HP Client Manager 6.1
Page 3
...are performed only on the client computers. After Microsoft Windows has booted on client computers. Normally, a SoftPaq would be configured to upgrade the BIOS firmware on the client computers, you specify. Software installations are returned from each client machine and installed separately. With HPCM..., such as the Storage Options or the Boot Order, as new or missing PCs, memory, battery, disk drives, CPUs, and monitors. HPCM will install the drivers only on your non-HP client computers. • Health monitoring: The health monitoring capabilities of the pre-configured reports...
...are performed only on the client computers. After Microsoft Windows has booted on client computers. Normally, a SoftPaq would be configured to upgrade the BIOS firmware on the client computers, you specify. Software installations are returned from each client machine and installed separately. With HPCM..., such as the Storage Options or the Boot Order, as new or missing PCs, memory, battery, disk drives, CPUs, and monitors. HPCM will install the drivers only on your non-HP client computers. • Health monitoring: The health monitoring capabilities of the pre-configured reports...
HP Workstations for Linux - User Guide
Page 46
...Base /c00910216 (x86_64) xw9400 may panic during install /c00910190 (x86) Installed kernel may report less memory than expected /c00910967 xw9300 or xw9400 may report time issue with Xen kernel /c00911010 Support for Fully...Linux 5 [x86_64] /c01742190 Linux Operating Systems using NVIDIA Graphics Driver Need to be Upgraded xw4600 xw6600 xw8600 xw9400 Z400 Z600 Z800 xw9400 xw9300 xw9400 xw4400 xw6400 xw8400 xw9400 xw4400 ...xw4400 xw6400 xw8400 xw4600 xw9400 xw4600 xw4600 xw9400 42 Appendix A Appendix-HP release notes for Red Hat Enterprise Linux Client 5 Use the following tables to determine...
...Base /c00910216 (x86_64) xw9400 may panic during install /c00910190 (x86) Installed kernel may report less memory than expected /c00910967 xw9300 or xw9400 may report time issue with Xen kernel /c00911010 Support for Fully...Linux 5 [x86_64] /c01742190 Linux Operating Systems using NVIDIA Graphics Driver Need to be Upgraded xw4600 xw6600 xw8600 xw9400 Z400 Z600 Z800 xw9400 xw9300 xw9400 xw4400 xw6400 xw8400 xw9400 xw4400 ...xw4400 xw6400 xw8400 xw4600 xw9400 xw4600 xw4600 xw9400 42 Appendix A Appendix-HP release notes for Red Hat Enterprise Linux Client 5 Use the following tables to determine...
Adaptec SCSI RAID 2120S: Installation Guide
Page 10
... Browser Edition. ■ Intelligent Hot Spares that component will be rebuilt automatically onto a Hot Spare. ■ Flash ROM for easy upgrades of controller firmware. ■ Event logging and event mail notification. ■ RAID Level migration wherein a RAID may be changed from connected... drives into a logical volume. ■ Cache memory with Error Correcting Code (ECC). ■ PCI Local Bus Specification, Revision 2.2, with the NTFS file system. Hot Spares may be assigned...
... Browser Edition. ■ Intelligent Hot Spares that component will be rebuilt automatically onto a Hot Spare. ■ Flash ROM for easy upgrades of controller firmware. ■ Event logging and event mail notification. ■ RAID Level migration wherein a RAID may be changed from connected... drives into a logical volume. ■ Cache memory with Error Correcting Code (ECC). ■ PCI Local Bus Specification, Revision 2.2, with the NTFS file system. Hot Spares may be assigned...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 4
... = 2 or CL = 2.5). If a second processor is 339100-xxx) or in pairs. ■ Do not mix DIMMs of the workstation or option boards. When adding, upgrading, or replacing PC2100 DDR SDRAM memory modules in the hp workstation xw6000, care must be completed prior to the documentation included in the same channel. DIMM Installation Guidelines IMPORTANT: This section...
... = 2 or CL = 2.5). If a second processor is 339100-xxx) or in pairs. ■ Do not mix DIMMs of the workstation or option boards. When adding, upgrading, or replacing PC2100 DDR SDRAM memory modules in the hp workstation xw6000, care must be completed prior to the documentation included in the same channel. DIMM Installation Guidelines IMPORTANT: This section...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 9
... Serial Number Location 1-10 Changing from a Minitower to a Desktop Configuration 1-10 Changing from a Desktop to a Minitower Configuration 1-14 2 Hardware Upgrades Installation Sequence 2-1 Removing the Workstation Access Panel 2-3 Removing the Front Bezel 2-4 Installing Additional Memory 2-5 DIMM Socket Locations 2-5 DIMM Installation Guidelines 2-6 DIMM Installation Configurations 2-7 Installing DIMMs 2-8 Removing DIMMs 2-8 Installing Additional Drives 2-9 Hardware Reference Guide...
... Serial Number Location 1-10 Changing from a Minitower to a Desktop Configuration 1-10 Changing from a Desktop to a Minitower Configuration 1-14 2 Hardware Upgrades Installation Sequence 2-1 Removing the Workstation Access Panel 2-3 Removing the Front Bezel 2-4 Installing Additional Memory 2-5 DIMM Socket Locations 2-5 DIMM Installation Guidelines 2-6 DIMM Installation Configurations 2-7 Installing DIMMs 2-8 Removing DIMMs 2-8 Installing Additional Drives 2-9 Hardware Reference Guide...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 29
2 Hardware Upgrades This chapter explains how to cool before touching them. Å WARNING: To reduce the risk of any optional hardware or third-party devices that were not included with your workstation. Installation Sequence Follow this sequence of steps to ensure the ...Memory ■ Drives ■ Expansion boards ■ Processors ✎ Finish the setup procedures for the preinstalled software before you begin, observe the following precautions. Å WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to remove the workstation...
2 Hardware Upgrades This chapter explains how to cool before touching them. Å WARNING: To reduce the risk of any optional hardware or third-party devices that were not included with your workstation. Installation Sequence Follow this sequence of steps to ensure the ...Memory ■ Drives ■ Expansion boards ■ Processors ✎ Finish the setup procedures for the preinstalled software before you begin, observe the following precautions. Å WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to remove the workstation...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 30
...Removing the Front Bezel" in this chapter. 4. Shut down the operating system properly, then turn off the workstation and any optional equipment, such as memory, additional drives, expansion boards, processors, or batteries. Install any external devices. See the appropriate sections in... installed. 10. See "Removing the Workstation Access Panel" in this chapter or the appendixes for instructions. 5. Turn on the monitor, workstation, and any external devices you are discharged of the workstation or optional equipment. Hardware Upgrades Ä CAUTION: Static electricity can damage...
...Removing the Front Bezel" in this chapter. 4. Shut down the operating system properly, then turn off the workstation and any optional equipment, such as memory, additional drives, expansion boards, processors, or batteries. Install any external devices. See the appropriate sections in... installed. 10. See "Removing the Workstation Access Panel" in this chapter or the appendixes for instructions. 5. Turn on the monitor, workstation, and any external devices you are discharged of the workstation or optional equipment. Hardware Upgrades Ä CAUTION: Static electricity can damage...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 33
... higher capacity DIMMs. You can be required to the following figure for dual channel operation. Hardware Upgrades Installing Additional Memory Your workstation comes with two preinstalled memory modules. DIMM socket locations Hardware Reference Guide 2-5 DIMM Socket Locations Your workstation supports a total of four DIMM sockets on channel B). DIMMs must be installed in the two unpopulated...
... higher capacity DIMMs. You can be required to the following figure for dual channel operation. Hardware Upgrades Installing Additional Memory Your workstation comes with two preinstalled memory modules. DIMM socket locations Hardware Reference Guide 2-5 DIMM Socket Locations Your workstation supports a total of four DIMM sockets on channel B). DIMMs must be installed in the two unpopulated...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 34
... DDR-SDRAM DIMMs. The DDR-SDRAM DIMMs must install two DIMMs of the workstation or option boards. DIMM temperatures can damage the electronic components of identical type and...2.5 (CL = 2 or CL = 2.5). Before beginning these guidelines: ■ When installing additional memory modules, you are locked in place. 2-6 Hardware Reference Guide When installing DIMMs, follow these procedures...arms are discharged of static electricity by briefly touching a grounded metal object. Hardware Upgrades DIMM Installation Guidelines Å WARNING: To reduce the risk of personal injury from...
... DDR-SDRAM DIMMs. The DDR-SDRAM DIMMs must install two DIMMs of the workstation or option boards. DIMM temperatures can damage the electronic components of identical type and...2.5 (CL = 2 or CL = 2.5). Before beginning these guidelines: ■ When installing additional memory modules, you are locked in place. 2-6 Hardware Reference Guide When installing DIMMs, follow these procedures...arms are discharged of static electricity by briefly touching a grounded metal object. Hardware Upgrades DIMM Installation Guidelines Å WARNING: To reduce the risk of personal injury from...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 35
...Hardware Upgrades ■ Install DIMMs in each channel for dual channel operation. For examples of DIMM for a fully populated system. DIMM Installation Configurations Possible Configuration 1 2 3 Memory ...Channel A DIMM Socket DIMM Socket XMM1 XMM3 DIMM DIMM DIMM DIMM Memory Channel B DIMM Socket DIMM Socket XMM2 XMM4 DIMM DIMM DIMM DIMM Identical pairs for quality and reliability. Ä CAUTION: Your workstation...and XMM3 and XMM4 must have been tested and approved by HP. Hardware Reference Guide 2-7 Performance will not function if the previous...
...Hardware Upgrades ■ Install DIMMs in each channel for dual channel operation. For examples of DIMM for a fully populated system. DIMM Installation Configurations Possible Configuration 1 2 3 Memory ...Channel A DIMM Socket DIMM Socket XMM1 XMM3 DIMM DIMM DIMM DIMM Memory Channel B DIMM Socket DIMM Socket XMM2 XMM4 DIMM DIMM DIMM DIMM Identical pairs for quality and reliability. Ä CAUTION: Your workstation...and XMM3 and XMM4 must have been tested and approved by HP. Hardware Reference Guide 2-7 Performance will not function if the previous...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 36
... the following illustrations to follow the correct configuration guidelines or your system will not function. 4. Remove the workstation access panel. 3. Locate the DIMM sockets. Ä CAUTION: Be sure to install memory modules. Installing a DIMM 5. Hardware Upgrades Installing DIMMs To install a DIMM: 1. Reassemble the workstation. Shut down the operating system properly, then turn off the...
... the following illustrations to follow the correct configuration guidelines or your system will not function. 4. Remove the workstation access panel. 3. Locate the DIMM sockets. Ä CAUTION: Be sure to install memory modules. Installing a DIMM 5. Hardware Upgrades Installing DIMMs To install a DIMM: 1. Reassemble the workstation. Shut down the operating system properly, then turn off the...
hp workstations xw6000 - hardware reference guide (301155-001), Second Edition
Page 82
...grounding methods E-2 guide screws 2-14 H hard drive adapter 2-16 installing 2-14, 2-16 removing 2-19 hardware screws 2-14 hardware upgrade kit, processor 2-31 headphone connector 1-3 heatsink/processor cool-down 2-31 removal 2-34 separating 2-31 warm-up 2-32 I installation ...15, 2-16 drive adapter 2-17 expansion board 2-22, 2-23 heatsink 2-28 memory 2-5 processor 2-25 Index-2 K keyboard connector 1-3 functions 1-7 Windows Logo Key 1-9 L line-out audio connector 1-3 M memory installation sequence 2-2 installing DIMMs 2-7 removing 2-8 microphone connector 1-3 minitower configuration changing ...
...grounding methods E-2 guide screws 2-14 H hard drive adapter 2-16 installing 2-14, 2-16 removing 2-19 hardware screws 2-14 hardware upgrade kit, processor 2-31 headphone connector 1-3 heatsink/processor cool-down 2-31 removal 2-34 separating 2-31 warm-up 2-32 I installation ...15, 2-16 drive adapter 2-17 expansion board 2-22, 2-23 heatsink 2-28 memory 2-5 processor 2-25 Index-2 K keyboard connector 1-3 functions 1-7 Windows Logo Key 1-9 L line-out audio connector 1-3 M memory installation sequence 2-2 installing DIMMs 2-7 removing 2-8 microphone connector 1-3 minitower configuration changing ...