Installation Instructions
Page 4
....6 inch) Air outlet vents Base plate Air Inlet Control cover Connecting wire Connection pipe Drain hose Air Discharge 4 Multi Air Conditioner Please see the information specific to your indoor unit type.
....6 inch) Air outlet vents Base plate Air Inlet Control cover Connecting wire Connection pipe Drain hose Air Discharge 4 Multi Air Conditioner Please see the information specific to your indoor unit type.
Installation Instructions
Page 29
... and the product side for correct installation. • If you install the extension cable in the opposite direction, the connector will not be connected. • Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above , use the extension cable. Check whether the connector is 10m and above . When the distance...
... and the product side for correct installation. • If you install the extension cable in the opposite direction, the connector will not be connected. • Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above , use the extension cable. Check whether the connector is 10m and above . When the distance...
Installation Instructions
Page 37
... the same as those of the outdoor unit and the terminal No. The wiring for the outdoor unit can not be comply with the following specifications: ETL recognized and CSA certified. Outdoor Unit Capacity Power source (Btu/h class) Fuse or breaker Capacity 18k 1ø,208/230V 15A 24k 1... Connect the cable to hold all wires together in place. RECOMMENDATION: The power cord connected to the outdoor unit should be comply with the following specifications: ETL recognized and CSA certified. 18 kBtu/h class AWG14 24/36 kBtu/h class AWG12 Line voltage (208/230V) GN/YL Line voltage (208/...
... the same as those of the outdoor unit and the terminal No. The wiring for the outdoor unit can not be comply with the following specifications: ETL recognized and CSA certified. Outdoor Unit Capacity Power source (Btu/h class) Fuse or breaker Capacity 18k 1ø,208/230V 15A 24k 1... Connect the cable to hold all wires together in place. RECOMMENDATION: The power cord connected to the outdoor unit should be comply with the following specifications: ETL recognized and CSA certified. 18 kBtu/h class AWG14 24/36 kBtu/h class AWG12 Line voltage (208/230V) GN/YL Line voltage (208/...
Service Manual
Page 2
LGE Internal Use Only Specification Indoor unit type Ceilling Cassette - 4way Model Decoration Panel Name AMNW12GTRA0[LMCN125HV] AMNW18GTQA0[LMCN185HV] PT-UQC PT-UQC Power Supply Capacity(*) Current Fan Running Current Motor Type Fan Type Ø / V / Hz ...Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB Piping Length - The specification may be subject to the combination table Conversion Formula kW = Btu/h class X 0.0002931 cfm = CMM x 35.3 Copyright ©2008 LG Electronics. All right reserved. Capacities are based on the following conditions: Cooling: ...
LGE Internal Use Only Specification Indoor unit type Ceilling Cassette - 4way Model Decoration Panel Name AMNW12GTRA0[LMCN125HV] AMNW18GTQA0[LMCN185HV] PT-UQC PT-UQC Power Supply Capacity(*) Current Fan Running Current Motor Type Fan Type Ø / V / Hz ...Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB Piping Length - The specification may be subject to the combination table Conversion Formula kW = Btu/h class X 0.0002931 cfm = CMM x 35.3 Copyright ©2008 LG Electronics. All right reserved. Capacities are based on the following conditions: Cooling: ...