Popular Fluke 54 Manual Pages

Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet - Page 1

... allows compensation of thermocouple errors to maximize overall accuracy • Readout in °C, °F, or Kelvin (K) • Sleep mode increases battery life • Battery door allows easy battery replacement without breaking the calibration seal Additional features for the 53 and 54 Series II: • Data Logging up to 500 points of data with user adjustable recording interval...
FE 53 & 54 II Users Manual - Page 1

Printed in USA All product names are trademarks of their respective companies. ® 53 & 54 Series II Thermometer Users Manual September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
FE 53 & 54 II Users Manual - Page 4

... and Data Entries 16 Starting and Stopping Logging 16 Clearing Memory ...17 Viewing Logged Readings 17 Communicating with a PC 18 Maintenance...19 Replacing the Batteries 19 Cleaning the Case and Holster 19 Calibration ...19 Specifications ...19 Environmental...19 General...20 80 PK-1 Thermocouple (supplied with thermometer 20 Electrical...20 Replacement Parts and Accessories 21 ii
FE 53 & 54 II Users Manual - Page 5

... meter symbols in this manual. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-warranty.com 1 P.O. Refer to : Fluke Corporation P.O. 53 & 54 Series II Safety Information The Fluke Model 53 and Model 54 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed to use...
FE 53 & 54 II Users Manual - Page 6

... thermocouple(s) from the thermometer before opening the case. • Replace the batteries as soon as marked on the thermometer, between the thermocouple(s), or between any thermocouple and earth ground. 2 The possibility of false readings can lead to the user. Protection may be impaired. Do not use the thermometer if it appears damaged. 53 & 54 Series II Users Manual Table 1.
FE 53 & 54 II Users Manual - Page 8

...with the thermometer, study the following sections. 4 To become familiar with European Union directives. Complies with relevant Canadian Standards Association directives. Then read the following : • Figure 1 and Table 3 describe the components. • Figure 2 and Table 4 describe the display. • Table 5 describes the functions of the buttons. 53 & 54 Series II Users Manual Table...
FE 53 & 54 II Users Manual - Page 10

...are being logged. L Time Display: 24-hour clock. C A shift function is on or before clock has been set. I The temperature units. Model 54: T1 or T2 reading. See "Changing Setup Options." K The thermocouple type. 53 & 54 Series II Users Manual Display Elements 2 3 45 1 xx 6 7 12 11 Figure 2. Display Elements A The thermocouple measurement includes an offset. D Readings are...
FE 53 & 54 II Users Manual - Page 12

... a Setup option. Buttons (cont.) Press h to decrease the displayed setting. Press N to freeze or unfreeze the displayed readings. Press r to test the display. Press h when turning on the thermometer to show logged readings and MIN MAX readings on the display. Press K to store the displayed setting in the primary or secondary display. 53 & 54 Series II Users Manual...
FE 53 & 54 II Users Manual - Page 13

...plugged into the input connector(s). 2. Changing Setup Options Use Setup to change the logging interval, thermocouple type, offset, sleep mode, time, and line frequency settings. Press A to start or exit Setup. Setup settings reset only when the batteries are removed for more than 2 minutes. 53 & 54 Series II Using the Thermometer Entering and Exiting Setup When the thermometer is disabled...
FE 53 & 54 II Users Manual - Page 14

...set the logging interval manually (0). Each time you want appear on the display, and then press E to select. The left two digits blink. • Press K or N until the left two digits you press J, the thermometer... or user-defined (USef). See "Using Memory." 53 & 54 Series II Users Manual Changing the Logging Interval The logging interval determines how often the thermometer stores ...
FE 53 & 54 II Users Manual - Page 15

Model 54: You can adjust the thermometer's readings to store the offset setting in memory. 53 & 54 Series II Changing Setup Options Changing the Offset You can ... N until the display shows TYPE. 2. Remember to reset the offset to Adjust for the errors of a specific thermocouple. The allowable adjustment range is no longer needed. The offset automatically resets to display the...
FE 53 & 54 II Users Manual - Page 16

... set or shows 2. Press E to indicate you want to select. Press E to store the time in memory. 53 & 54 Series II Users Manual Enabling or Disabling Sleep Mode The thermometer enters...to its previous state. 1. Setting the Time 1. The left two digits blink. 3. The right two digits blink. 4. Pressing any button wakes the thermometer and returns it is set the time. Sleep mode is...
FE 53 & 54 II Users Manual - Page 20

... values by pressing r or using FlukeView Forms. The data entries are a time stamp, the T1 reading, and the T2 and T1-T2 readings (Model 54). The thermometer stores 499 sets of temperature readings and one set of initial conditions when logging individual points manually. Starting and Stopping Logging Setup, memory clear, and PC communications are the thermocouple type...
FE 53 & 54 II Users Manual - Page 23

... safety information in "Replacement Parts and Accessories." Turn off the thermometer if necessary. 2. Replace the three AA batteries. 4. Wipe with a damp sponge or soft rag. 53 & 54 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table...
FE 53 & 54 II Users Manual - Page 25

... to 200 MHz in 3 V/m field. The above specifications do not include thermocouple error. 53 & 54 Series II Replacement Parts and Accessories Replacement Parts and Accessories Accessory Part Number Holster and Flex Stand™ Assembly 1272438 AA NEDA 15A IEC LR6 batteries 376756 80PK-1 K-Type Bead Thermocouple 773135 CD-ROM 1276106 Service Manual 1276123 21 Electrical (cont...

Fluke 54 Reviews

Do you have an experience with the Fluke 54 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 54 Search Terms

The following terms are frequently used to search for Fluke 54 support:

Ask a New Question
Use the box below to post a new question about Fluke 54.
Manuals / Documents
Download any of our Fluke 54 manuals for free!

We have the following 2 documents available for the Fluke 54:
  • FE 53 & 54 II Users Manual
  • Fluke 51II, 52II, 53II, and 54II Thermometer Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 54 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 54 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.