Product Manual
Page 1
All rights reserved. All product names are subject to change without notice. Printed in China. 62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. Specifications are trademarks of their respective companies.
All rights reserved. All product names are subject to change without notice. Printed in China. 62 MAX/62 MAX + Infrared Thermometer Users Manual PN 4060712 April 2012 Rev. 1, 11/12 © 2012 Fluke Corporation. Specifications are trademarks of their respective companies.
Product Manual
Page 5
... infrared energy radiated by the target's surface. Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36...
... infrared energy radiated by the target's surface. Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36...
Product Manual
Page 6
...and personal injury: • Read all safety Information before you use the Product, inspect the case. To register your product, visit http://register.fluke.com. Do not use the Product if it appears damaged. A Caution identifies conditions and procedures that are dangerous to the Product or the equipment...operates incorrectly. • Use the Product only as specified, or the protection supplied by the Product can cause damage to the user. 62 MAX/62 MAX + Users Manual Or, visit Fluke's website at www.fluke.com. To see, print, or download the latest manual supplement, visit http://us...
...and personal injury: • Read all safety Information before you use the Product, inspect the case. To register your product, visit http://register.fluke.com. Do not use the Product if it appears damaged. A Caution identifies conditions and procedures that are dangerous to the Product or the equipment...operates incorrectly. • Use the Product only as specified, or the protection supplied by the Product can cause damage to the user. 62 MAX/62 MAX + Users Manual Or, visit Fluke's website at www.fluke.com. To see, print, or download the latest manual supplement, visit http://us...
Product Manual
Page 8
...: With reference to Fluke's website for recycling information. 4 Important information. The affixed label indicates that you must not discard this electrical/electronic product in the WEEE Directive Annex I, this product as category 9 "Monitoring and Control Instrumentation" product. Go to the equipment types in domestic household waste. 62 MAX/62 MAX + Users Manual Symbol ...
...: With reference to Fluke's website for recycling information. 4 Important information. The affixed label indicates that you must not discard this electrical/electronic product in the WEEE Directive Annex I, this product as category 9 "Monitoring and Control Instrumentation" product. Go to the equipment types in domestic household waste. 62 MAX/62 MAX + Users Manual Symbol ...
Product Manual
Page 10
How to Clean the Product Use soap and water on or near objects of high temperature. Carefully wipe the surface with water. The swab may be moistened with a moist cotton swab. How to clean the Product case. See Figure 17. 6 62 MAX/62 MAX + Users Manual Maintenance Caution To avoid damage to the Product, do not leave the thermometer on a damp sponge or soft cloth to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16.
How to Clean the Product Use soap and water on or near objects of high temperature. Carefully wipe the surface with water. The swab may be moistened with a moist cotton swab. How to clean the Product case. See Figure 17. 6 62 MAX/62 MAX + Users Manual Maintenance Caution To avoid damage to the Product, do not leave the thermometer on a damp sponge or soft cloth to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16.
Product Manual
Page 11
Infrared Thermometer Specifications Specifications Temperature Range Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) Response Time (95 %) Spectral Response Emissivity Temperature Coefficient 62 MAX 62 MAX + -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F) ≥0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater (≥32 °F: ±3 °F or ±1.5 % of reading, whichever is greater) ≥ -10 °C to
Infrared Thermometer Specifications Specifications Temperature Range Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) Response Time (95 %) Spectral Response Emissivity Temperature Coefficient 62 MAX 62 MAX + -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F) ≥0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater (≥32 °F: ±3 °F or ±1.5 % of reading, whichever is greater) ≥ -10 °C to
Product Manual
Page 12
62 MAX/62 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude 10:1 ...
62 MAX/62 MAX + Users Manual Optical Resolution Display Resolution Repeatability (% of reading) Power Battery Life Weight Size Operating Temperature Storage Temperature Operating Humidity Operating Altitude Storage Altitude 10:1 ...
Product Manual
Page 18
62 MAX/62 MAX + Users Manual 12 38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm 13 33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm S 1.5" @ 2.4" @ 4" @ 12" 24" 36" D 62 MAX D:S = 10:1 S 1.4" @ 2" @ 12" 24" D 62 MAX + D:S = 12:1 3.4" @ 36" gtt08-11.eps 14
62 MAX/62 MAX + Users Manual 12 38 mm @ 60 mm @ 100 mm @ 300 mm 600 mm 900 mm 13 33 mm @ 50 mm @ 85 mm @ 300 mm 600 mm 900 mm S 1.5" @ 2.4" @ 4" @ 12" 24" 36" D 62 MAX D:S = 10:1 S 1.4" @ 2" @ 12" 24" D 62 MAX + D:S = 12:1 3.4" @ 36" gtt08-11.eps 14