FSM7328PS Command line reference manual
Page 273
...Discovery command is not available on the FSM7328S abd FSM7352S switches. 14.3.1 ip irdp This command enables Router Discovery on an interface. The Router Discovery Protocol enables a host to RFC 1213 for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.2.23 show ip stats Modes Privileged EXEC User...Interface Config Routing Commands v3.0, January 2008 14-19 Refer to discover the IP address of routers on the switch. Format no ip irdp This command disables Router Discovery on an interface. Format show ip stats This command displays IP statistical ...
...Discovery command is not available on the FSM7328S abd FSM7352S switches. 14.3.1 ip irdp This command enables Router Discovery on an interface. The Router Discovery Protocol enables a host to RFC 1213 for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.2.23 show ip stats Modes Privileged EXEC User...Interface Config Routing Commands v3.0, January 2008 14-19 Refer to discover the IP address of routers on the switch. Format no ip irdp This command disables Router Discovery on an interface. Format show ip stats This command displays IP statistical ...
FSM7328PS Command line reference manual
Page 278
.... It will be displayed above the perVLAN information. Subnet Mask Indicates the subnet mask that is not available on the FSM7328S and FSM7352S switches. 14-24 v3.0, January 2008 Routing Commands VRRP helps provide failover and load balancing when you use to view and configure VRRP ...and to view VRRP status information. Format show ip vlan This command displays the VLAN routing information for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.4.2 show ip vlan Modes Privileged EXEC User EXEC MAC Address used by Routing VLANs Is the MAC Address associated...
.... It will be displayed above the perVLAN information. Subnet Mask Indicates the subnet mask that is not available on the FSM7328S and FSM7352S switches. 14-24 v3.0, January 2008 Routing Commands VRRP helps provide failover and load balancing when you use to view and configure VRRP ...and to view VRRP status information. Format show ip vlan This command displays the VLAN routing information for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.4.2 show ip vlan Modes Privileged EXEC User EXEC MAC Address used by Routing VLANs Is the MAC Address associated...
FSM7328PS Command line reference manual
Page 285
... use to view and configure OSPF, which is not available on the FSM7328S and FSM7352S switches. State Represents the state (Master/backup) of a virtual router configured on a specific interface. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.5.12 show ip vrrp interface Modes Privileged EXEC User EXEC IP Address...
... use to view and configure OSPF, which is not available on the FSM7328S and FSM7352S switches. State Represents the state (Master/backup) of a virtual router configured on a specific interface. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 14.5.12 show ip vrrp interface Modes Privileged EXEC User EXEC IP Address...
FSM7352S Hardware manual
Page 1
Model FSM7328S, FSM7352S, and FSM7352PS Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 201-10802-01 March 2006
Model FSM7328S, FSM7352S, and FSM7352PS Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 201-10802-01 March 2006
FSM7352S Hardware manual
Page 2
... © 2006 by Information Technology Equipment (VCCI). Trademarks The Netgear Logo, the Gear Guy, Everybody's connecting, and ProSafe are trademarks or registered trademarks of the Voluntary Control Council for ...compliance with the regulations may , however, be required to test the series for Interference by NETGEAR, Inc. in the operating instructions. NETGEAR does not assume any interference received, including interference that the NETGEAR Model FSM7352S Managed Fast Ethernet Switch...
... © 2006 by Information Technology Equipment (VCCI). Trademarks The Netgear Logo, the Gear Guy, Everybody's connecting, and ProSafe are trademarks or registered trademarks of the Voluntary Control Council for ...compliance with the regulations may , however, be required to test the series for Interference by NETGEAR, Inc. in the operating instructions. NETGEAR does not assume any interference received, including interference that the NETGEAR Model FSM7352S Managed Fast Ethernet Switch...
FSM7352S Hardware manual
Page 3
... the instructions, may cause harmful interference to radio communications. World Wide Web NETGEAR maintains a World Wide Web home page that which can access at the universal resource locator (URL) http://www.netgear.com. However, there is encouraged to try to correct the interference by...to comply with the limits for help. Publication Version 1.0, March 2006 Cet appareil numérique (ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites...
... the instructions, may cause harmful interference to radio communications. World Wide Web NETGEAR maintains a World Wide Web home page that which can access at the universal resource locator (URL) http://www.netgear.com. However, there is encouraged to try to correct the interference by...to comply with the limits for help. Publication Version 1.0, March 2006 Cet appareil numérique (ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites...
FSM7352S Hardware manual
Page 5
... 2 Introduction FSM7328S Front Panel and LEDs 2-1 FSM7328S Rear Panel 2-3 FSM7352S Front Panel and LEDs 2-3 FSM7352S Rear Panel 2-4 FSM7352PS Front Panel and LEDs 2-5 FSM7352PS Rear Panel ...2-7 Safety Instructions ...2-7 Chapter 3 Hardware Installation Package Contents ...3-1 Protecting Against Electrostatic Discharge 3-2 Unpacking the Hardware 3-2 Installation ...3-4 Select a Location ...3-4 Install the Switch ...3-5 Check the Installation 3-6 Connect to Power and Check the LEDs 3-7 Stacking Switches...
... 2 Introduction FSM7328S Front Panel and LEDs 2-1 FSM7328S Rear Panel 2-3 FSM7352S Front Panel and LEDs 2-3 FSM7352S Rear Panel 2-4 FSM7352PS Front Panel and LEDs 2-5 FSM7352PS Rear Panel ...2-7 Safety Instructions ...2-7 Chapter 3 Hardware Installation Package Contents ...3-1 Protecting Against Electrostatic Discharge 3-2 Unpacking the Hardware 3-2 Installation ...3-4 Select a Location ...3-4 Install the Switch ...3-5 Check the Installation 3-6 Connect to Power and Check the LEDs 3-7 Stacking Switches...
FSM7352S Hardware manual
Page 7
...uses the following formats to highlight special messages: Note: This format is used to highlight information of the NETGEAR® FSM7328S, FSM7352S, and FSM7352PS switches. Tip: This format is intended for set up and management of importance or special interest. Chapter 1 ...About This Manual The FSM7328S, FSM7352S, and FSM7352PS Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide contains information for network managers familiar with network management concepts and terminology. Audience, ...
...uses the following formats to highlight special messages: Note: This format is used to highlight information of the NETGEAR® FSM7328S, FSM7352S, and FSM7352PS switches. Tip: This format is intended for set up and management of importance or special interest. Chapter 1 ...About This Manual The FSM7328S, FSM7352S, and FSM7352PS Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide contains information for network managers familiar with network management concepts and terminology. Audience, ...
FSM7352S Hardware manual
Page 8
...-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7328PS • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports and PoE FSM7352PS March 2006 Note: Product updates are available on the NETGEAR, Inc. Failure to take heed of...
...-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7328PS • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports and PoE FSM7352PS March 2006 Note: Product updates are available on the NETGEAR, Inc. Failure to take heed of...
FSM7352S Hardware manual
Page 9
... Front Panel and LEDs The following NETGEAR switches: • ProSafe 24-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7328PS • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports and PoE FSM7352PS These switches can use to eliminate bottlenecks, boost...
... Front Panel and LEDs The following NETGEAR switches: • ProSafe 24-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7328PS • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports FSM7352S • ProSafe 48-Port 10/100 LE managed Stackable Switch with 4 Gigabit Ports and PoE FSM7352PS These switches can use to eliminate bottlenecks, boost...
FSM7352S Hardware manual
Page 11
...bays Stacking ports The following figure shows the front panel of the FSM7352S. Off: The switch is the master of a stack. Introduction 2-3 v1.0, March 2006 Table 2-2. FSM7352S LED Description LED Master Fan Description Green on: The switch is not part of the stack. Solid red: Fan has failed... for the supplied power cord. Power receptacle power Figure 2-2 FSM7352S Front Panel and LEDs The following table shows the FSM7352S LEDs on : The switch is present and operating normally. Off: Fan is not the master of the switch. The front panel contains LEDs, RJ-45 jacks, SFP module...
...bays Stacking ports The following figure shows the front panel of the FSM7352S. Off: The switch is the master of a stack. Introduction 2-3 v1.0, March 2006 Table 2-2. FSM7352S LED Description LED Master Fan Description Green on: The switch is not part of the stack. Solid red: Fan has failed... for the supplied power cord. Power receptacle power Figure 2-2 FSM7352S Front Panel and LEDs The following table shows the FSM7352S LEDs on : The switch is present and operating normally. Off: Fan is not the master of the switch. The front panel contains LEDs, RJ-45 jacks, SFP module...
FSM7352S Hardware manual
Page 12
... Panel The rear panel has a console port and a standard AC power receptacle for the supplied power cord. FSM7352S LED Description (continued) Power Solid green: Power is supplied, and the switch is sending or receiving packets at 10/100 Mbps. Stack LED • Green: Stack port has a valid link connection. • Off: Stack... packets in progress. Solid yellow: Power-On Self-Test (POST) in link up status. • Off: No link is detected. Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide Table 2-2. Blinking green: Runtime code load in progress.
... Panel The rear panel has a console port and a standard AC power receptacle for the supplied power cord. FSM7352S LED Description (continued) Power Solid green: Power is supplied, and the switch is sending or receiving packets at 10/100 Mbps. Stack LED • Green: Stack port has a valid link connection. • Off: Stack... packets in progress. Solid yellow: Power-On Self-Test (POST) in link up status. • Off: No link is detected. Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide Table 2-2. Blinking green: Runtime code load in progress.
FSM7352S Hardware manual
Page 13
... Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide FSM7352PS Front Panel and LEDs The following table describes the FSM7352PS LEDs on the front of PoE power available for another device. Table 2-3. FSM7352S LED Description LED Description ID This is disconnected. Off: ...Fan is operating normally. Power Solid green: Power is supplied, and the switch is present and operating normally.
... Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide FSM7352PS Front Panel and LEDs The following table describes the FSM7352PS LEDs on the front of PoE power available for another device. Table 2-3. FSM7352S LED Description LED Description ID This is disconnected. Off: ...Fan is operating normally. Power Solid green: Power is supplied, and the switch is present and operating normally.
FSM7352S Hardware manual
Page 14
Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide Table 2-3. FSM7352S LED Description (continued) 10/100M Ports One LED per port Copper Link, and Activity LED ... LED • Green: The stack partner successfully established the link. • Blinking green: The switch detects an active link, but the stack partner failed to establish the link. • Off: No link, or the... switch is in stopping power to the port: • Short circuit on PoE power circuit. • PoE ...
Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide Table 2-3. FSM7352S LED Description (continued) 10/100M Ports One LED per port Copper Link, and Activity LED ... LED • Green: The stack partner successfully established the link. • Blinking green: The switch detects an active link, but the stack partner failed to establish the link. • Off: No link, or the... switch is in stopping power to the port: • Short circuit on PoE power circuit. • PoE ...
FSM7352S Hardware manual
Page 19
... • Null-modem serial cable (RS-232) with 9-pin connectors • NETGEAR CD: The CD contains - Documentation including the Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, the Administration Manual for the Managed Stackable Layer 3 Fast Ethernet Switch models FSM7328S, FSM7352S, and FSM7352PS. Package Contents Each switch is packed and shipped separately.
... • Null-modem serial cable (RS-232) with 9-pin connectors • NETGEAR CD: The CD contains - Documentation including the Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, the Administration Manual for the Managed Stackable Layer 3 Fast Ethernet Switch models FSM7328S, FSM7352S, and FSM7352PS. Package Contents Each switch is packed and shipped separately.
FSM7352S Hardware manual
Page 25
... ports, as shown: The number of RJ-45 ports depends on the right side of each switch are preconfigured for the ProSafe 7300S Series Layer-3 Stackable Switches on the NETGEAR CD that shipped with non-stacking interfaces, but the stacking ports are ports 27 and 28 for... Stackable Layer 3 Fast Ethernet Switches Stacking Switches Up to eight switches can connect and establish a link with your product. This single console connection enables you to the master switch. Hardware Installation Guide for the FSM7352S and FSM7352PS. These are always on the switch model, but no traffic will...
... ports, as shown: The number of RJ-45 ports depends on the right side of each switch are preconfigured for the ProSafe 7300S Series Layer-3 Stackable Switches on the NETGEAR CD that shipped with non-stacking interfaces, but the stacking ports are ports 27 and 28 for... Stackable Layer 3 Fast Ethernet Switches Stacking Switches Up to eight switches can connect and establish a link with your product. This single console connection enables you to the master switch. Hardware Installation Guide for the FSM7352S and FSM7352PS. These are always on the switch model, but no traffic will...
FSM7352S Hardware manual
Page 33
... for SFP modules • RS-232 console port Performance • Forwarding modes: store- • Forwarding modes: store- • Forwarding modes: store- Technical Specifications Feature FSM7328S FSM7352S FSM7352PS IEEE Network Protocol and Standards compatibility • 802.3 10BASE-T • 802.3u 100BASE-TX • 802.3z 1000BASE-SX • 802.3ab 1000BASE-T •...-45 connectors for 10BASE-T and 100BASE-TX • 4 RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T • 4 Gigabit Interface Converter (SFP) slots for the switches. Table A-1.
... for SFP modules • RS-232 console port Performance • Forwarding modes: store- • Forwarding modes: store- • Forwarding modes: store- Technical Specifications Feature FSM7328S FSM7352S FSM7352PS IEEE Network Protocol and Standards compatibility • 802.3 10BASE-T • 802.3u 100BASE-TX • 802.3z 1000BASE-SX • 802.3ab 1000BASE-T •...-45 connectors for 10BASE-T and 100BASE-TX • 4 RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T • 4 Gigabit Interface Converter (SFP) slots for the switches. Table A-1.
FSM7352S Hardware manual
Page 34
...100 Mbps ports based on IEE 802.3af standard • IEEE 802.3af power budget: Full power for Managed Stackable Layer 3 Fast Ethernet Switches Table A-1. Technical Specifications (continued) Feature Ports (Auto Uplink and auto-sensing) Addressing 10/100/1000 buffer memory Acoustic noise (ANSI-S10.12...) Heat dissipation Mean time between failure (MTBF) Power consumption Dimensions (W x D x H) FSM7328S FSM7352S FSM7352PS • 24 10/100 Mbps ports • 4 10/100/100 Mbps Fast Ethernet TP ports • 4 gigabit ports to stack up to...
...100 Mbps ports based on IEE 802.3af standard • IEEE 802.3af power budget: Full power for Managed Stackable Layer 3 Fast Ethernet Switches Table A-1. Technical Specifications (continued) Feature Ports (Auto Uplink and auto-sensing) Addressing 10/100/1000 buffer memory Acoustic noise (ANSI-S10.12...) Heat dissipation Mean time between failure (MTBF) Power consumption Dimensions (W x D x H) FSM7328S FSM7352S FSM7352PS • 24 10/100 Mbps ports • 4 10/100/100 Mbps Fast Ethernet TP ports • 4 gigabit ports to stack up to...
FSM7352S Hardware manual
Page 35
Technical Specifications (continued) Feature Environment Electromagnetic emissions and immunity Safety FSM7328S FSM7352S FSM7352PS Temperature • Operating: 32° to 104°F (0° to 40°C) • Storage: -4° to 158°F (-20° to 70°C) Humidity ... certified (CSA 22.2 #950) UL listed (UL 1950)/cUL IEC950/EN60950 Technical Specifications A-3 v1.0, March 2006 Hardware Installation Guide for Managed Stackable Layer 3 Fast Ethernet Switches Table A-1.
Technical Specifications (continued) Feature Environment Electromagnetic emissions and immunity Safety FSM7328S FSM7352S FSM7352PS Temperature • Operating: 32° to 104°F (0° to 40°C) • Storage: -4° to 158°F (-20° to 70°C) Humidity ... certified (CSA 22.2 #950) UL listed (UL 1950)/cUL IEC950/EN60950 Technical Specifications A-3 v1.0, March 2006 Hardware Installation Guide for Managed Stackable Layer 3 Fast Ethernet Switches Table A-1.
FSM7352S Hardware manual
Page 37
... GVRP Disabled GMRP Disabled IP routing Disabled Default Configuration Settings B-1 v1.0, March 2006 Appendix B Default Configuration Settings This appendix provides the default settings for the NETGEAR Model FSM7328S, FSM7352S, and FSM7352PS switches.
... GVRP Disabled GMRP Disabled IP routing Disabled Default Configuration Settings B-1 v1.0, March 2006 Appendix B Default Configuration Settings This appendix provides the default settings for the NETGEAR Model FSM7328S, FSM7352S, and FSM7352PS switches.