User Manual
Page 3
...circuit different from that may cause undesired operation. may cause harmful interference to radio communications. This equipment generates, uses, and can be shielded cables, in a particular installation. However, there is subject to the following measures: • Reorient or relocate the receiving antenna. • ... frequency energy and, if not installed and used in accordance with FCC Rules and Regulations, cables connected to this device that interference will not occur in which the cable shield wire(s) have been grounded (tied) to the connector shell. Caution: Any changes or...
...circuit different from that may cause undesired operation. may cause harmful interference to radio communications. This equipment generates, uses, and can be shielded cables, in a particular installation. However, there is subject to the following measures: • Reorient or relocate the receiving antenna. • ... frequency energy and, if not installed and used in accordance with FCC Rules and Regulations, cables connected to this device that interference will not occur in which the cable shield wire(s) have been grounded (tied) to the connector shell. Caution: Any changes or...
User Manual
Page 13
Customer Support Product Service and Repair 14-1 Online Product Service and Repair Assistance 14-2 Technical Assistance 14-2 Online Technical Assistance 14-3 Limited Warranty 14-3 Appendix A - Appendix A Symbology Chart A-1 ASCII Conversion Chart (Code Page 1252 A-2 Code Page Mapping of Printed Bar Codes A-4 vii Maintenance 13-1 Cleaning the Scanner's Window 13-1 Inspecting Cords and Connectors 13-1 Replacing the Interface Cable 13-2 Troubleshooting 13-2 Chapter 14 -
Customer Support Product Service and Repair 14-1 Online Product Service and Repair Assistance 14-2 Technical Assistance 14-2 Online Technical Assistance 14-3 Limited Warranty 14-3 Appendix A - Appendix A Symbology Chart A-1 ASCII Conversion Chart (Code Page 1252 A-2 Code Page Mapping of Printed Bar Codes A-4 vii Maintenance 13-1 Cleaning the Scanner's Window 13-1 Inspecting Cords and Connectors 13-1 Replacing the Interface Cable 13-2 Troubleshooting 13-2 Chapter 14 -
User Manual
Page 16
... the Imager with USB Note: Hand Held Products recommends connecting the imager end of the following codes to program the 3800g. Connect the appropriate interface cable to the imager and to the Hand Held Products "USB Application Note," available at www.handheld.com. For additional USB programming and technical information, refer... the USB port of this is your interface and you want to change to a USB Keyboard (PC) or USB Keyboard (Mac), scan one of the cable first and the host end second.
... the Imager with USB Note: Hand Held Products recommends connecting the imager end of the following codes to program the 3800g. Connect the appropriate interface cable to the imager and to the Hand Held Products "USB Application Note," available at www.handheld.com. For additional USB programming and technical information, refer... the USB port of this is your interface and you want to change to a USB Keyboard (PC) or USB Keyboard (Mac), scan one of the cable first and the host end second.
User Manual
Page 19
Connect the appropriate interface cable to the imager and to a USB connection. Note: You will not hear a power-up beep because the 3800g is an example of the 3800g as a "... PC AT with CR suffix bar code on . Keyboard Wedge Connection Scanning the bar code below allows operation of a keyboard wedge connection: 1. Disconnect the keyboard cable from the Sample Symbols in the back of the terminal/computer. 3.
Connect the appropriate interface cable to the imager and to a USB connection. Note: You will not hear a power-up beep because the 3800g is an example of the 3800g as a "... PC AT with CR suffix bar code on . Keyboard Wedge Connection Scanning the bar code below allows operation of a keyboard wedge connection: 1. Disconnect the keyboard cable from the Sample Symbols in the back of the terminal/computer. 3.
User Manual
Page 20
If you programmed the imager for a different terminal interface and you must have the correct cable for your computer. The following bar code also programs a carriage return (CR) suffix. Connect the appropriate interface cable to an IBM PC AT and compatibles keyboard wedge interface, scan the bar code below. Turn off power to...
If you programmed the imager for a different terminal interface and you must have the correct cable for your computer. The following bar code also programs a carriage return (CR) suffix. Connect the appropriate interface cable to an IBM PC AT and compatibles keyboard wedge interface, scan the bar code below. Turn off power to...
User Manual
Page 57
6 Secondary Interface By switching secondary interface cables, the 3800g imager, for example, can communicate with a portable data terminal (secondary interface) in the imager's memory by scanning the Disable bar code below for ... 6 - 1 Default =Disable. * Disable Enable Secondary RS-232 Connection All communication parameters between the imager and terminal must match for the 3800g. 3800g Models Models 3800G04E, 3800G14E 3800G05E, 3800G15E Primary Interfaces TTL level RS-232, USB, Keyboard wedge TTL level RS-232, IBM Retail, USB, Retail USB, Keyboard wedge Secondary Interfaces TTL...
6 Secondary Interface By switching secondary interface cables, the 3800g imager, for example, can communicate with a portable data terminal (secondary interface) in the imager's memory by scanning the Disable bar code below for ... 6 - 1 Default =Disable. * Disable Enable Secondary RS-232 Connection All communication parameters between the imager and terminal must match for the 3800g. 3800g Models Models 3800G04E, 3800G14E 3800G05E, 3800G15E Primary Interfaces TTL level RS-232, USB, Keyboard wedge TTL level RS-232, IBM Retail, USB, Retail USB, Keyboard wedge Secondary Interfaces TTL...
User Manual
Page 105
... that a 2D Imager can be displayed in the Scan Data window. You can capture an image using a USB serial port emulation, only a USB cable is grouped into different categories. To communicate with the parameters' form belonging to scan bar codes and display the bar code data in the customized... loaded later to load in a window. When one available serial communication port, or a serial port emulation using the serial port and RS-232 cable, an external power supply is loaded with an imager, Visual Xpress requires that can be seen in an image window. Users in other locations can...
... that a 2D Imager can be displayed in the Scan Data window. You can capture an image using a USB serial port emulation, only a USB cable is grouped into different categories. To communicate with the parameters' form belonging to scan bar codes and display the bar code data in the customized... loaded later to load in a window. When one available serial communication port, or a serial port emulation using the serial port and RS-232 cable, an external power supply is loaded with an imager, Visual Xpress requires that can be seen in an image window. Users in other locations can...
User Manual
Page 125
Standard Cable Pinouts Keyboard Wedge 3800g User's Guide 10 Pin RJ41 Modular Plug connects to the imager handle 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input (Refer to tables on page 12-1) 8 Keyboard data 9 Keyboard clock 10 12 - 3
Standard Cable Pinouts Keyboard Wedge 3800g User's Guide 10 Pin RJ41 Modular Plug connects to the imager handle 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input (Refer to tables on page 12-1) 8 Keyboard data 9 Keyboard clock 10 12 - 3
User Manual
Page 126
Serial data to supply power for primary cable) 4 Supply ground 5 Receive data - Standard Cable Pinouts Serial Output 12 - 4 10 Pin RJ41 Modular Plug connects to the imager handle 1 2 Cord shield 3 Prog 1 (Tied to imager 6 Transmit data - Serial data from imager 7 Supply power input (Refer to tables on page 12-1) 8 Request to send data 9 Clear to send data 10 3800g User's Guide
Serial data to supply power for primary cable) 4 Supply ground 5 Receive data - Standard Cable Pinouts Serial Output 12 - 4 10 Pin RJ41 Modular Plug connects to the imager handle 1 2 Cord shield 3 Prog 1 (Tied to imager 6 Transmit data - Serial data from imager 7 Supply power input (Refer to tables on page 12-1) 8 Request to send data 9 Clear to send data 10 3800g User's Guide
User Manual
Page 127
12 - 5 3800g User's Guide connects to the imager handle 10 Pin Modular Plug 1 2 Data + 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data - Standard Cable Pinouts USB
12 - 5 3800g User's Guide connects to the imager handle 10 Pin Modular Plug 1 2 Data + 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data - Standard Cable Pinouts USB
User Manual
Page 129
Maintenance The 3800g provides reliable and efficient operation with scanner operation. solvents may scratch the window. A badly worn cable or damaged connector may interfere with a minimum of damage. Please see Customer Support on the imager's window - If the window is not... clean. Caution: Do not submerge the imager in water. Inspecting Cords and Connectors Inspect the scanner's interface cable and connector for wear or other signs of care. Cable replacement instructions are not to be cleaned the same way. ! Do not use solvents (e.g., acetone, benzene, ether, ...
Maintenance The 3800g provides reliable and efficient operation with scanner operation. solvents may scratch the window. A badly worn cable or damaged connector may interfere with a minimum of damage. Please see Customer Support on the imager's window - If the window is not... clean. Caution: Do not submerge the imager in water. Inspecting Cords and Connectors Inspect the scanner's interface cable and connector for wear or other signs of care. Cable replacement instructions are not to be cleaned the same way. ! Do not use solvents (e.g., acetone, benzene, ether, ...
User Manual
Page 130
...the side of a paper clip. 5. If the red aiming illumination line isn't illuminated, check that: • The cable is connected properly. • The host system power is the cable release. 4. This is on the paper clip, then remove the paper clip. 6. If your scanner is attached to ...the scanner with the new cable. Is the red aiming illumination line on ? Is the power on ? Replacing the Interface Cable The standard interface cable is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem...
...the side of a paper clip. 5. If the red aiming illumination line isn't illuminated, check that: • The cable is connected properly. • The host system power is the cable release. 4. This is on the paper clip, then remove the paper clip. 6. If your scanner is attached to ...the scanner with the new cable. Is the red aiming illumination line on ? Is the power on ? Replacing the Interface Cable The standard interface cable is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem...
User Manual
Page 136
... THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. Use of any provision is for five (5) years. 14 - 4 3800g User's Guide extends these warranties only to : cables, power supplies, cradles, and docking stations. Hand Held Products' RESPONSIBILITY AND PURCHASER'S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF...
... THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. Use of any provision is for five (5) years. 14 - 4 3800g User's Guide extends these warranties only to : cables, power supplies, cradles, and docking stations. Hand Held Products' RESPONSIBILITY AND PURCHASER'S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF...
Brochure
Page 1
...: Includes presentation scanning, global power choice options, and purpose built mounting solutions. • Intuitive User Feedback: Fully programmable options for retail connectivity. • Common Cabling: Uses same cable solutions as our linear, 2D, and Cordless imagers - Includes Visual Express™ software for Point of linear imagers. and all in a handheld linear reader...
...: Includes presentation scanning, global power choice options, and purpose built mounting solutions. • Intuitive User Feedback: Fully programmable options for retail connectivity. • Common Cabling: Uses same cable solutions as our linear, 2D, and Cordless imagers - Includes Visual Express™ software for Point of linear imagers. and all in a handheld linear reader...