Dell Networking Installation Guide
Page 11
... Command Line Reference Guide for the S6000 System and the FTOS Configuration Guide for the S6000 system. Table 2-1 through the CLI show commands and with simple network management protocol (SNMP) traps. • Temperature monitoring • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for power management • Removable fan that you can view S6000 status information in several ways, including LEDs and boot menu options. Also, you can manage...
... Command Line Reference Guide for the S6000 System and the FTOS Configuration Guide for the S6000 system. Table 2-1 through the CLI show commands and with simple network management protocol (SNMP) traps. • Temperature monitoring • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for power management • Removable fan that you can view S6000 status information in several ways, including LEDs and boot menu options. Also, you can manage...
Dell Networking Installation Guide
Page 45
... interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment. Ground the shields at both ends. • Use only reverse airflow configurations in a NEBS-compliant installation. • Fit the power supplies and fan modules with AC Power Ports, use a SPD at the AC input of the FCC Rules. Replace the fan filters on optical ports • 802.3u...
... interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment. Ground the shields at both ends. • Use only reverse airflow configurations in a NEBS-compliant installation. • Fit the power supplies and fan modules with AC Power Ports, use a SPD at the AC input of the FCC Rules. Replace the fan filters on optical ports • 802.3u...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 52
... other command modes (for example, the CONFIGURATION or ROUTER OSPF modes). Usage Optionally, use the banner exec command to replace the enable xfp-power-updates command. Replacement command for the polling is displayed when the user accesses the EXEC mode. www.dell.com | support.dell.com Version 8.3.11.1 Version 8.3.10.0 Introduced on the Z9000 to create a text string that display. 52 | Control and Monitoring Syntax end Command Modes CONFIGURATION, SPANNING TREE, MULTIPLE SPANNING TREE, LINE, INTERFACE, TRACE-LIST, VRRP, ACCESS-LIST, PREFIX-LIST...
... other command modes (for example, the CONFIGURATION or ROUTER OSPF modes). Usage Optionally, use the banner exec command to replace the enable xfp-power-updates command. Replacement command for the polling is displayed when the user accesses the EXEC mode. www.dell.com | support.dell.com Version 8.3.11.1 Version 8.3.10.0 Introduced on the Z9000 to create a text string that display. 52 | Control and Monitoring Syntax end Command Modes CONFIGURATION, SPANNING TREE, MULTIPLE SPANNING TREE, LINE, INTERFACE, TRACE-LIST, VRRP, ACCESS-LIST, PREFIX-LIST...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 84
... 1 -- Unit Bay Status Type 1 0 up AC 1 1 absent 2 0 up 84 | Control and Monitoring To display the reload mode, use the command show system brief Stack MAC : 0:1:e8:d6:4:70 -- Modified output: Boot Flash field will display code level for S-Series switches Usage Figure shows the output from the show system brief command. Module Info -- Fan Status -- Modified output: brief parameter no longer displays the current reload mode. Modified output: Added...
... 1 -- Unit Bay Status Type 1 0 up AC 1 1 absent 2 0 up 84 | Control and Monitoring To display the reload mode, use the command show system brief Stack MAC : 0:1:e8:d6:4:70 -- Modified output: Boot Flash field will display code level for S-Series switches Usage Figure shows the output from the show system brief command. Module Info -- Fan Status -- Modified output: brief parameter no longer displays the current reload mode. Modified output: Added...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 327
... a comma; Introduced on . Defaults 0x10 Command Modes PROTOCOL LLDP Command History Version 9.0.2.0 Version 8.3.16.0 Introduced on the S6000. pfc mode on S6000 Enable the PFC configuration on the port so that will still function as global DCB operation is on MXL 10/40GbE Switch IO Module Usage Information By applying a DCB input policy with peer PFC devices. PFC and link-level flow control cannot be enabled at the global...
... a comma; Introduced on . Defaults 0x10 Command Modes PROTOCOL LLDP Command History Version 9.0.2.0 Version 8.3.16.0 Introduced on the S6000. pfc mode on S6000 Enable the PFC configuration on the port so that will still function as global DCB operation is on MXL 10/40GbE Switch IO Module Usage Information By applying a DCB input policy with peer PFC devices. PFC and link-level flow control cannot be enabled at the global...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 350
... Information The unit numbers given are internal port numbers. Enter the keywords cpu party-bus statistics, to select a stack ID. Enter the keyword stack-unit to display the Management plane input/output counter statistics of the S-Series have only port-pipe 0. Defaults No default behavior Command Modes EXEC Privilege Command History Version 9.0.2.0 Version 8.3.11.1 Introduced on S6000 Introduced on internal/hardware port number" and "option user-port 0-127 (in the FTOS Configuration Guide for the...
... Information The unit numbers given are internal port numbers. Enter the keywords cpu party-bus statistics, to select a stack ID. Enter the keyword stack-unit to display the Management plane input/output counter statistics of the S-Series have only port-pipe 0. Defaults No default behavior Command Modes EXEC Privilege Command History Version 9.0.2.0 Version 8.3.11.1 Introduced on S6000 Introduced on internal/hardware port number" and "option user-port 0-127 (in the FTOS Configuration Guide for the...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 424
...s z S6000 Configure the Management port on then S6000. Syntax interface ManagementEthernet slot/port Parameters slot/port Enter the keyword ManagementEthernet followed by default (no shutdown). Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.2.1.0 Introduced on the system. interface ManagementEthernet Command Example FTOS(conf)#interface managementethernet 0/0 FTOS(conf-if-ma-0/0)# You cannot delete a Management port. Configure a Null interface. The Management port is enabled by slot number (0-5) and port number zero (0). Clear FIB entries...
...s z S6000 Configure the Management port on then S6000. Syntax interface ManagementEthernet slot/port Parameters slot/port Enter the keyword ManagementEthernet followed by default (no shutdown). Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.2.1.0 Introduced on the system. interface ManagementEthernet Command Example FTOS(conf)#interface managementethernet 0/0 FTOS(conf-if-ma-0/0)# You cannot delete a Management port. Configure a Null interface. The Management port is enabled by slot number (0-5) and port number zero (0). Clear FIB entries...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 430
.... monitor interface [interface] To disable monitoring and return to verify that the far end of a WAN link remains up . See Chapter 6, Access Control Lists (ACL). Related Commands interface interface loopback interface null interface port-channel show vlan shutdown tagged untagged Configure a physical interface. Disable/Enable the VLAN. Introduced on the S4810 Usage Information When you configure no keepalive. The screen is up even if the remote end is not transmitting data. www.dell...
.... monitor interface [interface] To disable monitoring and return to verify that the far end of a WAN link remains up . See Chapter 6, Access Control Lists (ACL). Related Commands interface interface loopback interface null interface port-channel show vlan shutdown tagged untagged Configure a physical interface. Disable/Enable the VLAN. Introduced on the S4810 Usage Information When you configure no keepalive. The screen is up even if the remote end is not transmitting data. www.dell...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 828
... zero (0) or 7 as clear text. • 7 means that the password is not encrypted and stored as the encryption type for the key entered. Set the number of times the RADIUS server will attempt to the global default values. Defaults Not configured. Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 9.0.0.0 Version 8.3.11.1 Version 7.7.1.0 Version 7.6.1.0 Introduced on the S6000. Set a authentication key for all RADIUS communications between the switch and the RADIUS host server. Set the time interval...
... zero (0) or 7 as clear text. • 7 means that the password is not encrypted and stored as the encryption type for the key entered. Set the number of times the RADIUS server will attempt to the global default values. Defaults Not configured. Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 9.0.0.0 Version 8.3.11.1 Version 7.7.1.0 Version 7.6.1.0 Introduced on the S6000. Set a authentication key for all RADIUS communications between the switch and the RADIUS host server. Set the time interval...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 876
... snmp ifmib ifalias long Defaults Interface description truncated beyond 63 characters Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 7.6.1.0 Introduced on the S6000. snmp ifmib ifalias long Command Example FTOS#config!------command run on host connected to switch snmpwalk -c public 10.10.10.130 .1.3.6.1.2.1.31 | grep -i alias | more IF-MIB::ifAlias.134530304 = STRING: This is a port connected to 63 characters. show snmp user Command Example FTOS#show snmp user User name: v1v2creadu Engine ID: 0000178B02000001E80214A8 storage-type...
... snmp ifmib ifalias long Defaults Interface description truncated beyond 63 characters Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 7.6.1.0 Introduced on the S6000. snmp ifmib ifalias long Command Example FTOS#config!------command run on host connected to switch snmpwalk -c public 10.10.10.130 .1.3.6.1.2.1.31 | grep -i alias | more IF-MIB::ifAlias.134530304 = STRING: This is a port connected to 63 characters. show snmp user Command Example FTOS#show snmp user User name: v1v2creadu Engine ID: 0000178B02000001E80214A8 storage-type...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 880
... changes, the security digests of the SNMP Engine ID has important side effects. www.dell.com | support.dell.com Related Commands snmp-server community Enable SNMP and set to the private enterprise number. • The remaining 8 octets are configured on the router Display the SNMP running -config snmp Display SNMP engine and all remote engines that identifies the copy of the SNMP on the remote device. Range: 0 to 65535 Default: 162 Defaults As above Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version...
... changes, the security digests of the SNMP Engine ID has important side effects. www.dell.com | support.dell.com Related Commands snmp-server community Enable SNMP and set to the private enterprise number. • The remaining 8 octets are configured on the router Display the SNMP running -config snmp Display SNMP engine and all remote engines that identifies the copy of the SNMP on the remote device. Range: 0 to 65535 Default: 162 Defaults As above Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 884
... Related Commands snmp-server enable traps snmp-server community Enable SNMP traps. Usage Information In order to configure the router to receive most notifications, at least one snmp-server enable command and the snmp-server host command for the host. If you enter the command with access rights. 4. Only the last snmp-server host command will replace the first. Configure a remote user. 3. Configure a host to enable multiple hosts, you must be configured, with the snmp-server enable command. Enable traps. 5. Defaults Not configured. 884 | Simple Network Management...
... Related Commands snmp-server enable traps snmp-server community Enable SNMP traps. Usage Information In order to configure the router to receive most notifications, at least one snmp-server enable command and the snmp-server host command for the host. If you enter the command with access rights. 4. Only the last snmp-server host command will replace the first. Configure a remote user. 3. Configure a host to enable multiple hosts, you must be configured, with the snmp-server enable command. Enable traps. 5. Defaults Not configured. 884 | Simple Network Management...
FTOS 9.0(2.0) Command Line Reference Guide for the System
Page 944
... Set a port (physical ports only) to FFFF Default: 9100 Defaults 0x9100 Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.3.7.0 Introduced on Z9000. Syntax vlan-stack trunk To remove a trunk port designation from all Stackable VLAN-enabled VLANs. See Chapter 40, Service Provider Bridging. 944 | VLAN Stacking Introduced on S6000. Command Modes INTERFACE Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.3.7.0 Introduced on S4810. www.dell.com | support.dell.com Syntax vlan-stack protocol-type number Parameters number...
... Set a port (physical ports only) to FFFF Default: 9100 Defaults 0x9100 Command Modes CONFIGURATION Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.3.7.0 Introduced on Z9000. Syntax vlan-stack trunk To remove a trunk port designation from all Stackable VLAN-enabled VLANs. See Chapter 40, Service Provider Bridging. 944 | VLAN Stacking Introduced on S6000. Command Modes INTERFACE Command History Version 9.0.2.0 Version 8.3.11.1 Version 8.3.7.0 Introduced on S4810. www.dell.com | support.dell.com Syntax vlan-stack protocol-type number Parameters number...
FTOS 9.0(2.0) Configuration Guide for the System
Page 218
... reload-type normal-reload command. 196 | Bare Metal Provisioning 2.0 (BMP 2.0) Supported on S55 and S60. BMP 2.0 Supported on management and user ports. Supports TFTP, FTP, HTTP, USB, and flash. This mode is set with the reload-type jump-start ). This is the default startup mode. Supported on S4810 and S6000. You can reconfigure a switch to DHCP and file servers from both user and management ports, avoiding the need for dedicated management servers. Supports TFTP. www.dell.com | support.dell...
... reload-type normal-reload command. 196 | Bare Metal Provisioning 2.0 (BMP 2.0) Supported on S55 and S60. BMP 2.0 Supported on management and user ports. Supports TFTP, FTP, HTTP, USB, and flash. This mode is set with the reload-type jump-start ). This is the default startup mode. Supported on S4810 and S6000. You can reconfigure a switch to DHCP and file servers from both user and management ports, avoiding the need for dedicated management servers. Supports TFTP. www.dell.com | support.dell...
FTOS 9.0(2.0) Configuration Guide for the System
Page 316
... congestion management (BCN), logical link down (LLDF), and network interface virtualization (NIV). and FCF-facing interfaces as auto-downstream ports. 3. Configure server-facing interfaces as auto-upstream ports. 2. For more information, Refer to use IEEE 802.1Qaz (Draft 2.5). interface type slot/port [no ] DCBx version {auto | cee | cin | ieee-v2.5} Command Mode CONFIGURATION INTERFACE PROTOCOL LLDP 294 | Data Center Bridging (DCB) Default: Auto. [no ] protocol lldp Configure the DCBx version used on the switch. www.dell.com | support.dell.com...
... congestion management (BCN), logical link down (LLDF), and network interface virtualization (NIV). and FCF-facing interfaces as auto-downstream ports. 3. Configure server-facing interfaces as auto-upstream ports. 2. For more information, Refer to use IEEE 802.1Qaz (Draft 2.5). interface type slot/port [no ] DCBx version {auto | cee | cin | ieee-v2.5} Command Mode CONFIGURATION INTERFACE PROTOCOL LLDP 294 | Data Center Bridging (DCB) Default: Auto. [no ] protocol lldp Configure the DCBx version used on the switch. www.dell.com | support.dell.com...
FTOS 9.0(2.0) Configuration Guide for the System
Page 414
... full duplex only. The only configuration applicable to carry the PAUSE commands. Threshold Settings s Threshold Settings are supported only on ), 2 thresholds can process, the frames are supported on platforms: z z Ethernet Pause Frames allow full duplex flow control, stations implementing the pause operation instruct the MAC to enable reception of time. www.dell.com | support.dell.com Table 20-3 lists the range for a period of...
... full duplex only. The only configuration applicable to carry the PAUSE commands. Threshold Settings s Threshold Settings are supported only on ), 2 thresholds can process, the frames are supported on platforms: z z Ethernet Pause Frames allow full duplex flow control, stations implementing the pause operation instruct the MAC to enable reception of time. www.dell.com | support.dell.com Table 20-3 lists the range for a period of...
FTOS 9.0(2.0) Configuration Guide for the System
Page 742
... method lists, to define the types of all commands related to login authentication, refer to help secure networks against unauthorized access. User-defined method lists take precedence over the default method list. www.dell.com | support.dell.com No specific show command exists for different login methods and different users. Configuration Task List for AAA Authentication The following task in Privileged EXEC mode: Command Syntax show accounting Command Mode EXEC Privileged...
... method lists, to define the types of all commands related to login authentication, refer to help secure networks against unauthorized access. User-defined method lists take precedence over the default method list. www.dell.com | support.dell.com No specific show command exists for different login methods and different users. Configuration Task List for AAA Authentication The following task in Privileged EXEC mode: Command Syntax show accounting Command Mode EXEC Privileged...
FTOS 9.0(2.0) Configuration Guide for the System
Page 801
Dell Networking Enterprise-specific SNMP Traps Command Option envmon supply envmon temperature envmon fan xstp ecfm Trap HOT_FAILOVER: RPM Failover Completed SFM_DISCOVERY: Found SFM 1 SFM_REMOVE: Removed SFM 1 MAJOR_SFM: Major alarm: Switch fabric down FAN_OK: Minor alarm cleared: all fans in Domain customer1 at Level 7 VLAN 1000 %ECFM-5-ECFM_ERROR_ALARM: Error CCM Defect detected by MEP 1 in fan tray %d are good %SPANMGR-5-STP_NEW_ROOT: New Spanning Tree Root, Bridge...
Dell Networking Enterprise-specific SNMP Traps Command Option envmon supply envmon temperature envmon fan xstp ecfm Trap HOT_FAILOVER: RPM Failover Completed SFM_DISCOVERY: Found SFM 1 SFM_REMOVE: Removed SFM 1 MAJOR_SFM: Major alarm: Switch fabric down FAN_OK: Minor alarm cleared: all fans in Domain customer1 at Level 7 VLAN 1000 %ECFM-5-ECFM_ERROR_ALARM: Error CCM Defect detected by MEP 1 in fan tray %d are good %SPANMGR-5-STP_NEW_ROOT: New Spanning Tree Root, Bridge...
FTOS 9.0(2.0) Configuration Guide for the System
Page 871
... L3 routing on VLT Peers to the primary VLT switch over the VLT interconnect. Virtual Link Trunking (VLT) | 849 An access device never detects the change . Configure a backup link for the VLT domain. In case of a primary VLT switch failure, the secondary switch starts sending BPDUs with its own bridge ID and inherits all the port states from the last synchronization with its own...
... L3 routing on VLT Peers to the primary VLT switch over the VLT interconnect. Virtual Link Trunking (VLT) | 849 An access device never detects the change . Configure a backup link for the VLT domain. In case of a primary VLT switch failure, the secondary switch starts sending BPDUs with its own bridge ID and inherits all the port states from the last synchronization with its own...
FTOS 9.0(2.0) Configuration Guide for the System
Page 890
... your Dell Networking representative. Description Bandwidth monitoring Domain ID mismatch FTOS Version mismatch Remote VLT port channel status Spanning tree mismatch at global level Spanning tree mismatch at port level System MAC mismatch Behavior at Peer Up Behavior During Run Time Action to view VLT port channel status information. Depending on both VLT peers. N/A N/A Use the show vlt detail and show vlt brief commands...
... your Dell Networking representative. Description Bandwidth monitoring Domain ID mismatch FTOS Version mismatch Remote VLT port channel status Spanning tree mismatch at global level Spanning tree mismatch at port level System MAC mismatch Behavior at Peer Up Behavior During Run Time Action to view VLT port channel status information. Depending on both VLT peers. N/A N/A Use the show vlt detail and show vlt brief commands...