.../LT260/LT260K/LT245/LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41/NP61/NP62 Series NP1000 : NP1000/NP2000 Series NP3150 : NP1150/NP2150/NP3150/NP3151W Series NP4000 : NP4000/NP4001 Series NP905 : NP905/NP901W/VT800 Series NP600... M300: M260X/M260W/M300X/M300W Series P420 P350X/P350W /P420X Series Contents 1. List of Commands 5. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about...
.../LT260/LT260K/LT245/LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41/NP61/NP62 Series NP1000 : NP1000/NP2000 Series NP3150 : NP1150/NP2150/NP3150/NP3151W Series NP4000 : NP4000/NP4001 Series NP905 : NP905/NP901W/VT800 Series NP600... M300: M260X/M260W/M300X/M300W Series P420 P350X/P350W /P420X Series Contents 1. List of Commands 5. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about...
NP115 : RS232 codes- Projectors
Page 2
... wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. 1. LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. LAN connection using a wireless LAN card A wireless LAN card is required. 3-3.LAN ...unit A wireless LAN unit is required. 3-4. Connection Method The following 3 kinds of supported connection USB connection using the serial port on the projector A USB cable is required. 2. 2. LAN connection 3-1. Serial connection using the USB port on the...
... wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. 1. LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. LAN connection using a wireless LAN card A wireless LAN card is required. 3-3.LAN ...unit A wireless LAN unit is required. 3-4. Connection Method The following 3 kinds of supported connection USB connection using the serial port on the projector A USB cable is required. 2. 2. LAN connection 3-1. Serial connection using the USB port on the...
NP115 : RS232 codes- Projectors
Page 4
... is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". The projector cannot use the control commands in the standby mode. Interface Conditions Serial connection The communications method conforms to the RS-232C standard.... (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" ...
... is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". The projector cannot use the control commands in the standby mode. Interface Conditions Serial connection The communications method conforms to the RS-232C standard.... (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" ...
NP115 : RS232 codes- Projectors
Page 5
... Frame Format One frame comprises a header, a data portion, and a checksum. Communication Frame On the LT/MT/SX/GT series projectors communication is referred to each command description.) 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of PC.... 4095 Bytes) | | |1|2|3| 4 |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is an identification data assigned to as NAK) that fails to send it. ( See each command. Command : This sets...
... Frame Format One frame comprises a header, a data portion, and a checksum. Communication Frame On the LT/MT/SX/GT series projectors communication is referred to each command description.) 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of PC.... 4095 Bytes) | | |1|2|3| 4 |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is an identification data assigned to as NAK) that fails to send it. ( See each command. Command : This sets...
NP115 : RS232 codes- Projectors
Page 6
...ID2: (8 Bit) This is an identification data assigned to -one basis Broadcast notification is recommended. * When the controller is connected with the projector on a one-to each command description.) Response : This returns the value of received ID1 as LOW (recognized); Command : This sets an ...individually, specifying a model code from the following model codes is required. * Model code: (4 Bit) This is a model code for the projector that sends commands. (individual notification) Entering 0000B or 1111B becomes a common command for NAK it sends the 8th bit back as HIGH. for...
...ID2: (8 Bit) This is an identification data assigned to -one basis Broadcast notification is recommended. * When the controller is connected with the projector on a one-to each command description.) Response : This returns the value of received ID1 as LOW (recognized); Command : This sets an ...individually, specifying a model code from the following model codes is required. * Model code: (4 Bit) This is a model code for the projector that sends commands. (individual notification) Entering 0000B or 1111B becomes a common command for NAK it sends the 8th bit back as HIGH. for...
NP115 : RS232 codes- Projectors
Page 7
...command description.) Response : This sets data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is recommended. The lower ranking 4 bits becomes the upper bits of data length. * Data length : (12 Bit) This... is model code. * Data portion This becomes data of response Response : This returns the model code for a projector received regardless of one transmit and receive data frame. 4-2. Command : This sets data added to a command to send it . ( See each ...
...command description.) Response : This sets data added to a response to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is recommended. The lower ranking 4 bits becomes the upper bits of data length. * Data length : (12 Bit) This... is model code. * Data portion This becomes data of response Response : This returns the model code for a projector received regardless of one transmit and receive data frame. 4-2. Command : This sets data added to a command to send it . ( See each ...
NP115 : RS232 codes- Projectors
Page 10
... 039. REMOTE KEY CODE 060. GAIN PARAMETER REQUEST 2 077. MIRROR COVER STATUS REQUEST 079. WXGA MODE SETTING SET 098-198. BASE MODEL TYPE REQUEST 305-3. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
... 039. REMOTE KEY CODE 060. GAIN PARAMETER REQUEST 2 077. MIRROR COVER STATUS REQUEST 079. WXGA MODE SETTING SET 098-198. BASE MODEL TYPE REQUEST 305-3. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
NP115 : RS232 codes- Projectors
Page 12
...NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value when forwarding a factory. See "NAK" of response". (*5) Term "RGB" and "COMPUTER" On the HT1100, VT770,.../NP500WS/NP600/NP600S, NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S, NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the projector. (*2) Model code: "xxH" inscription This will differ depending on the...
...NP3151W, NP1250/NP2250/NP3250/NP3250W, NP1200/NP2200, NP4000/NP4001, NP4100/NP4100W, NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S, Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value when forwarding a factory. See "NAK" of response". (*5) Term "RGB" and "COMPUTER" On the HT1100, VT770,.../NP500WS/NP600/NP600S, NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S, NP40/NP50/NP60/NP41/NP61/NP62/NP43/NP64 and P350X/350W/420X, the term "RGB connector" has been changed to the projector. (*2) Model code: "xxH" inscription This will differ depending on the...
NP115 : RS232 codes- Projectors
Page 13
...1 = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of a success NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the... term "DVI connector" has been changed to "COMPUTER". 006. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. RUNNING SENSE Function: This command acquires the operation mode of the...
...1 = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of a success NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the... term "DVI connector" has been changed to "COMPUTER". 006. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. RUNNING SENSE Function: This command acquires the operation mode of the...
NP115 : RS232 codes- Projectors
Page 14
20H C0H 01H xxH 80H DATA01 .. DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06...
20H C0H 01H xxH 80H DATA01 .. DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06...
NP115 : RS232 codes- Projectors
Page 16
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
NP115 : RS232 codes- Projectors
Page 19
... The various bits are normal is "0" and error is "1". * "None" is "0" fixation. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At the time of a failure A0H 88H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)
... The various bits are normal is "0" and error is "1". * "None" is "0" fixation. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At the time of a failure A0H 88H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)
NP115 : RS232 codes- Projectors
Page 20
... time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. Command: 02H 00H 00H 00H 00H 02H Response: At the time of a success 22H 00H 01H ...the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. POWER OFF Function: This command switches off processing. (It contains a cooling period.) 018. INPUT SW CHANGE...
... time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off the main power of the projector. Command: 02H 00H 00H 00H 00H 02H Response: At the time of a success 22H 00H 01H ...the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the projector. POWER OFF Function: This command switches off processing. (It contains a cooling period.) 018. INPUT SW CHANGE...
NP115 : RS232 codes- Projectors
Page 27
...(*4) (*3) Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. DATA98 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second...) DATA91 .. 94 : Panel Usage (second) DATA95 .. 98 : Projector Usage (second) Response: At the time of a success 23H 8AH 01H xxH 62H DATA01 .. DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 04...
...(*4) (*3) Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. DATA98 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 49 : Projector name (NULL termination character string) DATA50 .. 82 : Reserved DATA83 .. 86 : Lamp Hour Meter (second) (!) DATA87 .. 90 : Filter Usage (second...) DATA91 .. 94 : Panel Usage (second) DATA95 .. 98 : Projector Usage (second) Response: At the time of a success 23H 8AH 01H xxH 62H DATA01 .. DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 04...
NP115 : RS232 codes- Projectors
Page 29
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to HEX 2) Punch in Eco mode. value will change to appear (in terms of Eco ...
LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to HEX 2) Punch in Eco mode. value will change to appear (in terms of Eco ...
NP115 : RS232 codes- Projectors
Page 30
LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : ... to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of Eco mode values) It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. Lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining...
LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : ... to appear (in terms of specified values) 03H 96H 00H 00H 02H 00H 08H A3H Example of Eco mode values) It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. Lamp's use of hours = 18000/3600 = 5 hours * In case of acquiring the remaining...
NP115 : RS232 codes- Projectors
Page 31
...Lamp Use Warning Starting Time) Example) The case of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total usage.... LAMP MODE REQUEST Function: This command acquires the setting of the lamp mode of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage...
...Lamp Use Warning Starting Time) Example) The case of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total usage.... LAMP MODE REQUEST Function: This command acquires the setting of the lamp mode of projector. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer for normal lamp mode conversion. (!3) Lamp usage...
NP115 : RS232 codes- Projectors
Page 32
...02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. 039. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B1H 01H xxH 02H DATA01 DATA02... CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. LAMP MODE SET Function: This command sets the lamp mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)
...02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. 039. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B1H 01H xxH 02H DATA01 DATA02... CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. LAMP MODE SET Function: This command sets the lamp mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)
NP115 : RS232 codes- Projectors
Page 33
... returns ACK with adding data to the data portion for the command that requests data. * At the time of a failure( NAK ) This adds a cause of projector. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of not accepting the command to data portion to the command that does not...
... returns ACK with adding data to the data portion for the command that requests data. * At the time of a failure( NAK ) This adds a cause of projector. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of not accepting the command to data portion to the command that does not...
NP115 : RS232 codes- Projectors
Page 34
... WHITE BAL 43 2BH 00H IMAGE 44 2CH 00H TEST Invalid values specified. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Specified terminal is unavailable or cannot be selected. This current model does not support this function. Setting not possible. DATA01 DATA2 Error Error Types description...
... WHITE BAL 43 2BH 00H IMAGE 44 2CH 00H TEST Invalid values specified. REMOTE KEY CODE Function: This command sends remote control key codes of projector. Specified terminal is unavailable or cannot be selected. This current model does not support this function. Setting not possible. DATA01 DATA2 Error Error Types description...