Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 5
... SATA or SAS hard disk drives . . . 46 Entering the LSI MegaRAID BIOS configuration utility 47 Creating RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 47 Deleting RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 48 Setting the hot spare hard disk...Replacing the rear fan assembly 81 iii Contents Chapter 1. General information . . . . 29 Specifications 29 Lenovo ThinkVantage Tools 29 Lenovo Solution Center 30 Lenovo Welcome 30 Product Recovery 30 SimpleTap 30 ThinkVantage Rescue and Recovery 30 Additional information resources 31 Chapter 4. ...
... SATA or SAS hard disk drives . . . 46 Entering the LSI MegaRAID BIOS configuration utility 47 Creating RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 47 Deleting RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 48 Setting the hot spare hard disk...Replacing the rear fan assembly 81 iii Contents Chapter 1. General information . . . . 29 Specifications 29 Lenovo ThinkVantage Tools 29 Lenovo Solution Center 30 Lenovo Welcome 30 Product Recovery 30 SimpleTap 30 ThinkVantage Rescue and Recovery 30 Additional information resources 31 Chapter 4. ...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 49
...applicable in this chapter is needed. © Copyright Lenovo 2012 43 Improved reading performance and 100% redundancy • RAID Level 10 - A RAID Level 0 hard disk drive group consisting of four hard disk drives - Mirrored disk array - A RAID Level 10 hard disk drive group consisting of at ... Striped disk array - Supported strip size: 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB - Note: The RAID configuration information described in the Windows environment. Striped and mirrored disk array (a combination of two hard disk drives - Block-level striped disk array with...
...applicable in this chapter is needed. © Copyright Lenovo 2012 43 Improved reading performance and 100% redundancy • RAID Level 10 - A RAID Level 0 hard disk drive group consisting of four hard disk drives - Mirrored disk array - A RAID Level 10 hard disk drive group consisting of at ... Striped disk array - Supported strip size: 4 KB, 8 KB, 16 KB, 32 KB, 64 KB, or 128 KB - Note: The RAID configuration information described in the Windows environment. Striped and mirrored disk array (a combination of two hard disk drives - Block-level striped disk array with...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 50
... RSTe configuration utility. Create RAID Volume 2. To create a RAID volume, do the following four options are displayed after you configure an option, press Tab or Enter to go to the next option. Enter the Intel RSTe configuration utility. The following : 44 ThinkStation Hardware Maintenance Manual Name:...Entering the Intel RSTe configuration utility" on page 87. After you enter the Intel RSTe configuration utility: 1. You can change the RAID Level to five hard disk drives) is installed with the Intel RSTe configuration utility. For more than one of the following five ...
... RSTe configuration utility. Create RAID Volume 2. To create a RAID volume, do the following four options are displayed after you configure an option, press Tab or Enter to go to the next option. Enter the Intel RSTe configuration utility. The following : 44 ThinkStation Hardware Maintenance Manual Name:...Entering the Intel RSTe configuration utility" on page 87. After you enter the Intel RSTe configuration utility: 1. You can change the RAID Level to five hard disk drives) is installed with the Intel RSTe configuration utility. For more than one of the following five ...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 51
.... To reset hard disk drives to Degraded. In this section are prompted to select a hard disk drive to confirm the deletion of the new RAID volume. 5. Press the up and down arrow keys to guide you reset is a bootable volume. Press Del to complete the configuration. Enter the... Intel RSTe configuration utility. Configuring RAID 45 d. Press Enter to delete RAID volumes. If the hard disk drive you through a quick setup of the menu to select hard disk drives, and then press ...
.... To reset hard disk drives to Degraded. In this section are prompted to select a hard disk drive to confirm the deletion of the new RAID volume. 5. Press the up and down arrow keys to guide you reset is a bootable volume. Press Del to complete the configuration. Enter the... Intel RSTe configuration utility. Configuring RAID 45 d. Press Enter to delete RAID volumes. If the hard disk drive you through a quick setup of the menu to select hard disk drives, and then press ...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 52
... this adapter, refer to loss of at http://support.lenovo.com/en_US/guides-and-manuals/detail.page?DocID=UM007543. Mirrored disk array - A combination of two or four hard disk drives - A RAID Level 6 hard disk drive group consisting of RAID 0 hard disk drive groups - Supported strip size: ... both high data transfer rates and complete data redundancy • RAID Level 5 - using the LSI MegaRAID BIOS configuration utility" on page 48 • "Setting the hot spare hard disk drive" on the system board. 46 ThinkStation Hardware Maintenance Manual Supported strip size: 8 KB to 1 MB...
... this adapter, refer to loss of at http://support.lenovo.com/en_US/guides-and-manuals/detail.page?DocID=UM007543. Mirrored disk array - A combination of two or four hard disk drives - A RAID Level 6 hard disk drive group consisting of RAID 0 hard disk drive groups - Supported strip size: ... both high data transfer rates and complete data redundancy • RAID Level 5 - using the LSI MegaRAID BIOS configuration utility" on page 48 • "Setting the hot spare hard disk drive" on the system board. 46 ThinkStation Hardware Maintenance Manual Supported strip size: 8 KB to 1 MB...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 53
... Drive Groups. The following : a. To create hard disk drive groups, do the following : 1. The Span Definition window is displayed. Configuring RAID 47 b. Click Add To Array to move the selected hard disk drives to enter the Choosing the Configuration Type window. 2. Click Next. Select... disk drive). Chapter 7. During the computer startup, follow the instructions on how to create the hard disk drive group. To create RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on the screen to enter the CONTROLLER SELECTION window. 3. To...
... Drive Groups. The following : a. To create hard disk drive groups, do the following : 1. The Span Definition window is displayed. Configuring RAID 47 b. Click Add To Array to move the selected hard disk drives to enter the Choosing the Configuration Type window. 2. Click Next. Select... disk drive). Chapter 7. During the computer startup, follow the instructions on how to create the hard disk drive group. To create RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on the screen to enter the CONTROLLER SELECTION window. 3. To...
Hardware Maintenance Manual (HMM) - ThinkStation D30
Page 54
...RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on how to set the hot spare hard disk drive. Click the virtual hard disk drives you want to save your changes. To set as a hot spare hard disk drive in the right pane. 48 ThinkStation... is listed as the hot spare hard disk drive. Setting the hot spare hard disk drive This section provides instructions on how to delete RAID volumes using the LSI MegaRAID BIOS configuration utility, do the following : 1. Enter the LSI MegaRAID BIOS configuration utility. The Drive window is...
...RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on how to set the hot spare hard disk drive. Click the virtual hard disk drives you want to save your changes. To set as a hot spare hard disk drive in the right pane. 48 ThinkStation... is listed as the hot spare hard disk drive. Setting the hot spare hard disk drive This section provides instructions on how to delete RAID volumes using the LSI MegaRAID BIOS configuration utility, do the following : 1. Enter the LSI MegaRAID BIOS configuration utility. The Drive window is...
(English) User Guide
Page 4
... help, and service 103 Information resources 103 Lenovo ThinkVantage Tools 103 Lenovo Welcome 103 Help and Support 103 Safety and Warranty 103 Lenovo Web site (http://www.lenovo.com) . . 103 Lenovo Support Web site 104 ii ThinkStation User Guide Troubleshooting and diagnostics 85 Basic troubleshooting ... SAS hard disk drives . . . 76 Entering the LSI MegaRAID BIOS configuration utility 77 Creating RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 77 Deleting RAID volumes using a rescue medium 62 Creating a rescue medium 62 Using a rescue medium 62 Reinstalling...
... help, and service 103 Information resources 103 Lenovo ThinkVantage Tools 103 Lenovo Welcome 103 Help and Support 103 Safety and Warranty 103 Lenovo Web site (http://www.lenovo.com) . . 103 Lenovo Support Web site 104 ii ThinkStation User Guide Troubleshooting and diagnostics 85 Basic troubleshooting ... SAS hard disk drives . . . 76 Entering the LSI MegaRAID BIOS configuration utility 77 Creating RAID volumes using the LSI MegaRAID BIOS configuration utility . . . . 77 Deleting RAID volumes using a rescue medium 62 Creating a rescue medium 62 Using a rescue medium 62 Reinstalling...
(English) User Guide
Page 13
...SCSI (SAS) hard disk drive (supported with one of models. Chapter 1. Microprocessor Your computer comes with optional hard disk drive enablement module or raid on chip (ROC) card) • Serial Advanced Technology Attachment (SATA) hard disk drive • Solid state drive (SSD) Video subsystem...Setup Utility program by following : • Go into the available PCI Express slots on the front panel • Internal speaker © Copyright Lenovo 2012 1 Audio subsystem • Integrated high-definition (HD) audio • Audio line-in Chapter 7 "Using the Setup Utility program" on...
...SCSI (SAS) hard disk drive (supported with one of models. Chapter 1. Microprocessor Your computer comes with optional hard disk drive enablement module or raid on chip (ROC) card) • Serial Advanced Technology Attachment (SATA) hard disk drive • Solid state drive (SSD) Video subsystem...Setup Utility program by following : • Go into the available PCI Express slots on the front panel • Internal speaker © Copyright Lenovo 2012 1 Audio subsystem • Integrated high-definition (HD) audio • Audio line-in Chapter 7 "Using the Setup Utility program" on...
(English) User Guide
Page 14
...test (POST) hardware test results • Desktop Management Interface (DMI) Desktop Management Interface provides a common path for SATA or SAS RAID 0, 1, 5, and 10 arrays on specific Intel chipset system boards to enhance hard disk drive performance. • Preboot Execution Environment (... computers using a network interface independent of data storage devices (such as Wake on the front panel (varies by model) 2 ThinkStation User Guide It provides an operating system interface through which instrumented components provide information and notification. Input/Output (I/O) features • ...
...test (POST) hardware test results • Desktop Management Interface (DMI) Desktop Management Interface provides a common path for SATA or SAS RAID 0, 1, 5, and 10 arrays on specific Intel chipset system boards to enhance hard disk drive performance. • Preboot Execution Environment (... computers using a network interface independent of data storage devices (such as Wake on the front panel (varies by model) 2 ThinkStation User Guide It provides an operating system interface through which instrumented components provide information and notification. Input/Output (I/O) features • ...
(English) User Guide
Page 85
... Configuring RAID with distributed parity - Better performance and fault tolerance Ensure that your computer comes with Intel RSTe, you can be enabled by Intel Rapid Storage Technology enterprise (RSTe) or the LSI MegaRAID BIOS. This section provides information about the following hard disk drive enablement modules is needed. © Copyright Lenovo 2012...
... Configuring RAID with distributed parity - Better performance and fault tolerance Ensure that your computer comes with Intel RSTe, you can be enabled by Intel Rapid Storage Technology enterprise (RSTe) or the LSI MegaRAID BIOS. This section provides information about the following hard disk drive enablement modules is needed. © Copyright Lenovo 2012...
(English) User Guide
Page 86
...: 74 ThinkStation User Guide This section provides information about the hard disk drive enablement module, refer to "Installing or replacing a hard disk drive enablement module" on page 52. The following : 1. Reset Disks to enter the Intel RSTe configuration utility. Exit Press the up and down arrow keys to select Create RAID Volume...
...: 74 ThinkStation User Guide This section provides information about the hard disk drive enablement module, refer to "Installing or replacing a hard disk drive enablement module" on page 52. The following : 1. Reset Disks to enter the Intel RSTe configuration utility. Exit Press the up and down arrow keys to select Create RAID Volume...
(English) User Guide
Page 87
...74. 2. When prompted, press Y to initiate the rebuild process. If the hard disk drive you through a quick setup of the selected RAID volume. Select an available hard disk drive, and then press Enter to confirm the reset action. 5. Press the up and down arrow keys...the degraded status. Enter the Intel RSTe configuration utility. • RAID Level 0 • RAID Level 1 • RAID Level 10 • RAID Level 5 c. Strip Size: Press the up and down arrow keys to non-RAID, do the following : 1. To delete a RAID volume, do the following : 1. To reset hard disk drives to...
...74. 2. When prompted, press Y to initiate the rebuild process. If the hard disk drive you through a quick setup of the selected RAID volume. Select an available hard disk drive, and then press Enter to confirm the reset action. 5. Press the up and down arrow keys...the degraded status. Enter the Intel RSTe configuration utility. • RAID Level 0 • RAID Level 1 • RAID Level 10 • RAID Level 5 c. Strip Size: Press the up and down arrow keys to non-RAID, do the following : 1. To delete a RAID volume, do the following : 1. To reset hard disk drives to...
(English) User Guide
Page 88
...groups - Supported strip size: 8 KB to the connectors on all models of LSI MegaRAID adapter • RAID Level 6 - RAID Level 6 might not be available on the system board. 76 ThinkStation User Guide Spanned hard disk drive group with distributed parity - Better performance and fault tolerance...levels of at http://support.lenovo.com/en_US/guides-and-manuals/detail.page?DocID=UM007543. A RAID Level 00 hard disk drive group consisting of two or four hard disk drives - A RAID Level 5 hard disk drive group consisting of RAID: • RAID Level 0 - RAID Level 5 might not ...
...groups - Supported strip size: 8 KB to the connectors on all models of LSI MegaRAID adapter • RAID Level 6 - RAID Level 6 might not be available on the system board. 76 ThinkStation User Guide Spanned hard disk drive group with distributed parity - Better performance and fault tolerance...levels of at http://support.lenovo.com/en_US/guides-and-manuals/detail.page?DocID=UM007543. A RAID Level 00 hard disk drive group consisting of two or four hard disk drives - A RAID Level 5 hard disk drive group consisting of RAID: • RAID Level 0 - RAID Level 5 might not ...
(English) User Guide
Page 89
... Type window. 2. Select Manual Configuration, and then click Next. b. d. The Virtual Drive Definition window is displayed. Creating RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on the WebBIOS main screen to select one hard disk drive...Manually create hard disk drive groups and virtual hard disk drives, and set parameters. • Automatic Configuration: Automatically create an optimal RAID configuration. 4. Select one or more hard disk drives for the group (keep pressing Ctrl while selecting more than one of the three...
... Type window. 2. Select Manual Configuration, and then click Next. b. d. The Virtual Drive Definition window is displayed. Creating RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on the WebBIOS main screen to select one hard disk drive...Manually create hard disk drive groups and virtual hard disk drives, and set parameters. • Automatic Configuration: Automatically create an optimal RAID configuration. 4. Select one or more hard disk drives for the group (keep pressing Ctrl while selecting more than one of the three...
(English) User Guide
Page 90
... utility. See "Entering the LSI MegaRAID BIOS configuration utility" on page 77. 2. Click the hard disk drive you want to delete RAID volumes using the LSI MegaRAID BIOS configuration utility. The Drive window is listed as the hot spare hard disk drive. To delete...LSI MegaRAID BIOS configuration utility, do the following : 1. Deleting RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on how to set as a hot spare hard disk drive in the right pane. 78 ThinkStation User Guide Click the virtual hard disk drives you want to...
... utility. See "Entering the LSI MegaRAID BIOS configuration utility" on page 77. 2. Click the hard disk drive you want to delete RAID volumes using the LSI MegaRAID BIOS configuration utility. The Drive window is listed as the hot spare hard disk drive. To delete...LSI MegaRAID BIOS configuration utility, do the following : 1. Deleting RAID volumes using the LSI MegaRAID BIOS configuration utility This section provides instructions on how to set as a hot spare hard disk drive in the right pane. 78 ThinkStation User Guide Click the virtual hard disk drives you want to...
(English) User Guide
Page 103
..." on page 69. • If you have configured the hard disk drives correctly. See "Lenovo Solution Center" on page 101. Refer to five hard disk drives) is installed. Refer to Chapter 8 "Configuring RAID" on page 73. See "Lenovo Solution Center" on page 101. Note: In rare cases, the hard disk drive with SAS...
..." on page 69. • If you have configured the hard disk drives correctly. See "Lenovo Solution Center" on page 101. Refer to five hard disk drives) is installed. Refer to Chapter 8 "Configuring RAID" on page 73. See "Lenovo Solution Center" on page 101. Note: In rare cases, the hard disk drive with SAS...
(Arabic) User Guide
Page 74
... RSTe RAID RAID Intel RSTe Intel RSTe Create RAID Volume Enter CREATE VOLUME .MENU Tab Enter Name .a :RAID Level .b RAID RAID Level 0 RAID Level 1 • RAID Level 10 RAID Level 5 :Disks .c Enter SELECT DISKS MENU Enter :Strip Size .d Capacity .e RAID RAID ThinkStation...
... RSTe RAID RAID Intel RSTe Intel RSTe Create RAID Volume Enter CREATE VOLUME .MENU Tab Enter Name .a :RAID Level .b RAID RAID Level 0 RAID Level 1 • RAID Level 10 RAID Level 5 :Disks .c Enter SELECT DISKS MENU Enter :Strip Size .d Capacity .e RAID RAID ThinkStation...
(Arabic) User Guide
Page 90
DVD 864 × 1152 CD-ROM CD-RW DVD-ROM DVD DVD Lenovo Solution Center Setup Utility No Operating System Found Setup Utility Setup Utility SATA ) SATA SAS SASﻣﻦ LSI MegaRAID SAS Lenovo Solution Center Lenovo Solution Center No Operating System Found No Operating System Found Setup Utility RAID RAID Rescue and Recovery ThinkStation
DVD 864 × 1152 CD-ROM CD-RW DVD-ROM DVD DVD Lenovo Solution Center Setup Utility No Operating System Found Setup Utility Setup Utility SATA ) SATA SAS SASﻣﻦ LSI MegaRAID SAS Lenovo Solution Center Lenovo Solution Center No Operating System Found No Operating System Found Setup Utility RAID RAID Rescue and Recovery ThinkStation
(Korean) User Guide
Page 4
... 또는 SAS 69 Intel RSTe SATA 또는 SAS RAID 70 LSI MegaRAID BIOS RAID 71 SATA 또는 SAS 72 LSI MegaRAID BIOS 73 LSI MegaRAID BIOS RAID 73 LSI MegaRAID BIOS RAID 74 74 제 9 75 75 BIOS 75 ii ThinkStation BIOS 75 POST/BIOS 76 제 10 77 77 77 77... System Update 77 78 78 78 80 80 제 11 81 81 82 82 83 CD 84 DVD 85 87 88 88 89 91 92 93 95 95 95 USB 96 Lenovo...
... 또는 SAS 69 Intel RSTe SATA 또는 SAS RAID 70 LSI MegaRAID BIOS RAID 71 SATA 또는 SAS 72 LSI MegaRAID BIOS 73 LSI MegaRAID BIOS RAID 73 LSI MegaRAID BIOS RAID 74 74 제 9 75 75 BIOS 75 ii ThinkStation BIOS 75 POST/BIOS 76 제 10 77 77 77 77... System Update 77 78 78 78 80 80 제 11 81 81 82 82 83 CD 84 DVD 85 87 88 88 89 91 92 93 95 95 95 USB 96 Lenovo...