Installation Guide
Page 1
Catalyst 4900 Series Switch Installation Guide August 2008 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: 78-18039-02
Catalyst 4900 Series Switch Installation Guide August 2008 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number: 78-18039-02
Installation Guide
Page 2
...your own expense. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. These limits are designed to part 15 of the television or radio. • Move the equipment farther away from the television or radio..., in a particular installation. You can radiate radio-frequency energy and, if not installed and used in accordance with Cisco's installation instructions, it off. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS ...
...your own expense. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. These limits are designed to part 15 of the television or radio. • Move the equipment farther away from the television or radio..., in a particular installation. You can radiate radio-frequency energy and, if not installed and used in accordance with Cisco's installation instructions, it off. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS ...
Installation Guide
Page 41
Table 2-1 lists the power cords that are used with the appropriate AC power cord for your location. Table 2-1 AC-Input Power Cord Options Locale Part Number 300 W AC Power Supply Length Plug Rating Appliance Coupler Plug Type 120352 North America CAB-US515-C15-US= (was CAB-7KAC=) 8.2 ft (2.5 m) ...AS/NZS 3112-1993 120356 Europe (except CAB-CEE77-C15-EU= 8.2 ft (2.5 m) 250 VAC, 16 A CEE 7/7 Italy) (was CAB-7ACE=) 120357 78-18039-02 Catalyst 4900 Series Switch Installation Guide 2-5 Chapter 2 Site Planning Site Power Requirements You will also need to provide power to the...
Table 2-1 lists the power cords that are used with the appropriate AC power cord for your location. Table 2-1 AC-Input Power Cord Options Locale Part Number 300 W AC Power Supply Length Plug Rating Appliance Coupler Plug Type 120352 North America CAB-US515-C15-US= (was CAB-7KAC=) 8.2 ft (2.5 m) ...AS/NZS 3112-1993 120356 Europe (except CAB-CEE77-C15-EU= 8.2 ft (2.5 m) 250 VAC, 16 A CEE 7/7 Italy) (was CAB-7ACE=) 120357 78-18039-02 Catalyst 4900 Series Switch Installation Guide 2-5 Chapter 2 Site Planning Site Power Requirements You will also need to provide power to the...
Installation Guide
Page 42
... or other interior ground system with number 6 AWG wire. Grounding Requirements Chapter 2 Site Planning Table 2-1 Locale Italy AC-Input Power Cord Options (continued) Part Number CAB-C2316-C15-IT= (was CAB-7ACI=) Length Plug Rating Plug Type 8.2 ft (2.5 m) 250 VAC, 16 A 1/3/16 CEI 23-16 ...203795 Grounding Requirements Grounding is recommended on the right side of the chassis, and either one may be used. (See Figure 2-1.) Catalyst 4900 Series Switch Installation Guide 2-6 78-18039-02 Attach the provided two hole ground lug to the chassis using only approved copper connectors.
... or other interior ground system with number 6 AWG wire. Grounding Requirements Chapter 2 Site Planning Table 2-1 Locale Italy AC-Input Power Cord Options (continued) Part Number CAB-C2316-C15-IT= (was CAB-7ACI=) Length Plug Rating Plug Type 8.2 ft (2.5 m) 250 VAC, 16 A 1/3/16 CEI 23-16 ...203795 Grounding Requirements Grounding is recommended on the right side of the chassis, and either one may be used. (See Figure 2-1.) Catalyst 4900 Series Switch Installation Guide 2-6 78-18039-02 Attach the provided two hole ground lug to the chassis using only approved copper connectors.
Installation Guide
Page 44
... 60364, Part 1 through Part 7 Working Safely with Electricity Follow these basic guidelines when working with the following local and national electrical codes: - United States-National Fire Protection Association (NFPA 70); See the "Lifting the Chassis Safely" section on page 3-5 before lifting the switch. •... room in which you are uncertain that could get caught in the chassis. United States National Electrical Code - Catalyst 4900 Series Switch Installation Guide 2-8 78-18039-02 Safety Overview Chapter 2 Site Planning Warning This equipment must be grounded. Statement...
... 60364, Part 1 through Part 7 Working Safely with Electricity Follow these basic guidelines when working with the following local and national electrical codes: - United States-National Fire Protection Association (NFPA 70); See the "Lifting the Chassis Safely" section on page 3-5 before lifting the switch. •... room in which you are uncertain that could get caught in the chassis. United States National Electrical Code - Catalyst 4900 Series Switch Installation Guide 2-8 78-18039-02 Safety Overview Chapter 2 Site Planning Warning This equipment must be grounded. Statement...
Installation Guide
Page 52
.... The depth must fit between the inner edges of a Catalyst 4948-10GE switch. Measure the space between the mounting posts.) d. Use a tape measure to install the chassis in a rack. Table 3-1 Rack-Mount Kit Checklist Quantity 2 8 Part Description L brackets M4 x 8 mm Phillips flat-head screws Received Catalyst 4900 Series Switch Installation Guide 3-6 78-18039-02 Rack-Mounting the...
.... The depth must fit between the inner edges of a Catalyst 4948-10GE switch. Measure the space between the mounting posts.) d. Use a tape measure to install the chassis in a rack. Table 3-1 Rack-Mount Kit Checklist Quantity 2 8 Part Description L brackets M4 x 8 mm Phillips flat-head screws Received Catalyst 4900 Series Switch Installation Guide 3-6 78-18039-02 Rack-Mounting the...
Installation Guide
Page 53
Step 2 Note that the L brackets connect the chassis to the Switch 130086 PS1 PS2 FAN STATUS 1 16 17 32 33 Catalyst WS-C4948 10GE X2-1 X2-2 CON 48 MGT Step 3 Install the chassis in the rack-mount kit. (See Figure 3-2.) Figure 3-2 Attaching the L Brackets ... the chassis, determine whether to install the chassis from the front or the rear of the switch to the rack. Chapter 3 Installing the Switch Rack-Mounting the Switch Table 3-1 Quantity 4 4 Rack-Mount Kit Checklist Part Description Received 12-24 x 3/4-inch Phillips binder-head screws 10-32 x 3/4-inch Phillips binder...
Step 2 Note that the L brackets connect the chassis to the Switch 130086 PS1 PS2 FAN STATUS 1 16 17 32 33 Catalyst WS-C4948 10GE X2-1 X2-2 CON 48 MGT Step 3 Install the chassis in the rack-mount kit. (See Figure 3-2.) Figure 3-2 Attaching the L Brackets ... the chassis, determine whether to install the chassis from the front or the rear of the switch to the rack. Chapter 3 Installing the Switch Rack-Mounting the Switch Table 3-1 Quantity 4 4 Rack-Mount Kit Checklist Part Description Received 12-24 x 3/4-inch Phillips binder-head screws 10-32 x 3/4-inch Phillips binder...
Installation Guide
Page 57
... these steps and warnings when connecting DC power to the Catalyst 4900 series switch: Warning Before performing any of the following procedures, ensure that power is in service. If the LEDs or show power command to be present on...be provided as part of security. Install only in restricted access areas. Be sure uninsulated conductors are not in place. For more information on DC power terminals. Statement 1017 Warning This product requires short-circuit (overcurrent) protection, to display the power supply and system status. Chapter 3 Installing the Switch Connecting DC ...
... these steps and warnings when connecting DC power to the Catalyst 4900 series switch: Warning Before performing any of the following procedures, ensure that power is in service. If the LEDs or show power command to be present on...be provided as part of security. Install only in restricted access areas. Be sure uninsulated conductors are not in place. For more information on DC power terminals. Statement 1017 Warning This product requires short-circuit (overcurrent) protection, to display the power supply and system status. Chapter 3 Installing the Switch Connecting DC ...
Installation Guide
Page 126
... Compliance Appendix C Compliance Information and Translated Safety Warnings Table C-1 Class A Regulatory Standards Compliance (continued) Specification EMC Standard EN 60950-1 IEC 60950-1 AS/NZS 60950-1 FCC Part 15 (CFR 47) Class A ICES-003 Class A EN50082-1 CISPR22 Class A AS/NZS CISPR22 Class A VCCI Class A EN55022 Class A EN55024 EN61000-3-2 EN6100-3-3 EN61000-6-1 ... Levels Verizon NEBS Compliance Standard SR-3580 NEBS level 3 (GRC-63-CORE issue 3, GR-1089-CORE , issue 4 Telecommunications Carrier Group (TCG) Checklist C-40 Catalyst 4900 Series Switch Installation Guide 78-18039-02
... Compliance Appendix C Compliance Information and Translated Safety Warnings Table C-1 Class A Regulatory Standards Compliance (continued) Specification EMC Standard EN 60950-1 IEC 60950-1 AS/NZS 60950-1 FCC Part 15 (CFR 47) Class A ICES-003 Class A EN50082-1 CISPR22 Class A AS/NZS CISPR22 Class A VCCI Class A EN55022 Class A EN55024 EN61000-3-2 EN6100-3-3 EN61000-6-1 ... Levels Verizon NEBS Compliance Standard SR-3580 NEBS level 3 (GRC-63-CORE issue 3, GR-1089-CORE , issue 4 Telecommunications Carrier Group (TCG) Checklist C-40 Catalyst 4900 Series Switch Installation Guide 78-18039-02
Installation Guide
Page 133
...een woonomgeving kan dit product radiostoring veroorzaken. In a domestic environment this equipment in a residential area is een product van klasse A. These limits are designed to Part 15 of this product may cause radio interference in which case users will be required to radio communications. Appendix C Compliance Information and Translated Safety Warnings... produit peut entraîner des perturbations radioélectriques, auquel cas l'utilisateur devra éventuellement prendre des mesures adéquates. 78-18039-02 Catalyst 4900 Series Switch Installation Guide C-47
...een woonomgeving kan dit product radiostoring veroorzaken. In a domestic environment this equipment in a residential area is een product van klasse A. These limits are designed to Part 15 of this product may cause radio interference in which case users will be required to radio communications. Appendix C Compliance Information and Translated Safety Warnings... produit peut entraîner des perturbations radioélectriques, auquel cas l'utilisateur devra éventuellement prendre des mesures adéquates. 78-18039-02 Catalyst 4900 Series Switch Installation Guide C-47