Installation Instructions
Page 1
... and Table 1 describes them. SuperBus® 2000 4-Relay Output Module 1 Examples of the fire/security panel hardwire input zones. SuperBus 2000 vs. Module Circuit Board Components SuperBus 2000 panels have the ability to provide tamper protection. BUS LED (Red) Flashes to one of module uses include: u Turning on exit lights during a burglary alarm. Power for manually setting module unit Switches number (SuperBus panels). Simply connect a UL listed reed...
... and Table 1 describes them. SuperBus® 2000 4-Relay Output Module 1 Examples of the fire/security panel hardwire input zones. SuperBus 2000 vs. Module Circuit Board Components SuperBus 2000 panels have the ability to provide tamper protection. BUS LED (Red) Flashes to one of module uses include: u Turning on exit lights during a burglary alarm. Power for manually setting module unit Switches number (SuperBus panels). Simply connect a UL listed reed...
Installation Instructions
Page 4
... panel Installation Instructions. 3. TO ZONE 1 INPUT DEVICE(S) TO PANEL SUPERBUS TERMINALS OR CONNECTOR (SEE TABLE) TO OUTPUT 4 DEVICE TO OUTPUT 3 DEVICE TO OUTPUT 2 DEVICE TO OUTPUT 1 DEVICE 1. Note For specific wiring details, see the device Installation Instructions. 4 SuperBus® 2000 4-Relay Output Module Wire multiple modules in "daisy-chain" fashion (in Figure 7 and Table 4. Installation Wiring Note A) Class 2, Class 3, and power-limited fire alarm...
... panel Installation Instructions. 3. TO ZONE 1 INPUT DEVICE(S) TO PANEL SUPERBUS TERMINALS OR CONNECTOR (SEE TABLE) TO OUTPUT 4 DEVICE TO OUTPUT 3 DEVICE TO OUTPUT 2 DEVICE TO OUTPUT 1 DEVICE 1. Note For specific wiring details, see the device Installation Instructions. 4 SuperBus® 2000 4-Relay Output Module Wire multiple modules in "daisy-chain" fashion (in Figure 7 and Table 4. Installation Wiring Note A) Class 2, Class 3, and power-limited fire alarm...
Installation Instructions
Page 5
...AND CURRENT RATINGS ** DO NOT EXCEED PANEL +12V POWER CONSUMPTION LIMITS (SEE PANEL INSTALLATION INSTRUCTIONS) Figure 8. Module Zone Input Wiring Installing a Cover Tamper Switch If you must be dedicated to the module zone input. ZONE COM ZONE 1 GND +12 VDC NO 4 COM...alarm. MAGNET TO ANY ZONE INPUT MAGNET CLIP REED SWITCH 2.0K OHM EOL RESISTOR (49-467) 9712G12A.DSF Figure 10. Zone Input Wire Runs Gauge Max. Installing the Reed Switch SuperBus® 2000 4-Relay Output Module 5 Module Typical Output Wiring Connecting Devices to the Zone Input Follow the maximum zone...
...AND CURRENT RATINGS ** DO NOT EXCEED PANEL +12V POWER CONSUMPTION LIMITS (SEE PANEL INSTALLATION INSTRUCTIONS) Figure 8. Module Zone Input Wiring Installing a Cover Tamper Switch If you must be dedicated to the module zone input. ZONE COM ZONE 1 GND +12 VDC NO 4 COM...alarm. MAGNET TO ANY ZONE INPUT MAGNET CLIP REED SWITCH 2.0K OHM EOL RESISTOR (49-467) 9712G12A.DSF Figure 10. Zone Input Wire Runs Gauge Max. Installing the Reed Switch SuperBus® 2000 4-Relay Output Module 5 Module Typical Output Wiring Connecting Devices to the Zone Input Follow the maximum zone...
Installation Instructions
Page 8
...60° C) under temporary conditions Maximum Humidity: 90% relative humidity, non-condensing Dimensions: 5.25" x 4.125" x 1.0" (L x W x D) Color: Belgian grey Case Material: High-impact ABS plastic Installation: On wall or in panel cabinet mounting Listings (for ancillary use only): UL 365 Police Station Connected Burglar Alarm...the separation between the equipment and receiver. SuperBus® 2000 4-Relay Output Module Relay contacts rated 4A @ 24VDC, 4A... One supervised, fire-rated, hardwire zone Outputs: Four, panel programmable outputs with the instruction manual, may cause...
...60° C) under temporary conditions Maximum Humidity: 90% relative humidity, non-condensing Dimensions: 5.25" x 4.125" x 1.0" (L x W x D) Color: Belgian grey Case Material: High-impact ABS plastic Installation: On wall or in panel cabinet mounting Listings (for ancillary use only): UL 365 Police Station Connected Burglar Alarm...the separation between the equipment and receiver. SuperBus® 2000 4-Relay Output Module Relay contacts rated 4A @ 24VDC, 4A... One supervised, fire-rated, hardwire zone Outputs: Four, panel programmable outputs with the instruction manual, may cause...