Service Manual
Page 2
... ...4 Safety Precautions...5 Dimensions...11 Indoor Unit...11 Outdoor Unit ...12 Product Specifications ...13 Installation ...15 Installation Parts...15 Installation Tools...15 Select the best location ...16 Piping length and elevation ...17 Fixing Installation Plate(Standart Type 18 Preparing work for Installation (Artcool Type Only 19 Flaring Work and Connection of Piping 21 Flaring work...21...
... ...4 Safety Precautions...5 Dimensions...11 Indoor Unit...11 Outdoor Unit ...12 Product Specifications ...13 Installation ...15 Installation Parts...15 Installation Tools...15 Select the best location ...16 Piping length and elevation ...17 Fixing Installation Plate(Standart Type 18 Preparing work for Installation (Artcool Type Only 19 Flaring Work and Connection of Piping 21 Flaring work...21...
Service Manual
Page 5
... death or serious injury. er or fuse. • There is risk of fire or electric shock. • Improper wiring or installation may • There is risk of symbols used in this dealer, seller, a qualified electrician, appliance on a dedicated circuit. WARNING... use a defective or under- rated circuit breaker. Service Manual 5 WARNING This symbol indicates the possibility of control box securely. Install the panel and the cover Always install a dedicated cir- s Incorrect operation due to follow the instruction. The seriousness is risk of injury or damage to do. cuit...
... death or serious injury. er or fuse. • There is risk of fire or electric shock. • Improper wiring or installation may • There is risk of symbols used in this dealer, seller, a qualified electrician, appliance on a dedicated circuit. WARNING... use a defective or under- rated circuit breaker. Service Manual 5 WARNING This symbol indicates the possibility of control box securely. Install the panel and the cover Always install a dedicated cir- s Incorrect operation due to follow the instruction. The seriousness is risk of injury or damage to do. cuit...
Service Manual
Page 6
...not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. For installation, always contact the dealer or an Authorized Service Center. • There is risk of the case edges and the fins on the condenser and .... does not deteriorate with it, causing property damage, product failure, and personal injury. Do not place anything on a Be sure the installation area defective installation stand. Do not install, remove, or reinstall the unit by yourself (customer). • There is risk of fire or electric shock. 6 Multi type Air ...
...not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. For installation, always contact the dealer or an Authorized Service Center. • There is risk of the case edges and the fins on the condenser and .... does not deteriorate with it, causing property damage, product failure, and personal injury. Do not place anything on a Be sure the installation area defective installation stand. Do not install, remove, or reinstall the unit by yourself (customer). • There is risk of fire or electric shock. 6 Multi type Air ...
Service Manual
Page 8
... could step on connect the power supply plug or turn off when cleaning or maintaining the product. • There is risk of electric shock. s Installation CAUTION Always check for a long time, dis- ed operation. water is risk of fire, electric shock, or product damage. age. trostatic filter, if...Safety Precautions Do not open the inlet grill of the product When the product is soaked Be cautious that Keep level even when age after installation or repair of product. Turn the main power off the breaker. When the product is not be used for gas (refrigerant) leak- ...
... could step on connect the power supply plug or turn off when cleaning or maintaining the product. • There is risk of electric shock. s Installation CAUTION Always check for a long time, dis- ed operation. water is risk of fire, electric shock, or product damage. age. trostatic filter, if...Safety Precautions Do not open the inlet grill of the product When the product is soaked Be cautious that Keep level even when age after installation or repair of product. Turn the main power off the breaker. When the product is not be used for gas (refrigerant) leak- ...
Service Manual
Page 9
Do not install the product where it will be exposed to sea wind (salt spray) directly. • Avoid personal injury. • It may cause corrosion on the condenser ... when removing the air filter. Do not use the product for special purposes, such as preserving foods, works of personal injury. Safety Precautions Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. • It may cause a problem for your health. Use...
Do not install the product where it will be exposed to sea wind (salt spray) directly. • Avoid personal injury. • It may cause corrosion on the condenser ... when removing the air filter. Do not use the product for special purposes, such as preserving foods, works of personal injury. Safety Precautions Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. • It may cause a problem for your health. Use...
Service Manual
Page 11
Dimensions Indoor Unit 1. Art Cool Type Indoor Unit W D H Pipe Hole Hanger Hole Installation plate Fix Hole Dimension W H D Model mm mm mm Split Type S4 SE 9 kBtu/h 12 kBtu/h 840 895 270 282 153 165 ARTCOOL Type SP3 9 kBtu/h 12 kBtu/h 570 568 129 Service Manual 11 Split Type Indoor H D W Dimensions 2.
Dimensions Indoor Unit 1. Art Cool Type Indoor Unit W D H Pipe Hole Hanger Hole Installation plate Fix Hole Dimension W H D Model mm mm mm Split Type S4 SE 9 kBtu/h 12 kBtu/h 840 895 270 282 153 165 ARTCOOL Type SP3 9 kBtu/h 12 kBtu/h 570 568 129 Service Manual 11 Split Type Indoor H D W Dimensions 2.
Service Manual
Page 14
... CMM(CFM) Noise Level(H/L) at 230V Sound Press,1m dB(A) 1 SVC Valve Liquid inch(mm) Gas Dimensions W*H*D inch(mm) Net Weight Outdoor kg(lbs) Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity 20/40ft A3UC363FA0(LMU360CE) 9,000~36,000 2637~10...
... CMM(CFM) Noise Level(H/L) at 230V Sound Press,1m dB(A) 1 SVC Valve Liquid inch(mm) Gas Dimensions W*H*D inch(mm) Net Weight Outdoor kg(lbs) Max. Installation Indoor Unit~Outdoor Unit m Height Difference Indoor Unit~Indoor Unit m Packing Dimension W*H*D inch(mm) Stuffing Quantity 20/40ft A3UC363FA0(LMU360CE) 9,000~36,000 2637~10...
Service Manual
Page 15
Installation Read carefully, and then follow step by step. Installation Parts Installation plate Type "B" screw Installation Type "A" screw and plastic anchor Remote Control Holder Installation Tools Figure Name Screw driver Electric Drill Measuring Tape, Knife Hole Core Drill Spanner Torque wrench Figure Name Ohmmeter Hexagonal wrench Ammeter Gas Leak Detector Thermometer, Level Flaring Tool Set Service Manual 15
Installation Read carefully, and then follow step by step. Installation Parts Installation plate Type "B" screw Installation Type "A" screw and plastic anchor Remote Control Holder Installation Tools Figure Name Screw driver Electric Drill Measuring Tape, Knife Hole Core Drill Spanner Torque wrench Figure Name Ohmmeter Hexagonal wrench Ammeter Gas Leak Detector Thermometer, Level Flaring Tool Set Service Manual 15
Service Manual
Page 16
...) more than 70cm (27.6 inch) 16 Multi type Air Conditioner Do not have any heat or steam near a doorway. 5. Do not install near the unit. 2. Select a place so that the spaces indicated by arrows from the air conditioner do not disturb neighbors. niently routed away. 4....regarding rooftop mounting. Take the air conditioner weight into account and select a place where noise and vibration are adequate for the unit location. Installation Select the best location Indoor unit 1. Select a place where there are no obstacles in the path of the unit. 3. Make sure that...
...) more than 70cm (27.6 inch) 16 Multi type Air Conditioner Do not have any heat or steam near a doorway. 5. Do not install near the unit. 2. Select a place so that the spaces indicated by arrows from the air conditioner do not disturb neighbors. niently routed away. 4....regarding rooftop mounting. Take the air conditioner weight into account and select a place where noise and vibration are adequate for the unit location. Installation Select the best location Indoor unit 1. Select a place where there are no obstacles in the path of the unit. 3. Make sure that...
Service Manual
Page 17
Oil trap should be installed every 5~7 meters (16.4~23.0ft). Installation Piping length and elevation Multi Piping Type Capacity(Btu/h) Max total length of all pipes (A+B/A+B+C) Max length of each pipe (A/B/C) Min length of each pipe (A/B/C) ...
Oil trap should be installed every 5~7 meters (16.4~23.0ft). Installation Piping length and elevation Multi Piping Type Capacity(Btu/h) Max total length of all pipes (A+B/A+B+C) Max length of each pipe (A/B/C) Min length of each pipe (A/B/C) ...
Service Manual
Page 18
... Right rear piping 18 Multi type Air Conditioner Drilling the hole through the walls typically. Mount the installation plate on a concrete wall, use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the wall for piping connections must be strong... and solid enough to use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using a level. If mounting the unit on the wall with type "A" screws. Measure the wall and...
... Right rear piping 18 Multi type Air Conditioner Drilling the hole through the walls typically. Mount the installation plate on a concrete wall, use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the wall for piping connections must be strong... and solid enough to use anchor bolts. • Mount the installation plate horizontally by aligning the centerline using a level. If mounting the unit on the wall with type "A" screws. Measure the wall and...
Service Manual
Page 19
... drainage. 2. The moment of lifting the both lower parts of cover side. CAUTION: After removing the pipe hole, cut the burr for Installation (Artcool Type Only) Open panel front 1. Installation Preparing work for safety. Remove two screws(for fixing cover pipe) 2. Pull up to remove the two screws. 2. In case of desired...
... drainage. 2. The moment of lifting the both lower parts of cover side. CAUTION: After removing the pipe hole, cut the burr for Installation (Artcool Type Only) Open panel front 1. Installation Preparing work for safety. Remove two screws(for fixing cover pipe) 2. Pull up to remove the two screws. 2. In case of desired...
Service Manual
Page 20
.... Look at either the right or the left with plastic anchors, and fix completely the upper screws. Drill the piercing part for hanging product) 10mm INSTALLATION GU 9. First, Drive the two points of the upper parts by screws. (Leave 10mm for connecting pipe as diameter 50mm. (In case of product)... the lower parts after facing the hole of product with the hole slightly slanted to No. 5 on this time, Remove the map) (Falling attention) INSTALLATION GUIDE MAP Hanger hole (Rear side of piercing rear surface) 2. Drill the piping hole at suited horizon by adhesive tape. Put an...
.... Look at either the right or the left with plastic anchors, and fix completely the upper screws. Drill the piercing part for hanging product) 10mm INSTALLATION GU 9. First, Drive the two points of the upper parts by screws. (Leave 10mm for connecting pipe as diameter 50mm. (In case of product)... the lower parts after facing the hole of product with the hole slightly slanted to No. 5 on this time, Remove the map) (Falling attention) INSTALLATION GUIDE MAP Hanger hole (Rear side of piercing rear surface) 2. Drill the piping hole at suited horizon by adhesive tape. Put an...
Service Manual
Page 22
... polyethylene or equivalent is located at the uper side can cause drain pan to the indoor unit. • Make a small loop with the cable for installation through the piping hole. • Do not connect the cable to overflow inside the room, insulate the hose with the figure by ) and pull the...
... polyethylene or equivalent is located at the uper side can cause drain pan to the indoor unit. • Make a small loop with the cable for installation through the piping hole. • Do not connect the cable to overflow inside the room, insulate the hose with the figure by ) and pull the...
Service Manual
Page 23
...Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them with the upper edge of the unit against the installation plate until the hooks engage into the rear piping housing section. Align the center of the pipes and sufficiently tighten the flare nut by ...moving it left and right sides of the installation plate.) Ensure that there may be no gap. 2. Bundle the piping and drain hose together by wrapping them together with a wrench. ...
...Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them with the upper edge of the unit against the installation plate until the hooks engage into the rear piping housing section. Align the center of the pipes and sufficiently tighten the flare nut by ...moving it left and right sides of the installation plate.) Ensure that there may be no gap. 2. Bundle the piping and drain hose together by wrapping them together with a wrench. ...
Service Manual
Page 24
... position. 2. When extending the drain hose at the top of the pipes and sufficiently tighten the flare nut by hand. 2. Align the center of the installation plate. • Insert the spacer etc. Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Torque kg.m 1.8 4.2 3. Insert the piping, drain...into the indoor unit. • Don't connect the cable to the indoor unit. • Make a small loop with a wrench. Indoor unit installation • Hang the indoor unit from the wall. Tighten the flare nut with the cable for easy connection later. 4. Flaring Work and Connection of...
... position. 2. When extending the drain hose at the top of the pipes and sufficiently tighten the flare nut by hand. 2. Align the center of the installation plate. • Insert the spacer etc. Outside diameter mm inch Ø6.35 1/4 Ø9.52 3/8 Torque kg.m 1.8 4.2 3. Insert the piping, drain...into the indoor unit. • Don't connect the cable to the indoor unit. • Make a small loop with a wrench. Indoor unit installation • Hang the indoor unit from the wall. Tighten the flare nut with the cable for easy connection later. 4. Flaring Work and Connection of...
Service Manual
Page 25
...Drain hose Pipe Vinyl tape(narrow) Wrap with vinyl tape so that the hooks are properly seated on the installation plate by wrapping them together with vinyl tape(wide) Indoor unit installation 1. Press the lower left and right. 3. Bundle the piping and drain hose together by moving it left... and right sides of the unit against the installation plate until the hooks engage into the rear piping housing section. Flaring Work and Connection of the chassis. Piping for passage through piping ...
...Drain hose Pipe Vinyl tape(narrow) Wrap with vinyl tape so that the hooks are properly seated on the installation plate by wrapping them together with vinyl tape(wide) Indoor unit installation 1. Press the lower left and right. 3. Bundle the piping and drain hose together by moving it left... and right sides of the unit against the installation plate until the hooks engage into the rear piping housing section. Flaring Work and Connection of the chassis. Piping for passage through piping ...
Service Manual
Page 27
For left may cause damage to the tubing. Bad case • Following bending type from right to left piping. Flaring Work and Connection of clamp and unfold the tubing to downward slowly. Service Manual 27 Follow the instruction below. Good case • Press on the upper side of Piping Installation Information.
For left may cause damage to the tubing. Bad case • Following bending type from right to left piping. Flaring Work and Connection of clamp and unfold the tubing to downward slowly. Service Manual 27 Follow the instruction below. Good case • Press on the upper side of Piping Installation Information.
Service Manual
Page 30
... wires according to the wiring diagram. • Connect the wires firmly, so that the color of the wires of the Outdoor Unit control cover. When installing, refer to change without notice. Connecting the Cable between Indoor Unit and Outdoor Unit Connecting the Cable between power source and the outdoor unit as...
... wires according to the wiring diagram. • Connect the wires firmly, so that the color of the wires of the Outdoor Unit control cover. When installing, refer to change without notice. Connecting the Cable between Indoor Unit and Outdoor Unit Connecting the Cable between power source and the outdoor unit as...
Service Manual
Page 35
...the pipings with gum type sealer. Secure the taped piping along the exterior wall using saddle or equivalent. In cases where the Outdoor unit is installed above the ground. Form a trap to up . 2. Trap Trap Service Manual 35 In cases where the outdoor unit is required to up ...sealer. Secure the tapped piping along the exterior wall. Taping Drain hose Plastic band Pipings Connecting cable Power supply cord • Trap is installed below the indoor unit perform the following . 1. Fix the piping onto the wall by wrapping the connecting portion of the indoor unit ...
...the pipings with gum type sealer. Secure the taped piping along the exterior wall using saddle or equivalent. In cases where the Outdoor unit is installed above the ground. Form a trap to up . 2. Trap Trap Service Manual 35 In cases where the outdoor unit is required to up ...sealer. Secure the tapped piping along the exterior wall. Taping Drain hose Plastic band Pipings Connecting cable Power supply cord • Trap is installed below the indoor unit perform the following . 1. Fix the piping onto the wall by wrapping the connecting portion of the indoor unit ...