the updated configuration to encrypt SNMPv3 packets transmitted by the switch. • None. GS108T and GS110TP Smart Switch Software Administration Manual Figure 2-17 The SNMPv3 Access Mode is ignored. To configure SNMPv3 settings for the user account: 1. ...The user will be unable to the latest value of SNMPv3 packets transmitted from an SNMP browser. • MD5 or SHA: The user login password will be eight characters in the Encryption Protocol field, enter the SNMPv3 Encryption Key here. Otherwise, this field is a read-only...
GS108Tv2/GS110TP Software Reference Manual
Page 169
...; "Configuring TACACS+" on page 5-10 • "Authentication List Configuration" on page 5-42 Management Security Settings From the Management Security Settings page, you can configure the login password, Remote Authorization Dial-In User Service (RADIUS) settings, Terminal Access Controller Access Control System (TACACS+) settings, and authentication lists. Chapter 5 Managing Device Security Use...
...; "Configuring TACACS+" on page 5-10 • "Authentication List Configuration" on page 5-42 Management Security Settings From the Management Security Settings page, you can configure the login password, Remote Authorization Dial-In User Service (RADIUS) settings, Terminal Access Controller Access Control System (TACACS+) settings, and authentication lists. Chapter 5 Managing Device Security Use...