User's Guide (.htm)
Page 21
.... The device also provides one RS-232 console port. The PowerConnect 3424P also provides Power over Ethernet (PoE). PowerConnect 3424P The PowerConnect 3424P provides 24 10/100Mbps ports plus two SFP ports, and two Copper ports which can function either as a stand-alone device. PowerConnect 3424 and PowerConnect 3424P Introduction 21 Figure 1-1. This User Guide contains the...
.... The device also provides one RS-232 console port. The PowerConnect 3424P also provides Power over Ethernet (PoE). PowerConnect 3424P The PowerConnect 3424P provides 24 10/100Mbps ports plus two SFP ports, and two Copper ports which can function either as a stand-alone device. PowerConnect 3424 and PowerConnect 3424P Introduction 21 Figure 1-1. This User Guide contains the...
User's Guide (.htm)
Page 22
www.dell.com | support.dell.com PowerConnect 3448 The PowerConnect 3448 provides 48 10/100Mbps ports plus two SFP ports, and two Copper ports which the stack is selected as the Stack Master and another ... and PowerConnect 3448P Stacking Overview PowerConnect 3424/P and PowerConnect 3448/P stacking provides multiple switch management through which can be used to six units per stack, or can operate as the Backup Master. Switch software is part of a Stacking Unit 22 Introduction In addition, PowerConnect 3448P provides PoE. The device also provides one RS-232 console port...
www.dell.com | support.dell.com PowerConnect 3448 The PowerConnect 3448 provides 48 10/100Mbps ports plus two SFP ports, and two Copper ports which the stack is selected as the Stack Master and another ... and PowerConnect 3448P Stacking Overview PowerConnect 3424/P and PowerConnect 3448/P stacking provides multiple switch management through which can be used to six units per stack, or can operate as the Backup Master. Switch software is part of a Stacking Unit 22 Introduction In addition, PowerConnect 3448P provides PoE. The device also provides one RS-232 console port...
User's Guide (.htm)
Page 28
...Transmissions are forwarded before packets at the end of all updated device features, see "Running Cable Diagnostics". 28 Introduction www.dell.com | support.dell.com Features Overview This section describes the device features. Virtual Cable Testing (VCT) VCT detects and reports copper link cabling... occurrences such as open cables and cable shorts. PoE removes the need for ports or LAGs, see "Defining Port Configuration" or "...
...Transmissions are forwarded before packets at the end of all updated device features, see "Running Cable Diagnostics". 28 Introduction www.dell.com | support.dell.com Features Overview This section describes the device features. Virtual Cable Testing (VCT) VCT detects and reports copper link cabling... occurrences such as open cables and cable shorts. PoE removes the need for ports or LAGs, see "Defining Port Configuration" or "...
User's Guide (.htm)
Page 40
...: • Width - 440 mm (17.32 inch) • Depth - 387 mm (15.236 inch) • Height - 43.2 mm (1.7 inch) Non-PoE Device: • Width - 440 mm (17.32 inch) • Depth - 257 mm (10.118 inch) • Height - 43.2 mm (1.7 inch) LED Definitions ... FDX The RJ-45 100 Base-T port on the PowerConnect 3424 /P and PowerConnect 3448/P has two LEDs marked as LNK/ACT. 40 Hardware Description The speed LED is located on the right side. www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10...
...: • Width - 440 mm (17.32 inch) • Depth - 387 mm (15.236 inch) • Height - 43.2 mm (1.7 inch) Non-PoE Device: • Width - 440 mm (17.32 inch) • Depth - 257 mm (10.118 inch) • Height - 43.2 mm (1.7 inch) LED Definitions ... FDX The RJ-45 100 Base-T port on the PowerConnect 3424 /P and PowerConnect 3448/P has two LEDs marked as LNK/ACT. 40 Hardware Description The speed LED is located on the right side. www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10...
User's Guide (.htm)
Page 45
... internal power supply unit (AC unit) and a connector to connect PowerConnect 3424/P and PowerConnect 3448/P devices to a PowerConnect EPS-470 unit, or to connect PowerConnect 3424 and PowerConnect 3448 devices to 63 Hz. The PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply (12 Volt). AC Power...that the device is not the Stack Master. Hardware Description 45 Table 2-6. Operation with a total of 370W for 24 ports PoE device. LED indicator is not designated as Stacking Unit N. The following figure illustrates the LEDs on the front panel and indicates ...
... internal power supply unit (AC unit) and a connector to connect PowerConnect 3424/P and PowerConnect 3448/P devices to a PowerConnect EPS-470 unit, or to connect PowerConnect 3424 and PowerConnect 3448 devices to 63 Hz. The PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply (12 Volt). AC Power...that the device is not the Stack Master. Hardware Description 45 Table 2-6. Operation with a total of 370W for 24 ports PoE device. LED indicator is not designated as Stacking Unit N. The following figure illustrates the LEDs on the front panel and indicates ...
User's Guide (.htm)
Page 47
...both Unit 1 and Unit 2 are present, the unit that indicates if one or more fans is 4. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have five built-in stand-alone mode. Stack members receive a separate Unit ID (3-6). For example, if there are not...elected functions as the Backup Master. If the Master device is reset, the entire stack is booted in fans. The non-PoE PowerConnect 3424 and PowerConnect 3448 devices have a reset button, located on the Unit ID of booting the device. Operation can be selected within 15 ...
...both Unit 1 and Unit 2 are present, the unit that indicates if one or more fans is 4. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have five built-in stand-alone mode. Stack members receive a separate Unit ID (3-6). For example, if there are not...elected functions as the Backup Master. If the Master device is reset, the entire stack is booted in fans. The non-PoE PowerConnect 3424 and PowerConnect 3448 devices have a reset button, located on the Unit ID of booting the device. Operation can be selected within 15 ...
User's Guide (.htm)
Page 49
...radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures. • Ambient Requirements - Installing the PowerConnect 3424/P and PowerConnect 3448/P Site Preparation The PowerConnect 3424 /P and PowerConnect 3448/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed ...on a tabletop or mounted on the front panel are illuminated. • PoE Models - There is correctly installed by ...
...radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures. • Ambient Requirements - Installing the PowerConnect 3424/P and PowerConnect 3448/P Site Preparation The PowerConnect 3424 /P and PowerConnect 3448/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed ...on a tabletop or mounted on the front panel are illuminated. • PoE Models - There is correctly installed by ...
User's Guide (.htm)
Page 99
... fields: Unit No. - Not Present - The power supply is displayed. The temperature at which the device asset information is currently not present. Figure 6-4. The non-PoE devices have two fans, while the PoE devices have five fans. Not Present - Fan Status - Power Supply Status -
... fields: Unit No. - Not Present - The power supply is displayed. The temperature at which the device asset information is currently not present. Figure 6-4. The non-PoE devices have two fans, while the PoE devices have five fans. Not Present - Fan Status - Power Supply Status -
User's Guide (.htm)
Page 101
...are connected via Ethernet ports. Configuring System Information 101 Powered Devices are connected to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. click System →General →Power over Ethernet removes...cabling, without updating or modifying the network infrastructure. To open the Power Over Ethernet page. Powered Devices are devices which receive power from the PowerConnect power supplies, for example IP phones. Unit ---1 1 2 2 Sensor -----1 2 1 2 Temperature (Celsius 41 41 42 42 Status -----OK...
...are connected via Ethernet ports. Configuring System Information 101 Powered Devices are connected to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. click System →General →Power over Ethernet removes...cabling, without updating or modifying the network infrastructure. To open the Power Over Ethernet page. Powered Devices are devices which receive power from the PowerConnect power supplies, for example IP phones. Unit ---1 1 2 2 Sensor -----1 2 1 2 Temperature (Celsius 41 41 42 42 Status -----OK...
User's Guide (.htm)
Page 102
.... Off - Indicates that the power supply unit is 1-99 percent. System Usage Threshold (1-99 Percent) - Consumed Power - Indicates the inline power source status. www.dell.com | support.dell.com Figure 6-5. Nominal Power - Indicates the amount of power the device can supply. Traps - The field value is not functioning. Indicates that the power... fields: Power Status - For example, a power overload or a short circuit. Indicates the percentage of power consumed before an alarm is generated. Enables or Disables receiving PoE device traps.
.... Off - Indicates that the power supply unit is 1-99 percent. System Usage Threshold (1-99 Percent) - Consumed Power - Indicates the inline power source status. www.dell.com | support.dell.com Figure 6-5. Nominal Power - Indicates the amount of power the device can supply. Traps - The field value is not functioning. Indicates that the power... fields: Power Status - For example, a power overload or a short circuit. Indicates the percentage of power consumed before an alarm is generated. Enables or Disables receiving PoE device traps.
User's Guide (.htm)
Page 103
... level. Power Consumption - The possible field values are : On - Indicates that the PowerConnect device has detected a fault on PoE. Port Settings Select a Port - Indicates the device PoE mode. The Device Discovery Protocol enables the device to discover Powered Devices attached to the ...The field values are classified by the powered device, and the PowerConnect devices use the classification information. Indicates that the PowerConnect device is assigned a power consumption level of .44 to 12.95 Watts. 0.44 - 3.8 - PoE Admin Status - This is low. Indicates the device is ...
... level. Power Consumption - The possible field values are : On - Indicates that the PowerConnect device has detected a fault on PoE. Port Settings Select a Port - Indicates the device PoE mode. The Device Discovery Protocol enables the device to discover Powered Devices attached to the ...The field values are classified by the powered device, and the PowerConnect devices use the classification information. Indicates that the PowerConnect device is assigned a power consumption level of .44 to 12.95 Watts. 0.44 - 3.8 - PoE Admin Status - This is low. Indicates the device is ...
User's Guide (.htm)
Page 104
..., and the device is assigned a power consumption level of the inline power on the Power Over Ethernet page. Managing PoE Using the CLI Commands The following table summarizes the equivalent CLI commands for viewing fields displayed on an interface. Absent Counter.... Signatures are generated during powered device detection, classification, or maintenance. www.dell.com | support.dell.com 3.84 - 6.49 - Overload Counter - Denied Counter - Indicate the times an invalid signature was received. Defining PoE Settings 1 Open the Power Over Ethernet page. 2 Define the fields. ...
..., and the device is assigned a power consumption level of the inline power on the Power Over Ethernet page. Managing PoE Using the CLI Commands The following table summarizes the equivalent CLI commands for viewing fields displayed on an interface. Absent Counter.... Signatures are generated during powered device detection, classification, or maintenance. www.dell.com | support.dell.com 3.84 - 6.49 - Overload Counter - Denied Counter - Indicate the times an invalid signature was received. Defining PoE Settings 1 Open the Power Over Ethernet page. 2 Define the fields. ...
User's Guide (.htm)
Page 105
Table 6-16. System Health CLI Commands (continued) CLI Command Description power inline Configures the threshold for triggering alarms usage-threshold power inline traps enable Enables PoE device traps show power inline ethernet 1/e1 Port Powered Device State Priority Status Classification [W] 1/1e IP Phone Model A Auto High On 0.44 - 12.95 ... A Auto High On 0.44 - 12.95 2/e1 Wireless AP Model Auto Low On 0.44 - 3.84 3/e1 Auto Low Off N/A Console# show power inline Displays PoE configuration information [ethernet interface ] The following is an example of the...
Table 6-16. System Health CLI Commands (continued) CLI Command Description power inline Configures the threshold for triggering alarms usage-threshold power inline traps enable Enables PoE device traps show power inline ethernet 1/e1 Port Powered Device State Priority Status Classification [W] 1/1e IP Phone Model A Auto High On 0.44 - 12.95 ... A Auto High On 0.44 - 12.95 2/e1 Wireless AP Model Auto Low On 0.44 - 3.84 3/e1 Auto Low Off N/A Console# show power inline Displays PoE configuration information [ethernet interface ] The following is an example of the...
User's Guide (.htm)
Page 401
..., 29, 249, 394 MDI/MDIX, 76 MDIX, 29, 249, 394 MDU, 394 Message, 111 Message digest 5, 111, 394 MIB, 189, 394 Multicast, 331 PING, 395 PoE, 21, 28, 101 Port, 39 Port LEDs, 40 Port mirroring, 260 Ports, 81, 246, 368 Power over Ethernet, 21, 28, 101 Power supplies, 45, 98...
..., 29, 249, 394 MDI/MDIX, 76 MDIX, 29, 249, 394 MDU, 394 Message, 111 Message digest 5, 111, 394 MIB, 189, 394 Multicast, 331 PING, 395 PoE, 21, 28, 101 Port, 39 Port LEDs, 40 Port mirroring, 260 Ports, 81, 246, 368 Power over Ethernet, 21, 28, 101 Power supplies, 45, 98...