... Other ports will occur under two conditions: first, if the total power consumption exceeds the system power limit; DES-3828P includes the following PoE features: The auto-discovery feature recognizes the connection of a PD (Powered Device) and automatically...Link 802.3af capable devices. PDs receive power according to the following classification: Class 0 1 2 3 Max power used by PD 0.44 to 12.95W 0.44 to 3.84W 3.84 to 6.49W 6.49 to 12.95W PSE provides power according to it. xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual 7 POE COMMANDS DES-3828P...
... Other ports will occur under two conditions: first, if the total power consumption exceeds the system power limit; DES-3828P includes the following PoE features: The auto-discovery feature recognizes the connection of a PD (Powered Device) and automatically...Link 802.3af capable devices. PDs receive power according to the following classification: Class 0 1 2 3 Max power used by PD 0.44 to 12.95W 0.44 to 3.84W 3.84 to 6.49W 6.49 to 12.95W PSE provides power according to it. xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual 7 POE COMMANDS DES-3828P...
Product Manual
Page 151
... from the total available rules. Now take into account the rule limit. a single access rule was created. xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual Command Parameters | offset_64-79 } port [permit {priority {replace_priority} | replace_dscp } | deny |...source_ipv6 | destionation_ipv6 } port [permit {priority {replace_priority}} | deny] | delete ] Due to the 800 rule Switch limit. The rules used above - That is described as well. DES-3828/DES-3828DC/DES-3828P DES-3852 Port Numbers 1 - 8 9 - 16 17 - 24 25 - 32 33 - 40 41 - ...
... from the total available rules. Now take into account the rule limit. a single access rule was created. xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual Command Parameters | offset_64-79 } port [permit {priority {replace_priority} | replace_dscp } | deny |...source_ipv6 | destionation_ipv6 } port [permit {priority {replace_priority}} | deny] | delete ] Due to the 800 rule Switch limit. The rules used above - That is described as well. DES-3828/DES-3828DC/DES-3828P DES-3852 Port Numbers 1 - 8 9 - 16 17 - 24 25 - 32 33 - 40 41 - ...
Product Manual
Page 444
... port) Automatic update. Default = 300. 440 xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual Internal power supply Power Consumption DC fans: Operating Temperature Storage Temperature Humidity Dimensions Weight EMI: Safety: Physical and Environmental DES-3828/DES-3852 AC Input: 100 - 120; 200 - 240 VAC, 50/60 Hz DES-3828P AC Input: 100 - 120; 200 - 240...
... port) Automatic update. Default = 300. 440 xStack DES-3800 Series Layer 3 Stackable Fast Ethernet Managed Switch CLI Manual Internal power supply Power Consumption DC fans: Operating Temperature Storage Temperature Humidity Dimensions Weight EMI: Safety: Physical and Environmental DES-3828/DES-3852 AC Input: 100 - 120; 200 - 240 VAC, 50/60 Hz DES-3828P AC Input: 100 - 120; 200 - 240...