Get support for Fluke 1520

Fluke 1520 Support Question

Fluke 1520 Support Question

Find answers below for this question about Fluke 1520.
Need a Fluke 1520 manual? We have 2 online manuals for this item!
Question posted by sr55blackbird on May 15th, 2016

Fluke Megohmmeter 1520 Parts

I believe my display is bad. The back light operates and continuity works but no digits light.DO you have replacement parts?THB

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 1520 Manual Pages

Fluke 1520 MegOhmMeter Datasheet - Page 1

... measures voltage and checks connections with its Lo-Ohms function. • Large, backlit LCD with analog bar graph and digital display • Three output voltages for up to 600V dc Fluke 1520 MegOhmMeter Technical Data The Fluke 1520 MegOhmMeter is greater than 30V ac or 30V dc. • AC/DC voltage measurement up to 600V • Lo-Ohms...
Fluke 1520 MegOhmMeter Datasheet - Page 2

...Weight 1.1 kg (2.5 lbs) Batteries 4 C size 1.5V alkaline Warranty 3 years Ordering Information Fluke 1520 MegOhmMeter Included AccessoriesFluke 1520 MegOhmMeter • TL27 Heavy Duty Test Leads (1 Red and 1 Black) • TP74 Lantern... III 600V Agency Approvals UL, CSA, VDE (pending) Environmental Specifications Operating Temperature -10°C to +50°C Storage Temperature -40°...
FE 1520 Users Manual - Page 1

Printed in USA All product names are trademarks of their respective companies. All rights reserved. ® 1520 MegOhmMeter Users Manual September 2000 Rev.2, 2/03 © 2000-2003 Fluke Corporation.
FE 1520 Users Manual - Page 6

... and black, 1.5 m • 2 test probes, red and black • 2 alligator clips, red and black • Hand strap • Carrying case • CD ROM (Not Pictured) 1 Fluke 1520 Unpacking the Meter The Fluke Model 1520 MegOhmMeter (hereafter, "the meter") is a handheld instrument designed primarily to make resistance/insulation resistance measurements.
FE 1520 Users Manual - Page 9

... by the equipment. Check test lead continuity. Do not use the Meter if it looks damaged. • Be careful when working alone. • Inspect the test leads for damaged insulation or exposed metal. Keep your fingers away from probe contacts. Fluke 1520 Users Manual W Safety Information Use of additional operating circuits connected in a manner not...
FE 1520 Users Manual - Page 11

...- this button until the main reading is stable. Fluke 1520 Users Manual Key functions Table 1. To lock: press and hold this mode continuously applies the test current to the circuit to be ... 6 The icon V LOCK appears on the display. • Insulation Resistance- The beeper sounds every 2 seconds to be tested. this mode continuously applies the test voltage to the circuit to remind...
FE 1520 Users Manual - Page 13

.... 3 Resistance reading held from the last measurement in Insulation Resistance or Low Resistance function. 4 Beeper symbol shows if beeper function is present on a linear scale. Fluke 1520 Users Manual Display Table 2 and Figure 2 describe the...
FE 1520 Users Manual - Page 15

Warning To prevent electric shock, first connect the test leads to the Meter inputs before you make connection to be measured. Warning To prevent electric shock when performing resistance tests, remove all W power from the circuit to the circuit under test. 10 Fluke 1520 Users Manual Using the Meter Connecting to the Circuit Under Test W Figure 3 shows the proper connections.
FE 1520 Users Manual - Page 17

... correctly wired and no personnel are endangered by any tests. 12 W Measuring Insulation Resistance Warning • Measuring insulation resistance requires the application of non-use . Fluke 1520 Users Manual Auto-Shut-Off The Meter automatically turns off after 15 minutes of potentially dangerous voltages to the desired function. In Lo Ohms mode...
FE 1520 Users Manual - Page 19

... main reading shows the decreasing voltage. The upper right display holds the resistance reading until the circuit is higher than the maximum display range, the meter reacts as the main display. While keeping the probes on the test points, release the TEST button. Fluke 1520 Users Manual The Meter beeps when the reading is selected...
FE 1520 Users Manual - Page 21

Fluke 1520 Users Manual Measuring Low Resistance To measure low resistance: 1. Zero out the test lead resistance (see Table 1). 2. W If voltage is displayed. acf06f.eps 3. The resistance shows on the probes, the voltage is present on the main display.... A single beep indicates a stable reading. The upper right display holds the resistance reading until a new test is started or ...
FE 1520 Users Manual - Page 23

... If the voltage being measured has both an ac and dc component, the Meter displays only the largest component of the measured signal. 18 acf07f.eps acf08f.eps Measure ...voltage is higher than 4000 Ω, >4000 Ω is displayed. Connect the probes to the circuit to be measured. Measuring Voltage 1. Fluke 1520 Users Manual Measuring Resistance 1. W 2. If the resistance is higher ...
FE 1520 Users Manual - Page 25

Remove any residue afterwards. Do not use abrasives or solvents. 20 Periodically wipe the case with soap and water. Fluke 1520 Users Manual Maintaining the Meter This section provides basic maintenance information, including fuse and battery replacement instructions. Cleaning Clean only with a damp cloth and mild detergent. Caution Do not attempt to repair or...
FE 1520 Users Manual - Page 27

Secure the battery access lid back in position with a flat-blade screwdriver. 5. Replace the C cells as shown in the battery compartment. 7. Lift the battery access lid away from the Meter. 6. Fluke 1520 Users Manual 4. Observe the battery polarity shown in Figure 5. Place the Meter face down on a nonabrasive surface and loosen the two screws with the two screws. 22
FE 1520 Users Manual - Page 29

... indicate approximately 0.5 Ω. Turn the rotary switch to the input terminals and short them together. If the display reads >40 Ω, replace the fuse as described in the "Replacement Parts and Optional Accessories" section. Fluke 1520 Users Manual W Testing and Replacing the Fuse Warning To avoid electric shock, disconnect the test leads from the inputs before opening the...
FE 1520 Users Manual - Page 31

Replacing the Fuse acf11f.eps 26 Fluke 1520 Users Manual Figure 6.
FE 1520 Users Manual - Page 32

...Number 423582 669058 803459 803467 803434 803442 603115 670643 669069 NA 1556096 Part Number 669074 669903 27 MegOhmMeter Replacement Parts and Optional Accessories Replacement Parts and Optional Accessories Replacement Part Battery 1.5 V Alkaline Size C Test Lead set Test Probe, 1 kV, lantern tip, red Test Probe, 1 kV, lantern tip, black Alligator Clip, red Alligator Clip, black Carrying ...
FE 1520 Users Manual - Page 33

Fluke 1520 Users Manual Principle of Measurement for Resistance The Meter measures resistance by performing the following calculation: R = V (Ohm's Law) I Service Centers To locate an authorized service center, visit us on the World Wide Web: www.fluke.com or call Fluke using any of the circuit. The resistance is then established by inducing a current in...
FE 1520 Users Manual - Page 37

Fluke 1520 Users Manual Test Voltages Accuracy Nominal Current Number of measurements Circuitry Protection Display Range Measurement Range Accuracy Resolution Analog Bar Graph Open Circuit Voltage Short Circuit Current Test Leads Zero Number of measurements Circuitry Protection 32 250 V, 500 V, ...
FE 1520 Users Manual - Page 39

... invoice Buyer for importation costs of repair/replacement parts when product purchased in accordance with a description of the difficulty, postage and insurance prepaid (FOB Destination), to end-user customers only but have no risk for 90 days. Fluke 1520 Users Manual Limited Warranty & Limitation of Liability Each Fluke product is warranted to be returned to...

Similar Questions

Fluke 1520 Megaohm Meter.
Can I replace the screen on my 1520 fluke meter. Fluke was dropped and screen is partially blak.
(Posted by elvensd 1 year ago)
Fluke T5 1000 Part
I need a battery cover for a fluke t5 1000.
(Posted by jdhas 2 years ago)
Battery
we have a 1550B megohmmeter but the battery does not hold a charge, how can we get a new battery for...
(Posted by lxblack 9 years ago)
Display
i need a new display for a 337. how much and can it be put in
(Posted by Zeb5019 9 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1520 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.