Product Manual
Page 1
Printed in China. All product names are subject to change without notice. 62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. All rights reserved. Specifications are trademarks of their respective companies.
Printed in China. All product names are subject to change without notice. 62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. All rights reserved. Specifications are trademarks of their respective companies.
Product Manual
Page 2
...fuses, disposable batteries, or damage from the date of operation or handling. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. Fluke Europe B.V. Box 1186 5602 BD Eindhoven The Netherlands LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free.... To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a...problem. THIS WARRANTY IS YOUR ONLY REMEDY. Resellers are not authorized to you. ...
...fuses, disposable batteries, or damage from the date of operation or handling. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. Fluke Europe B.V. Box 1186 5602 BD Eindhoven The Netherlands LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free.... To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a...problem. THIS WARRANTY IS YOUR ONLY REMEDY. Resellers are not authorized to you. ...
Product Manual
Page 3
Table of Contents Title Page Introduction ...1 How to Contact Fluke 1 Safety Information ...2 Maintenance ...6 How to Change the Battery 6 How to Clean the Product 6 Specifications ...7 Standards and Agency Approval 9 The Product ...10 i
Table of Contents Title Page Introduction ...1 How to Contact Fluke 1 Safety Information ...2 Maintenance ...6 How to Change the Battery 6 How to Clean the Product 6 Specifications ...7 Standards and Agency Approval 9 The Product ...10 i
Product Manual
Page 5
...The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800... Anywhere in the world: +1-425-446-5500 1 Note that the Japanese models indicate Celsius only. Warning Read all safety information before you use the Product. How to Contact Fluke To contact Fluke, call one of infrared energy radiated by the target's surface.
...The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800... Anywhere in the world: +1-425-446-5500 1 Note that the Japanese models indicate Celsius only. Warning Read all safety information before you use the Product. How to Contact Fluke To contact Fluke, call one of infrared energy radiated by the target's surface.
Product Manual
Page 6
... supplied by the Product can cause damage to the user. Look for cracks or missing plastic. 2 To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that can be compromised. • Before you use the Product if it appears damaged. 62 MAX/62 MAX + Users Manual Or, visit Fluke's website at www.fluke...
... supplied by the Product can cause damage to the user. Look for cracks or missing plastic. 2 To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. Safety Information A Warning identifies conditions and procedures that can be compromised. • Before you use the Product if it appears damaged. 62 MAX/62 MAX + Users Manual Or, visit Fluke's website at www.fluke...
Product Manual
Page 7
... actual temperature measurements. Do not point laser directly at persons or animals or indirectly off reflective surfaces. • Replace the batteries when the low battery indicator shows to the eye. • Do not look directly into the laser. Reflective objects result in damp or wet environments. • Use the Product only as specified or hazardous laser...
... actual temperature measurements. Do not point laser directly at persons or animals or indirectly off reflective surfaces. • Replace the batteries when the low battery indicator shows to the eye. • Do not look directly into the laser. Reflective objects result in damp or wet environments. • Use the Product only as specified or hazardous laser...
Product Manual
Page 8
... reference to Fluke's website for recycling information. 4 Do not dispose of danger. The affixed label indicates that you must not discard this electrical/electronic product in the WEEE Directive Annex I, this product as category 9 "Monitoring and Control Instrumentation" product. 62 MAX/62 MAX + Users Manual Symbol Table 1. Important information. This product complies with the WEEE Directive (2002/96/EC) marking...
... reference to Fluke's website for recycling information. 4 Do not dispose of danger. The affixed label indicates that you must not discard this electrical/electronic product in the WEEE Directive Annex I, this product as category 9 "Monitoring and Control Instrumentation" product. 62 MAX/62 MAX + Users Manual Symbol Table 1. Important information. This product complies with the WEEE Directive (2002/96/EC) marking...
Product Manual
Page 9
Laser. Conforms to China Metrology Certification 5 Conforms to European Union directives. Battery Conforms to relevant Australian standards. Symbols (cont.) Meaning Symbol Meaning Warning. Symbol Infrared Thermometer Safety Information Table 1.
Laser. Conforms to China Metrology Certification 5 Conforms to European Union directives. Battery Conforms to relevant Australian standards. Symbols (cont.) Meaning Symbol Meaning Warning. Symbol Infrared Thermometer Safety Information Table 1.
Product Manual
Page 10
How to Clean the Product Use soap and water on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. The swab may be moistened with a moist cotton swab. See Figure 17. 6 Carefully wipe the surface with water. 62 MAX/62 MAX + Users Manual Maintenance Caution To avoid damage to the Product, do not leave the thermometer on a damp sponge or soft cloth to clean the Product case.
How to Clean the Product Use soap and water on or near objects of high temperature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16. The swab may be moistened with a moist cotton swab. See Figure 17. 6 Carefully wipe the surface with water. 62 MAX/62 MAX + Users Manual Maintenance Caution To avoid damage to the Product, do not leave the thermometer on a damp sponge or soft cloth to clean the Product case.
Product Manual
Page 11
Infrared Thermometer Specifications Specifications Temperature Range Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) Response Time (95 %) Spectral Response Emissivity Temperature Coefficient 62 MAX 62 MAX + -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F) ≥0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater (≥32 °F: ±3 °F or ±1.5 % of reading, whichever is greater) ≥ -10 °C to
Infrared Thermometer Specifications Specifications Temperature Range Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) Response Time (95 %) Spectral Response Emissivity Temperature Coefficient 62 MAX 62 MAX + -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F) ≥0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater (≥32 °F: ±3 °F or ±1.5 % of reading, whichever is greater) ≥ -10 °C to
Product Manual
Page 12
62 MAX/62 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude 10:1 12:1 (calculated at 90 % energy) (calculated at 90 % energy) 0.1 °C (0.2 °F) ±0.8 % of reading or ±1.0 °C ±0.5 % of reading or ±0.5 °C (2 °F), whichever is greater (1 °F), whichever is greater 1 AA IEC LR06 Battery 10...
62 MAX/62 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude 10:1 12:1 (calculated at 90 % energy) (calculated at 90 % energy) 0.1 °C (0.2 °F) ±0.8 % of reading or ±1.0 °C ±0.5 % of reading or ±0.5 °C (2 °F), whichever is greater (1 °F), whichever is greater 1 AA IEC LR06 Battery 10...
Product Manual
Page 13
Infrared Thermometer Standards and Agency Approval Ingress Protection Rating Drop Test Vibration and Shock EMC IP 54 per IEC 60529 3 meters IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 ms EN 61326-1:2006 EN 61326-2:2006 Standards and Agency Approval Compliance EN/IEC 61010-1 Laser Safety EN 60825-1 Class 2 Implement Standard Q/SXAV37 9
Infrared Thermometer Standards and Agency Approval Ingress Protection Rating Drop Test Vibration and Shock EMC IP 54 per IEC 60529 3 meters IEC 60068-2-6 2.5 g, 10 to 200 Hz, IEC 60068-2-27, 50 g, 11 ms EN 61326-1:2006 EN 61326-2:2006 Standards and Agency Approval Compliance EN/IEC 61010-1 Laser Safety EN 60825-1 Class 2 Implement Standard Q/SXAV37 9
Product Manual
Page 18
62 MAX/62 MAX + Users Manual 12 38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm 13 33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm S 1.5" @ 2.4" @ 4" @ 12" 24" 36" D 62 MAX D:S = 10:1 S 1.4" @ 2" @ 12" 24" D 62 MAX + D:S = 12:1 3.4" @ 36" gtt08-11.eps 14
62 MAX/62 MAX + Users Manual 12 38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm 13 33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm S 1.5" @ 2.4" @ 4" @ 12" 24" 36" D 62 MAX D:S = 10:1 S 1.4" @ 2" @ 12" 24" D 62 MAX + D:S = 12:1 3.4" @ 36" gtt08-11.eps 14