...Updated on February 3, 2011 This file contains information about NEC projector control commands. Connection Method 3. Interface Conditions 4. Projector Control NEC projectors make use of control commands that control the functions of Commands 5. List of the projector via connection with a personal computer or another device. ...LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41/NP61/NP62 Series NP1000 : NP1000/NP2000 Series NP3150 : NP1150/NP2150/NP3150/NP3151W Series NP4000 : NP4000/NP4001 Series NP905 : NP905/...
...Updated on February 3, 2011 This file contains information about NEC projector control commands. Connection Method 3. Interface Conditions 4. Projector Control NEC projectors make use of control commands that control the functions of Commands 5. List of the projector via connection with a personal computer or another device. ...LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41/NP61/NP62 Series NP1000 : NP1000/NP2000 Series NP3150 : NP1150/NP2150/NP3150/NP3151W Series NP4000 : NP4000/NP4001 Series NP905 : NP905/...
NP115 : RS232 codes- Projectors
Page 2
... USB connection using a wireless LAN unit A wireless LAN unit is required Status of connection methods are required. 3-2. LAN connection using the USB port on the projector A USB cable is required. 3-3.LAN connection using a wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. ...1. 2. LAN connection using a wireless LAN card A wireless LAN card is required. 3. LAN connection using the LAN port on the projector A serial cable is required. 3-4. Serial connection using the serial port on the...
... USB connection using a wireless LAN unit A wireless LAN unit is required Status of connection methods are required. 3-2. LAN connection using the USB port on the projector A USB cable is required. 3-3.LAN connection using a wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. ...1. 2. LAN connection using a wireless LAN card A wireless LAN card is required. 3. LAN connection using the LAN port on the projector A serial cable is required. 3-4. Serial connection using the serial port on the...
NP115 : RS232 codes- Projectors
Page 4
... is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". Setting method: Under projector [Projector Options] --> [Setup], enter a check for [Idle Mode] on Page 4. ( CAUTION ) (!1) Before making connections, be sure to the RS... [STANDBY MODE]. (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING"...
... is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". Setting method: Under projector [Projector Options] --> [Setup], enter a check for [Idle Mode] on Page 4. ( CAUTION ) (!1) Before making connections, be sure to the RS... [STANDBY MODE]. (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING"...
NP115 : RS232 codes- Projectors
Page 5
...comprises a header, a data portion, and a checksum. Acknowledge (hereafter referred to as ACK) that fails to as a response. Command | | | Controller | | Projector | | | Response (ACK or NAK) 4-1. Frame Format: | Header portion | Data portion |Checksum| | | (Max. 4095 Bytes) | | |1|2|3| 4 ...| Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is referred to as NAK) that recognizes a command and Negative Acknowledge (hereafter referred to recognize...
...comprises a header, a data portion, and a checksum. Acknowledge (hereafter referred to as ACK) that fails to as a response. Command | | | Controller | | Projector | | | Response (ACK or NAK) 4-1. Frame Format: | Header portion | Data portion |Checksum| | | (Max. 4095 Bytes) | | |1|2|3| 4 ...| Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is referred to as NAK) that recognizes a command and Negative Acknowledge (hereafter referred to recognize...
NP115 : RS232 codes- Projectors
Page 6
...basis Broadcast notification is recommended. * When the controller is connected with the projector on a one basis Broadcast notification is recommended. * When the controller is a projector ID for the projector that sends and receives commands. (individual notification) Entering 00H or FFH becomes ... Entering 0000B or 1111B becomes a common command for all the projectors. (broadcast notification) This is convenient for controlling multiple projectors at the same time. * When the controller is connected with the projector on a one-to each command description.) Response : This returns ...
...basis Broadcast notification is recommended. * When the controller is connected with the projector on a one basis Broadcast notification is recommended. * When the controller is a projector ID for the projector that sends and receives commands. (individual notification) Entering 00H or FFH becomes ... Entering 0000B or 1111B becomes a common command for all the projectors. (broadcast notification) This is convenient for controlling multiple projectors at the same time. * When the controller is connected with the projector on a one-to each command description.) Response : This returns ...
NP115 : RS232 codes- Projectors
Page 7
...Data length : (12 Bit) This is data length of individual notification or broadcast notification. Response : This returns the model code for a projector received regardless of data portion (unit:: byte). Data portion of data length. Command : This sets data added to a command to send...This sets data length of data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is recommended. Table of Model codes 0000B : (broadcast notification) 0001B : MT Series 0010B : LT Series 0011B ...
...Data length : (12 Bit) This is data length of individual notification or broadcast notification. Response : This returns the model code for a projector received regardless of data portion (unit:: byte). Data portion of data length. Command : This sets data added to a command to send...This sets data length of data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is recommended. Table of Model codes 0000B : (broadcast notification) 0001B : MT Series 0010B : LT Series 0011B ...
NP115 : RS232 codes- Projectors
Page 10
... CONROL 097-198. PIP/SIDE BY SIDE REQUEST 098-196. PIP/SIDE BY SIDE SET 110. AUTO FUNCTIONS EXECUTE 111. BASE MODEL TYPE REQUEST 305-3. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
... CONROL 097-198. PIP/SIDE BY SIDE REQUEST 098-196. PIP/SIDE BY SIDE SET 110. AUTO FUNCTIONS EXECUTE 111. BASE MODEL TYPE REQUEST 305-3. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
NP115 : RS232 codes- Projectors
Page 12
... of MT/NP1000 series In case of MT/NP3150 series In case of MT/NP3250 series In case of LT/LT80 series In case of NP61, NP62 series In case of NP216 series In case of VT series In case of NP600 series In case of NP610 series In case of..., NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S, NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the projector. (*2) Model code: "xxH" inscription This will differ depending on the projector. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version 1.04...
... of MT/NP1000 series In case of MT/NP3150 series In case of MT/NP3250 series In case of LT/LT80 series In case of NP61, NP62 series In case of NP216 series In case of VT series In case of NP600 series In case of NP610 series In case of..., NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S, NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the projector. (*2) Model code: "xxH" inscription This will differ depending on the projector. LT30 : NP4000: NP4001: NP62 : firmware version 1.03 or later firmware version 1.04...
NP115 : RS232 codes- Projectors
Page 13
Command: 00H C0H 00H 00H 00H C0H Response: At the time of the projector. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of a success NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/... condition) 1 = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of the...
Command: 00H C0H 00H 00H 00H C0H Response: At the time of the projector. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of a success NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/... condition) 1 = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of the...
NP115 : RS232 codes- Projectors
Page 14
DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number...
DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number...
NP115 : RS232 codes- Projectors
Page 16
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
NP115 : RS232 codes- Projectors
Page 19
... various bits are normal is "0" and error is "1". * "None" is "0" fixation. 009. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector. DATA01 Error Status (1) bit0 : Lamp cover error bit1 : Temperature error(Bimetal) bit2 : None bit3 : None bit4 : Fan error bit5 : Power error bit6 : Lamp(or Lamp1...
... various bits are normal is "0" and error is "1". * "None" is "0" fixation. 009. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector. DATA01 Error Status (1) bit0 : Lamp cover error bit1 : Temperature error(Bimetal) bit2 : None bit3 : None bit4 : Fan error bit5 : Power error bit6 : Lamp(or Lamp1...
NP115 : RS232 codes- Projectors
Page 20
... of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. Command: 02H 03H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 Switching object 00H... the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. POWER ON Function: This command switches on processing. 016. Supplement: (!) LT/LT80/HT: "None" 015...
... of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. Command: 02H 03H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 Switching object 00H... the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. POWER ON Function: This command switches on processing. 016. Supplement: (!) LT/LT80/HT: "None" 015...
NP115 : RS232 codes- Projectors
Page 27
... Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode (values) of a failure A3H 8AH 01H xxH 02H DATA01 DATA02 CKS ...: (!) Lamp Hour Meter This is also displayed with truncated a number after decimal point. 037-1. DATA98 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second) DATA91...
... Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of use is displayed in terms of Normal mode (values) of a failure A3H 8AH 01H xxH 02H DATA01 DATA02 CKS ...: (!) Lamp Hour Meter This is also displayed with truncated a number after decimal point. 037-1. DATA98 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second) DATA91...
NP115 : RS232 codes- Projectors
Page 29
... DATA03 DATA04 DATA05 DATA06: lamp's use of a success 23H 96H 01H xxH 06H DATA01 .. LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to 18000 seconds 037-4. Command: 03H 96H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion...
... DATA03 DATA04 DATA05 DATA06: lamp's use of a success 23H 96H 01H xxH 06H DATA01 .. LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to 18000 seconds 037-4. Command: 03H 96H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion...
NP115 : RS232 codes- Projectors
Page 30
LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. value will change to 360000 seconds Remaining time until lamp warning message starts ...
LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. value will change to 360000 seconds Remaining time until lamp warning message starts ...
NP115 : RS232 codes- Projectors
Page 31
... B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time This ...Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total ...
... B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage time This ...Example) The case of Lamp Use Prohibited Time 2100[H] A Lamp Use Warning Starting Time 2000[H] Model. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total ...
NP115 : RS232 codes- Projectors
Page 32
... a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. 039. LAMP MODE SET Function: This command sets the lamp mode of...
... a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. 039. LAMP MODE SET Function: This command sets the lamp mode of...
NP115 : RS232 codes- Projectors
Page 33
... DATA01 DATA02 CKS 7. This returns ACK with adding data to the command that requests data. * At the time of a failure( NAK ) This adds a cause of projector. Table of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 6. Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 C3H...
... DATA01 DATA02 CKS 7. This returns ACK with adding data to the command that requests data. * At the time of a failure( NAK ) This adds a cause of projector. Table of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 6. Command: 03H B1H 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 C3H...
NP115 : RS232 codes- Projectors
Page 34
Specified terminal is unavailable or cannot be selected. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Setting not possible. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number ...
Specified terminal is unavailable or cannot be selected. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Setting not possible. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number ...