Contents Chapter 1 System Overview 1-1 System Features 1-1 System Memory 1-5 Advanced Expansion Subsystem 1-6 Integrated Server Management 1-6 Video Controller 1-6 Integrated SCSI Controller 1-6 SCSI Hard-Disk Drives 1-7 SCSI Configuration Guidelines 1-7 SCSI ID Numbers 1-7 Device Termination 1-8 System Unit 1-10 System Power Supply 1-10 Pin Assignments for the DC Power Connectors 1-10 DC Power Distribution 1-12 System Board Layout 1-14 System Board Jumpers 1-15 Interrupt Assignments 1-17 DMA Channel Assignments 1-18 Technical Specifications 1-19 v
Contents Chapter 1 System Overview 1-1 System Features 1-1 System Memory 1-5 Advanced Expansion Subsystem 1-6 Integrated Server Management 1-6 Video Controller 1-6 Integrated SCSI Controller 1-6 SCSI Hard-Disk Drives 1-7 SCSI Configuration Guidelines 1-7 SCSI ID Numbers 1-7 Device Termination 1-8 System Unit 1-10 System Power Supply 1-10 Pin Assignments for the DC Power Connectors 1-10 DC Power Distribution 1-12 System Board Layout 1-14 System Board Jumpers 1-15 Interrupt Assignments 1-17 DMA Channel Assignments 1-18 Technical Specifications 1-19 v
Service Manual
Page 6
... Figure 4-24. System Board Removal 4-24 Figure A-1. Advanced Menu A-6 Figure A-4. DC Voltage Ranges 1-10 Jumper Descriptions 1-16 Interrupt Assignments 1-17 DREQ Line Assignments 1-18 Technical Specifications 1-19 POST Beep Codes 3-1 System Error Messages 3-3 Key Functions A-2 Main Menu Categories A-4 Boot Options Submenu Categories A-5 Advanced Menu Categories A-7 Security Menu Categories A-9 Exit Menu Categories...
... Figure 4-24. System Board Removal 4-24 Figure A-1. Advanced Menu A-6 Figure A-4. DC Voltage Ranges 1-10 Jumper Descriptions 1-16 Interrupt Assignments 1-17 DREQ Line Assignments 1-18 Technical Specifications 1-19 POST Beep Codes 3-1 System Error Messages 3-3 Key Functions A-2 Main Menu Categories A-4 Boot Options Submenu Categories A-5 Advanced Menu Categories A-7 Security Menu Categories A-9 Exit Menu Categories...
Service Manual
Page 10
...drive bays • Recessed power and reset buttons to prevent accidental system interruptions All of system features, see the Dell PowerEdge 2200 Systems Rack Kit Installation Guide (P/N 87743). When following the text in this manual, assume that monitors operation of ...Computer Orientation 1-2 Dell PowerEdge 2200 Systems Service Manual For information about installing the PowerEdge 2200 systems in this chapter. tem cooling fan, as well as shown in this chapter. For a complete list of these features are briefly described in a rack, see "Technical Specifications" found later...
...drive bays • Recessed power and reset buttons to prevent accidental system interruptions All of system features, see the Dell PowerEdge 2200 Systems Rack Kit Installation Guide (P/N 87743). When following the text in this manual, assume that monitors operation of ...Computer Orientation 1-2 Dell PowerEdge 2200 Systems Service Manual For information about installing the PowerEdge 2200 systems in this chapter. tem cooling fan, as well as shown in this chapter. For a complete list of these features are briefly described in a rack, see "Technical Specifications" found later...
Service Manual
Page 27
... L2 cache Math coprocessor . . . . . or 16-bit ISA or 32-bit EISA (no shared expansion-card slots) ISA, EISA expansioncard connectors three full-length, 8- Technical Specifications Table 1-5. internal to the microprocessor System Information System chip set Intel 440FX controller chip set Data bus width 64 bits Address bus width. . . . . 32 bits...-pin sockets DIMM capacities . . . . . 32 and 128 MB (DIMMs are 60 ns or faster, buffered EDO) Standard RAM 32 MB (minimum) System Overview 1-19 Technical Specifications Microprocessor Microprocessor type . . .
... L2 cache Math coprocessor . . . . . or 16-bit ISA or 32-bit EISA (no shared expansion-card slots) ISA, EISA expansioncard connectors three full-length, 8- Technical Specifications Table 1-5. internal to the microprocessor System Information System chip set Intel 440FX controller chip set Data bus width 64 bits Address bus width. . . . . 32 bits...-pin sockets DIMM capacities . . . . . 32 and 128 MB (DIMMs are 60 ns or faster, buffered EDO) Standard RAM 32 MB (minimum) System Overview 1-19 Technical Specifications Microprocessor Microprocessor type . . .
Service Manual
Page 28
... a tape drive or CD-ROM drive Internally accessible bays three hard-disk drive bays for SCSI hard-disk drives up to a 3.5-inch diskette drive; Technical Specifications (continued) Memory (continued) Maximum RAM 512 MB BIOS address F000:0000h-F000:FFFFh External cache None Integrated SCSI Controller Type Adaptec AIC-7880 Ultra/Wide... . . . . . 34-pin connector Controls and Indicators Reset control push button Power control push button Power indicator green LED Diskette-drive access indicator green LED 1-20 Dell PowerEdge 2200 Systems Service Manual Table 1-5.
... a tape drive or CD-ROM drive Internally accessible bays three hard-disk drive bays for SCSI hard-disk drives up to a 3.5-inch diskette drive; Technical Specifications (continued) Memory (continued) Maximum RAM 512 MB BIOS address F000:0000h-F000:FFFFh External cache None Integrated SCSI Controller Type Adaptec AIC-7880 Ultra/Wide... . . . . . 34-pin connector Controls and Indicators Reset control push button Power control push button Power indicator green LED Diskette-drive access indicator green LED 1-20 Dell PowerEdge 2200 Systems Service Manual Table 1-5.
Service Manual
Page 29
Table 1-5. Technical Specifications (continued) Controls and Indicators (continued) Hard-disk drive access indicator green LED CD-ROM drive access indicator green LED Video Video type ATI mach64 (264VT) ...
Table 1-5. Technical Specifications (continued) Controls and Indicators (continued) Hard-disk drive access indicator green LED CD-ROM drive access indicator green LED Video Video type ATI mach64 (264VT) ...
Service Manual
Page 30
square wave form: 27 G for 2 ms; Table 1-5. Technical Specifications (continued) Environmental (continued) Maximum shock: Operating half-sine wave form: 50 G for 2 ms Storage half-sine wave form: 110 G for 15 ms Altitude: Operating 16 to 3048 m (-50 to 10,000 ft) Storage 16 to 10,600 m (-50 to 35,000 ft) z 1-22 Dell PowerEdge 2200 Systems Service Manual
square wave form: 27 G for 2 ms; Table 1-5. Technical Specifications (continued) Environmental (continued) Maximum shock: Operating half-sine wave form: 50 G for 2 ms Storage half-sine wave form: 110 G for 15 ms Altitude: Operating 16 to 3048 m (-50 to 10,000 ft) Storage 16 to 10,600 m (-50 to 35,000 ft) z 1-22 Dell PowerEdge 2200 Systems Service Manual
Service Manual
Page 36
... indicate where further testing is needed to run the selection. Restarting the computer causes the Dell Server Assistant logo screen to be inserted in the Diagnostics and Troubleshooting Guide. 2-6 Dell PowerEdge 2200 Systems Service Manual NOTE: Before running the diagnostics program, make a blank, formatted diskette... so that the system must be rebooted to isolate a failure • Run Specific Tests - Use the keyboard to choose Run System Utilities, and then select Run System Diagnostics to the Dell Server Assistant menu: • Run All Tests - A message appears indicating that...
... indicate where further testing is needed to run the selection. Restarting the computer causes the Dell Server Assistant logo screen to be inserted in the Diagnostics and Troubleshooting Guide. 2-6 Dell PowerEdge 2200 Systems Service Manual NOTE: Before running the diagnostics program, make a blank, formatted diskette... so that the system must be rebooted to isolate a failure • Run Specific Tests - Use the keyboard to choose Run System Utilities, and then select Run System Diagnostics to the Dell Server Assistant menu: • Run All Tests - A message appears indicating that...
Service Manual
Page 67
... enter the System Setup program. Contains configuration selec- NOTE: To ensure an orderly system shutdown, consult the documentation that accompanied the operating system. Displays item-specific help for the basic system configuration • Advanced menu - Provides selections for some selections have four boxed-in NVRAM on self-tests. Screen Conventions All...
... enter the System Setup program. Contains configuration selec- NOTE: To ensure an orderly system shutdown, consult the documentation that accompanied the operating system. Displays item-specific help for the basic system configuration • Advanced menu - Provides selections for some selections have four boxed-in NVRAM on self-tests. Screen Conventions All...
Service Manual
Page 69
... help box title box Dell System PowerEdge 2200 Setup Main Advanced Security Exit Time: [5:01:96] Date: [June 04, 1997] Diskette Drive A: [1.44 MB, 3.5 inch] Diskette Drive B: [Not Installed] Fast Video BIOS: [On and Cached] Memory Cache: [Enable] Boot Sequence: [A: then C:] Numlock: [On] Speaker: [On] BIOS Version AXX Item Specific Help Resets the time...
... help box title box Dell System PowerEdge 2200 Setup Main Advanced Security Exit Time: [5:01:96] Date: [June 04, 1997] Diskette Drive A: [1.44 MB, 3.5 inch] Diskette Drive B: [Not Installed] Fast Video BIOS: [On and Cached] Memory Cache: [Enable] Boot Sequence: [A: then C:] Numlock: [On] Speaker: [On] BIOS Version AXX Item Specific Help Resets the time...
Service Manual
Page 71
... power on the front bezel System Setup Program A-5 Boot Options Submenu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Boot Options Boot Sequence: [A: then C:] SETUP Prompt: [Enabled] POST Errors: [Enabled] Diskette Drive Check: [Enabled] Reset Button: [Enabled] BIOS Version AXX Item Specific Help Determines the order of diskette drive during boot Reset Button...
... power on the front bezel System Setup Program A-5 Boot Options Submenu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Boot Options Boot Sequence: [A: then C:] SETUP Prompt: [Enabled] POST Errors: [Enabled] Diskette Drive Check: [Enabled] Reset Button: [Enabled] BIOS Version AXX Item Specific Help Determines the order of diskette drive during boot Reset Button...
Service Manual
Page 72
... A-6 Dell PowerEdge 2200 Systems Service Manual F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu F9 Setup Defaults F10 Previous Values Figure A-3. Advanced Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Serial Port 1: Serial Port 2: Parallel Port: Parallel Mode: Diskette Controller: Onboard SCSI: PCI Scan Sequence Use MP specification PS...
... A-6 Dell PowerEdge 2200 Systems Service Manual F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu F9 Setup Defaults F10 Previous Values Figure A-3. Advanced Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Serial Port 1: Serial Port 2: Parallel Port: Parallel Mode: Diskette Controller: Onboard SCSI: PCI Scan Sequence Use MP specification PS...
Service Manual
Page 73
...'s built-in parallel port acts as a boot drive. Auto selects the next available combination. and Auto. Auto selects the next available combination. Use MP Specifications Configures the Multiprocessor Specification level. Parallel Port Selects a unique address and interrupt request for Serial Port 2. however, some operating systems use 1.1. Serial Port 2 Selects a unique address and...
...'s built-in parallel port acts as a boot drive. Auto selects the next available combination. and Auto. Auto selects the next available combination. Use MP Specifications Configures the Multiprocessor Specification level. Parallel Port Selects a unique address and interrupt request for Serial Port 2. however, some operating systems use 1.1. Serial Port 2 Selects a unique address and...
Service Manual
Page 74
... menu. Security Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Supervisor Password is User Password is Set Supervisor Password Set User Password Password on Boot: Diskette Access: System Backup Reminder: Virus Check Reminder: Disabled Disabled [Press Enter] [Press Enter] [Disabled] [User] [Disabled] [Disabled] BIOS Version AXX Item Specific Help Pressing displays a dialog...
... menu. Security Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Supervisor Password is User Password is Set Supervisor Password Set User Password Password on Boot: Diskette Access: System Backup Reminder: Virus Check Reminder: Disabled Disabled [Press Enter] [Press Enter] [Disabled] [User] [Disabled] [Disabled] BIOS Version AXX Item Specific Help Pressing displays a dialog...
Service Manual
Page 76
F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu Figure A-5. Exit Menu F9 Setup Defaults F10 Previous Values A-10 Dell PowerEdge 2200 Systems Service Manual Exit Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Save Changes & Exit Exit Without Saving Changes Get Default Values Load Previous Values Save Changes BIOS Version AXX Item Specific Help Saves all changes made in the Setup program to CMOS, exits the Setup program, and then reboots the computer.
F1 Help ESC Exit Select Item Select Menu -/+ Change Values Enter Select Sub-Menu Figure A-5. Exit Menu F9 Setup Defaults F10 Previous Values A-10 Dell PowerEdge 2200 Systems Service Manual Exit Menu Dell System PowerEdge 2200 Setup Main Advanced Security Exit Save Changes & Exit Exit Without Saving Changes Get Default Values Load Previous Values Save Changes BIOS Version AXX Item Specific Help Saves all changes made in the Setup program to CMOS, exits the Setup program, and then reboots the computer.
Service Manual
Page 79
... power, 1-12 CD-ROM drive access indicator location, 1-3 location, 1-4, 4-8 removal, 4-9 computer back/left side internal view, 1-5 cover removal, 4-3 front/right side internal view, 1-4 orientation, 1-2 technical specifications, 1-19 configuration guidelines SCSI drives, 1-7 configuration jumpers descriptions, 1-16 locations, 1-14, 1-15, 4-15 connectors locations, 1-14, 4-15 control panel assembly location, 1-4 removal, 4-7 D DC power connectors...
... power, 1-12 CD-ROM drive access indicator location, 1-3 location, 1-4, 4-8 removal, 4-9 computer back/left side internal view, 1-5 cover removal, 4-3 front/right side internal view, 1-4 orientation, 1-2 technical specifications, 1-19 configuration guidelines SCSI drives, 1-7 configuration jumpers descriptions, 1-16 locations, 1-14, 1-15, 4-15 connectors locations, 1-14, 4-15 control panel assembly location, 1-4 removal, 4-7 D DC power connectors...
Service Manual
Page 81
..., 1-3 resource conflicts, eliminating, 2-5 S SCSI configuration guidelines, 1-7 SCSI connector, 4-15 SCSI controller, integrated, 1-6 SCSI devices ID numbers, 1-7 SCSI hard-disk drives. See drives SERIAL connector, 4-15 specifications, technical, 1-19 subsystems, advanced expansion, 1-6 SVR_MGT connector, 4-15 system battery removal, 4-23 system board assembly, removal, 4-17 component locations, 1-14, 4-15 illustrated, 1-14 jumpers, 1-15...
..., 1-3 resource conflicts, eliminating, 2-5 S SCSI configuration guidelines, 1-7 SCSI connector, 4-15 SCSI controller, integrated, 1-6 SCSI devices ID numbers, 1-7 SCSI hard-disk drives. See drives SERIAL connector, 4-15 specifications, technical, 1-19 subsystems, advanced expansion, 1-6 SVR_MGT connector, 4-15 system battery removal, 4-23 system board assembly, removal, 4-17 component locations, 1-14, 4-15 illustrated, 1-14 jumpers, 1-15...
Service Manual
Page 82
... combinations, A-3 screen conventions, A-1 Security menu, A-8 starting, A-1 T technical specifications, 1-19 TEMP_1 connector, 4-15 TEMP_2 connector, 4-15 termination jumpers SCSI drives, 1-8 terminator card removal, 4-21 troubleshooting boot routine, observing, 2-3 external visual inspection, 2-2 initial procedures, 2-1 initial user contact, 2-1 internal visual inspection, 2-4 U user contact, initial, 2-1 V video controller, integrated, 1-6 visual inspection external, 2-2 internal, 2-4 4 Dell PowerEdge 2200 Systems Service Manual
... combinations, A-3 screen conventions, A-1 Security menu, A-8 starting, A-1 T technical specifications, 1-19 TEMP_1 connector, 4-15 TEMP_2 connector, 4-15 termination jumpers SCSI drives, 1-8 terminator card removal, 4-21 troubleshooting boot routine, observing, 2-3 external visual inspection, 2-2 initial procedures, 2-1 initial user contact, 2-1 internal visual inspection, 2-4 U user contact, initial, 2-1 V video controller, integrated, 1-6 visual inspection external, 2-2 internal, 2-4 4 Dell PowerEdge 2200 Systems Service Manual