FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 7
... on the measurement surfaces result in potentials greater than 1 V between the thermocouples, use electrically insulated thermocouples. • When servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with the battery case. 3 Safety Information (cont.) WWarning (cont.) • Model 52: Measurement errors may damage the... into a fire. • Follow local laws or regulations when disposing of batteries. • Match the + and − polarities of the battery with any part of the case or cover removed. 51 & 52 Series II Introduction Table 1.
... on the measurement surfaces result in potentials greater than 1 V between the thermocouples, use electrically insulated thermocouples. • When servicing the thermometer, use only specified replacement parts. • Do not use the thermometer with the battery case. 3 Safety Information (cont.) WWarning (cont.) • Model 52: Measurement errors may damage the... into a fire. • Follow local laws or regulations when disposing of batteries. • Match the + and − polarities of the battery with any part of the case or cover removed. 51 & 52 Series II Introduction Table 1.
FE 51 & 52 II Users Manual
Page 17
...to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to the safety information in "Replacement Parts and Accessories." Loosen the screw and remove the battery door. 3. Replace the battery door and tighten the screw. To calibrate the thermometer...commercial cleaner. Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before...
...to 122 oF) Storage −40 oC to +60 oC Temperature (−40 oF to the safety information in "Replacement Parts and Accessories." Loosen the screw and remove the battery door. 3. Replace the battery door and tighten the screw. To calibrate the thermometer...commercial cleaner. Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before...
FE 51 & 52 II Users Manual
Page 19
The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual ...
The above specifications do not include thermocouple error. 51 & 52 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual ...