Manual/User Guide
Page 5
... This section gives the meanings of the systems in this manual. CHAPTER 5 Interface This chapter describes the interface specifications of the MHT Series, 2.5-inch hard disk drives. Preface This manual describes MHT2080AT/ MHT2060AT/ MHT2040AT/ MHT2030AT/ MHT2020AT models of the disk drive. CHAPTER 4 Theory of Device Operation This chapter describes the operation theory of the disk...
... This section gives the meanings of the systems in this manual. CHAPTER 5 Interface This chapter describes the interface specifications of the MHT Series, 2.5-inch hard disk drives. Preface This manual describes MHT2080AT/ MHT2060AT/ MHT2040AT/ MHT2030AT/ MHT2020AT models of the disk drive. CHAPTER 4 Theory of Device Operation This chapter describes the operation theory of the disk...
Manual/User Guide
Page 14
Contents CHAPTER 3 Installation Conditions 3-1 3.1 Dimensions 3-2 3.2 Mounting 3-3 3.3 Cable Connections 3-9 3.3.1 Device connector 3-9 3.3.2 Cable connector specifications 3-10 3.3.3 Device connection 3-10 3.3.4 Power supply connector (CN1 3-11 3.4 Jumper Settings 3-11 3.4.1 Location of setting jumpers 3-11 3.4.2 Factory default setting 3-12 3.4.3 Master drive-slave drive setting 3-12 3.4.4 CSEL setting 3-13 3.4.5 Power Up in Standby setting 3-14 CHAPTER 4 Theory of Device Operation...
Contents CHAPTER 3 Installation Conditions 3-1 3.1 Dimensions 3-2 3.2 Mounting 3-3 3.3 Cable Connections 3-9 3.3.1 Device connector 3-9 3.3.2 Cable connector specifications 3-10 3.3.3 Device connection 3-10 3.3.4 Power supply connector (CN1 3-11 3.4 Jumper Settings 3-11 3.4.1 Location of setting jumpers 3-11 3.4.2 Factory default setting 3-12 3.4.3 Master drive-slave drive setting 3-12 3.4.4 CSEL setting 3-13 3.4.5 Power Up in Standby setting 3-14 CHAPTER 4 Theory of Device Operation...
Manual/User Guide
Page 20
... of model names and product numbers 1-5 Current and power dissipation 1-7 Environmental specifications 1-8 Acoustic noise specification 1-9 Shock and vibration specification 1-9 Table 3.1 Surface temperature measurement points and standard values..........3-6 Table 3.2 Cable connector specifications 3-10 Table 5.1 Signal assignment on the interface connector 5-3 Table 5.2 I/O registers 5-7 Table 5.3 Command code and parameters 5-15 Table 5.4 Information to be read by IDENTIFY...
... of model names and product numbers 1-5 Current and power dissipation 1-7 Environmental specifications 1-8 Acoustic noise specification 1-9 Shock and vibration specification 1-9 Table 3.1 Surface temperature measurement points and standard values..........3-6 Table 3.2 Cable connector specifications 3-10 Table 5.1 Signal assignment on the interface connector 5-3 Table 5.2 I/O registers 5-7 Table 5.3 Command code and parameters 5-15 Table 5.4 Information to be read by IDENTIFY...
Manual/User Guide
Page 21
The disk drive is 2.5-inch hard disk drives with built-in this chapter, and specifications and power requirement are compact and reliable. C141-E192-02EN 1-1 These disk drives use the AT-bus hard disk interface protocol and are described. CHAPTER 1 Device Overview 1.1 Features 1.2 Device Specifications 1.3 Power Requirements 1.4 Environmental Specifications 1.5 Acoustic Noise 1.6 Shock and Vibration 1.7 Reliability 1.8 Error Rate 1.9 Media Defects 1.10 Load/Unload Function 1.11 Advanced Power Management Overview and features are described in disk controllers.
The disk drive is 2.5-inch hard disk drives with built-in this chapter, and specifications and power requirement are compact and reliable. C141-E192-02EN 1-1 These disk drives use the AT-bus hard disk interface protocol and are described. CHAPTER 1 Device Overview 1.1 Features 1.2 Device Specifications 1.3 Power Requirements 1.4 Environmental Specifications 1.5 Acoustic Noise 1.6 Shock and Vibration 1.7 Reliability 1.8 Error Rate 1.9 Media Defects 1.10 Load/Unload Function 1.11 Advanced Power Management Overview and features are described in disk controllers.
Manual/User Guide
Page 24
...) • Average • Maximum (Full) 80 GB 60 GB 40 GB 30 GB 156,301,488 117,210,240 78,140,160 58,605,120 512 4,200 rpm ± 1% 7.14 ms 1.5 ms (typ.) Read: 12ms (typ.) 22 ms (typ.) 20 GB 39,070,080 Start time Interface Data Transfer Rate ...8226; To/From Media • To/From Host 3.5 sec (typ.) ATA-6 (Max. Table 1.1 Specifications (1/2) MHT2080AT MHT2060AT MHT2040AT MHT2030AT MHT2020AT Format Capacity (*1) Number of the disk drives. Cable length: 18inches (0.46 m)) (equipped with...
...) • Average • Maximum (Full) 80 GB 60 GB 40 GB 30 GB 156,301,488 117,210,240 78,140,160 58,605,120 512 4,200 rpm ± 1% 7.14 ms 1.5 ms (typ.) Read: 12ms (typ.) 22 ms (typ.) 20 GB 39,070,080 Start time Interface Data Transfer Rate ...8226; To/From Media • To/From Host 3.5 sec (typ.) ATA-6 (Max. Table 1.1 Specifications (1/2) MHT2080AT MHT2060AT MHT2040AT MHT2030AT MHT2020AT Format Capacity (*1) Number of the disk drives. Cable length: 18inches (0.46 m)) (equipped with...
Manual/User Guide
Page 25
... must be the same as listed in Table 1.2 since some models have been customized and have specifications that of model names and product numbers Model Name MHT2080AT MHT2060AT MHT2040AT MHT2030AT MHT2020AT Capacity (user area) 80 GB 60 GB 40 GB 30 GB 20 GB Mounting screw Order No. Table 1.2 Examples of the drive being replaced. Table 1.1 Specifications (2/2) Model Capacity (*1) No.
... must be the same as listed in Table 1.2 since some models have been customized and have specifications that of model names and product numbers Model Name MHT2080AT MHT2060AT MHT2040AT MHT2030AT MHT2020AT Capacity (user area) 80 GB 60 GB 40 GB 30 GB 20 GB Mounting screw Order No. Table 1.2 Examples of the drive being replaced. Table 1.1 Specifications (2/2) Model Capacity (*1) No.
Manual/User Guide
Page 28
...; Thermal Gradient Humidity • Operating • Non-operating • Maximum Wet Bulb Altitude (relative to sea level) • Operating • Non-operating Specification 5 °C to 55 °C (ambient) 5 °C to 60 °C (disk enclosure surface) -40 °C to 65 °C 20 ...176;C (Non-operating) -300 to 3,000 m -300 to be concerned with the power on /off sequence. 1.4 Environmental Specifications Table 1.4 lists the environmental specifications. The circuits do not allow a write signal if either voltage is turned on (6) Power on /off sequence The voltage detector ...
...; Thermal Gradient Humidity • Operating • Non-operating • Maximum Wet Bulb Altitude (relative to sea level) • Operating • Non-operating Specification 5 °C to 55 °C (ambient) 5 °C to 60 °C (disk enclosure surface) -40 °C to 65 °C 20 ...176;C (Non-operating) -300 to 3,000 m -300 to be concerned with the power on /off sequence. 1.4 Environmental Specifications Table 1.4 lists the environmental specifications. The circuits do not allow a write signal if either voltage is turned on (6) Power on /off sequence The voltage detector ...
Manual/User Guide
Page 29
...Vibration (Swept sine, 1/4 octave per minute) • Operating • Non-operating Shock (half-sine pulse) • Operating • Non-operating Specification 5 to 500 Hz, 9.8m/s2 0-peak (1G 0-peak) (without non-recovered errors) 5 to 500 Hz, 49m/s2 0-peak (5G 0-...duration 1176 m/s2 0-peak (120G 0-peak) 11ms duration (no damage) C141-E192-02EN 1-9 Table 1.5 Acoustic noise specification Item • Idle mode (DRIVE READY) Sound Power Sound Pressure (at 0.3m) Specification (typical) 2.3B(A) 24.0dB(A) Note: Measure the noise from the cover top surface. 1.6 Shock and Vibration Table...
...Vibration (Swept sine, 1/4 octave per minute) • Operating • Non-operating Shock (half-sine pulse) • Operating • Non-operating Specification 5 to 500 Hz, 9.8m/s2 0-peak (1G 0-peak) (without non-recovered errors) 5 to 500 Hz, 49m/s2 0-peak (5G 0-...duration 1176 m/s2 0-peak (120G 0-peak) 11ms duration (no damage) C141-E192-02EN 1-9 Table 1.5 Acoustic noise specification Item • Idle mode (DRIVE READY) Sound Power Sound Pressure (at 0.3m) Specification (typical) 2.3B(A) 24.0dB(A) Note: Measure the noise from the cover top surface. 1.6 Shock and Vibration Table...
Manual/User Guide
Page 42
... to satisfy them, contact us. The mounting frame is zero. IMPORTANT Use M3 screw for the mounting screw and the screw length should satisfy the specification in Figure 3.3. The tightening torque must be 0.49N·m (5kgf·cm).
... to satisfy them, contact us. The mounting frame is zero. IMPORTANT Use M3 screw for the mounting screw and the screw length should satisfy the specification in Figure 3.3. The tightening torque must be 0.49N·m (5kgf·cm).
Manual/User Guide
Page 48
Table 3.2 Cable connector specifications ATA interface and power supply cable (44-pin type) Name Cable socket (44-pin type) Model 89361-144 Manufacturer FCI IMPORTANT For the host... the ribbon may cause crosstalk between signal lines. Host system ATA-cable Disk Drive #0 ATA-cable DC Power supply Power supply cable Disk Drive #1 Figure 3.9 Cable connections 3-10 C141-E192-02EN Installation Conditions 3.3.2 Cable connector specifications Table 3.2 lists the recommended specifications for cables carrying differential signals. 3.3.3 Device connection Figure 3.9 shows how to connect...
Table 3.2 Cable connector specifications ATA interface and power supply cable (44-pin type) Name Cable socket (44-pin type) Model 89361-144 Manufacturer FCI IMPORTANT For the host... the ribbon may cause crosstalk between signal lines. Host system ATA-cable Disk Drive #0 ATA-cable DC Power supply Power supply cable Disk Drive #1 Figure 3.9 Cable connections 3-10 C141-E192-02EN Installation Conditions 3.3.2 Cable connector specifications Table 3.2 lists the recommended specifications for cables carrying differential signals. 3.3.3 Device connection Figure 3.9 shows how to connect...
Manual/User Guide
Page 73
... accelerates. 4.7 Servo Control e) The MPU is waiting for one revolution at 4,200 rpm is 14.286 ms. Therefore, the MPU charges the charge pump for a specific period, the MPU resets the SVC and starts from the SVC, and waits till the rotational speed reaches 4,200 rpm. For example, when the actual...
... accelerates. 4.7 Servo Control e) The MPU is waiting for one revolution at 4,200 rpm is 14.286 ms. Therefore, the MPU charges the charge pump for a specific period, the MPU resets the SVC and starts from the SVC, and waits till the rotational speed reaches 4,200 rpm. For example, when the actual...
Manual/User Guide
Page 83
... abnormal. That is completed successfully. Bit 1: - Address Mark Not Found (AMNF). X'05': Reading the system area is posted. (3) Features register (X'1F1') The Features register provides specific feature to the error. However, when the host system selects the slave device, the diagnostic code of data to be transferred to enable or disable...
... abnormal. That is completed successfully. Bit 1: - Address Mark Not Found (AMNF). X'05': Reading the system area is posted. (3) Features register (X'1F1') The Features register provides specific feature to the error. However, when the host system selects the slave device, the diagnostic code of data to be transferred to enable or disable...
Manual/User Guide
Page 105
... device sets the BSY bit of Status register and saves the parameters. The parameters set the number of sectors per cylinder with only CHS mode specification. 5.3 Host Commands At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) 0 1 1 1 x x ...number of heads minus 1") per track and the maximum head number (maximum head number is posted. The device ignores the L bit specification and operates with this command. Then the device clears the BSY bit and generates an interrupt. Upon receipt of this command terminates ...
... device sets the BSY bit of Status register and saves the parameters. The parameters set the number of sectors per cylinder with only CHS mode specification. 5.3 Host Commands At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) 0 1 1 1 x x ...number of heads minus 1") per track and the maximum head number (maximum head number is posted. The device ignores the L bit specification and operates with this command. Then the device clears the BSY bit and generates an interrupt. Upon receipt of this command terminates ...
Manual/User Guide
Page 120
... which the power management level shifts is from Active Idle to Low Power Idle to the specified APM level when the drive does not receive any commands for the drive. The settings of the APM level revert to their default values (Mode-1) when power-on the APM level settings. ...The drive automatically shifts to power saving mode up to Standby. The Mode-2 level requires the longest shifting time, depending on or a hardware reset occurs for a specific time. APM Level Mode 0 Active Idle → Low Power Idle Mode 1...
... which the power management level shifts is from Active Idle to Low Power Idle to the specified APM level when the drive does not receive any commands for the drive. The settings of the APM level revert to their default values (Mode-1) when power-on the APM level settings. ...The drive automatically shifts to power saving mode up to Standby. The Mode-2 level requires the longest shifting time, depending on or a hardware reset occurs for a specific time. APM Level Mode 0 Active Idle → Low Power Idle Mode 1...
Manual/User Guide
Page 141
... issuing the command, the host must set to as attribute values. If the failure prediction function is enabled, the device collects and updates data on specific items. The values of device failures depending on the subcommand specified in order to predict device failures are not supported with the FR register set...
... issuing the command, the host must set to as attribute values. If the failure prediction function is enabled, the device collects and updates data on specific items. The values of device failures depending on the subcommand specified in order to predict device failures are not supported with the FR register set...
Manual/User Guide
Page 144
...to reference the CL and CH registers. The host can predict failures in the enabled (when the SC register specification ≠ 00h) or disabled (when the SC register specification = 00) state. Then the device compares the device attribute values with insurance failure threshold values. If 24 ... in the device by periodically issuing the SMART RETURN STATUS subcommand (FR register = DAh) to a medium. This setting is preserved whether the drive's power is nearing the end of 3) Features Resister X'DA' X'DB' Function SMART RETURN STATUS: When the device receives this case, the ...
...to reference the CL and CH registers. The host can predict failures in the enabled (when the SC register specification ≠ 00h) or disabled (when the SC register specification = 00) state. Then the device compares the device attribute values with insurance failure threshold values. If 24 ... in the device by periodically issuing the SMART RETURN STATUS subcommand (FR register = DAh) to a medium. This setting is preserved whether the drive's power is nearing the end of 3) Features Resister X'DA' X'DB' Function SMART RETURN STATUS: When the device receives this case, the ...
Manual/User Guide
Page 156
...the same. Interface Bit 0 1 2 3 4 5...15 Table 5.14 Selective self-test feature flags Description Vendor specific (unused) When set to one, perform off-line scan after selective test Vendor specific (unused) When set to one , off-line scan after selective test is pending. When set and releases ...the lock function. The device compares the user password or master password in Table 5.15 to the device. Issuing this command invalidates the user password, the master password is set. (30...
...the same. Interface Bit 0 1 2 3 4 5...15 Table 5.14 Selective self-test feature flags Description Vendor specific (unused) When set to one, perform off-line scan after selective test Vendor specific (unused) When set to one , off-line scan after selective test is pending. When set and releases ...the lock function. The device compares the user password or master password in Table 5.15 to the device. Issuing this command invalidates the user password, the master password is set. (30...
Manual/User Guide
Page 161
... password. Bits 1 to 7 Reserved Bit 8 Security level 0 = High 1 = Maximum Bits 9 to be set. The device determines the operation of the lock function according to the specifications of SECURITY SET PASSWORD data Word 0 1 to 16 17 18 to the device. 5.3 Host Commands At command completion (I-O register contents) 1F7h(ST) 1F6h(DH) 1F5h...
... password. Bits 1 to 7 Reserved Bit 8 Security level 0 = High 1 = Maximum Bits 9 to be set. The device determines the operation of the lock function according to the specifications of SECURITY SET PASSWORD data Word 0 1 to 16 17 18 to the device. 5.3 Host Commands At command completion (I-O register contents) 1F7h(ST) 1F6h(DH) 1F5h...
Manual/User Guide
Page 170
... of the new address space, an ID Not Found error occurs. Interface (39) SET MAX ADDRESS EXT (X'37'): Option (customizing) • Description This command limits specifications so that the highest address that is outside of the IDENTIFY DEVICE command response. If the SC register bit is 0 and the value volatile (VV...
... of the new address space, an ID Not Found error occurs. Interface (39) SET MAX ADDRESS EXT (X'37'): Option (customizing) • Description This command limits specifications so that the highest address that is outside of the IDENTIFY DEVICE command response. If the SC register bit is 0 and the value volatile (VV...
Manual/User Guide
Page 173
...(SC) P Sector count (15-8) 1F2h(SC) C Sector count (7-0) 1F1h(FR) P xx 1F1h(FR) C xx C: Current P: Previous At command completion (I/O registers contents to 10000h. The LBA specification is increased from 100h to be transferred by a single command is the extended command of the WRITE DMA command.
...(SC) P Sector count (15-8) 1F2h(SC) C Sector count (7-0) 1F1h(FR) P xx 1F1h(FR) C xx C: Current P: Previous At command completion (I/O registers contents to 10000h. The LBA specification is increased from 100h to be transferred by a single command is the extended command of the WRITE DMA command.