Hardware Installation Guide
Page 4
Contents 2 C H A P T E R Rear-Panel Description 1-21 Power Connectors 1-22 Internal Power Supply Connector 1-22 DC Power Connector 1-23 Cisco RPS Connector 1-23 Console Port 1-24 Management Options 1-24 Installation 2-1 Preparing for Installation 2-1 Warnings 2-1 Installation Guidelines 2-4 Verifying Package Contents 2-5 Verifying Switch Operation 2-6 Installing the Switch 2-7 Installing the Switch in a Rack 2-7 Attaching the Brackets to the Switch 2-8 Mounting the Switch in a Rack 2-16 Attaching the Optional...
Contents 2 C H A P T E R Rear-Panel Description 1-21 Power Connectors 1-22 Internal Power Supply Connector 1-22 DC Power Connector 1-23 Cisco RPS Connector 1-23 Console Port 1-24 Management Options 1-24 Installation 2-1 Preparing for Installation 2-1 Warnings 2-1 Installation Guidelines 2-4 Verifying Package Contents 2-5 Verifying Switch Operation 2-6 Installing the Switch 2-7 Installing the Switch in a Rack 2-7 Attaching the Brackets to the Switch 2-8 Mounting the Switch in a Rack 2-16 Attaching the Optional...
Hardware Installation Guide
Page 8
... Repair, or Refund Policy for Hardware Cisco or its exclusive warranty remedy. To Receive a Return Materials Authorization (RMA) Number Contact the company from Company telephone number Product model number Product serial number Maintenance contract number Catalyst 2950 Switch Hardware Installation Guide viii OL-6156-01... as long as its service center will use the product, provided that the fan and power supply warranty is limited to five (5) years from Cisco, contact your Cisco Sales and Service Representative. If you purchased the product. Complete the information below, and keep...
... Repair, or Refund Policy for Hardware Cisco or its exclusive warranty remedy. To Receive a Return Materials Authorization (RMA) Number Contact the company from Company telephone number Product model number Product serial number Maintenance contract number Catalyst 2950 Switch Hardware Installation Guide viii OL-6156-01... as long as its service center will use the product, provided that the fan and power supply warranty is limited to five (5) years from Cisco, contact your Cisco Sales and Service Representative. If you purchased the product. Complete the information below, and keep...
Hardware Installation Guide
Page 23
... supported by certain Catalyst 2950 LRE switches. Connection for an optional Cisco RPS 300 redundant power system (RPS) that uses AC input and supplies DC output to the switch - For more information on the console port on these switches, see the "Power Connectors" section on page 1-24. Table 1-1 LRE Switch and CPE Compatibility Matrix LRE Devices Catalyst 2950ST-8 LRE Cisco 575 LRE Yes...
... supported by certain Catalyst 2950 LRE switches. Connection for an optional Cisco RPS 300 redundant power system (RPS) that uses AC input and supplies DC output to the switch - For more information on the console port on these switches, see the "Power Connectors" section on page 1-24. Table 1-1 LRE Switch and CPE Compatibility Matrix LRE Devices Catalyst 2950ST-8 LRE Cisco 575 LRE Yes...
Hardware Installation Guide
Page 36
... 1-3 lists the LED colors and meanings. System is receiving power but is not powered up power. For information about the Cisco RPS 300, see Table 1-5) determine the type of information displayed. 1-16 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 Solid green RPS is not...RPS is off or is providing power to the switch (redundancy has been allocated to this device). If it is receiving power and functioning properly. Release the button to enable the highlighted mode. Contact Cisco Systems. Flashing amber The internal power supply in a fault condition. Each...
... 1-3 lists the LED colors and meanings. System is receiving power but is not powered up power. For information about the Cisco RPS 300, see Table 1-5) determine the type of information displayed. 1-16 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 Solid green RPS is not...RPS is off or is providing power to the switch (redundancy has been allocated to this device). If it is receiving power and functioning properly. Release the button to enable the highlighted mode. Contact Cisco Systems. Flashing amber The internal power supply in a fault condition. Each...
Hardware Installation Guide
Page 42
... from your Cisco sales representative: • CAB-NP1200-AC-AR= • CAB-NP1200-AC-AU= • CAB-NP1200-AC-CH= • CAB-NP1200-AC-EU= 1-22 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 Internal Power Supply Connector The internal AC power supply is on the front panel of the Catalyst 2950ST-8 LRE and Catalyst 2950ST-24 LRE switches. Note The...
... from your Cisco sales representative: • CAB-NP1200-AC-AR= • CAB-NP1200-AC-AU= • CAB-NP1200-AC-CH= • CAB-NP1200-AC-EU= 1-22 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 Internal Power Supply Connector The internal AC power supply is on the front panel of the Catalyst 2950ST-8 LRE and Catalyst 2950ST-24 LRE switches. Note The...
Hardware Installation Guide
Page 43
.... It automatically senses when the internal power supply of a connected device fails and provides power to that has an input supply voltage from -36 to the switch. Warning Attach only the Cisco RPS 675 (model PWR675-AC-RPS-N1=) to DC Power." Cisco RPS Connector Specific Cisco RPS models support specific Catalyst 2950 switches: • Cisco RPS 300 (model PWR300-AC-RPS-N1...
.... It automatically senses when the internal power supply of a connected device fails and provides power to that has an input supply voltage from -36 to the switch. Warning Attach only the Cisco RPS 675 (model PWR675-AC-RPS-N1=) to DC Power." Cisco RPS Connector Specific Cisco RPS models support specific Catalyst 2950 switches: • Cisco RPS 300 (model PWR300-AC-RPS-N1...
Hardware Installation Guide
Page 47
Read these topics, and perform the procedures in this order: • Preparing for the Catalyst 2950 Switch. Statement 100B OL-6156-01 Catalyst 2950 Switch Hardware Installation Guide 2-1 Warning Attach only the Cisco Redundant Power Supply (RPS) (model PWR300-AC-RPS-N1) to Go Next, page 2-40 Preparing for Installation This section provides information about these topics...; Connecting to SFP Modules, page 2-38 • Where to the RPS receptacle. Installation CH A P T E R 2 This chapter describes how to install your switch, interpret the power-on self-test (POST), and connect the...
Read these topics, and perform the procedures in this order: • Preparing for the Catalyst 2950 Switch. Statement 100B OL-6156-01 Catalyst 2950 Switch Hardware Installation Guide 2-1 Warning Attach only the Cisco Redundant Power Supply (RPS) (model PWR300-AC-RPS-N1) to Go Next, page 2-40 Preparing for Installation This section provides information about these topics...; Connecting to SFP Modules, page 2-38 • Where to the RPS receptacle. Installation CH A P T E R 2 This chapter describes how to install your switch, interpret the power-on self-test (POST), and connect the...
Hardware Installation Guide
Page 62
.... Use the supplied black Phillips machine screw to attach the cable guide to the switch. Note You cannot use the four Phillips machine screws to securely attach the brackets to the rack, as shown in the rack, start the terminal-emulation software, and provide power to the left...8x 9x 10x 11x 10Base-T / 100Base-TX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x Catalyst 2950 SERIES 24x 45573 Cable guide screw 2-16 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 See the getting started guide for instructions. Attaching the Optional Cable Guide We ...
.... Use the supplied black Phillips machine screw to attach the cable guide to the switch. Note You cannot use the four Phillips machine screws to securely attach the brackets to the rack, as shown in the rack, start the terminal-emulation software, and provide power to the left...8x 9x 10x 11x 10Base-T / 100Base-TX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x Catalyst 2950 SERIES 24x 45573 Cable guide screw 2-16 Catalyst 2950 Switch Hardware Installation Guide OL-6156-01 See the getting started guide for instructions. Attaching the Optional Cable Guide We ...
Hardware Installation Guide
Page 63
...Switch to a Wall, page 2-18 Attaching the Brackets to the Switch Use the supplied Phillips flat-head screws to attach a bracket to the switch. See the getting started guide for the Catalyst 2950 Switch OL-6156-01 47303 Phillips truss-head screws Catalyst 2950 Switch Hardware Installation Guide 2-17 Installing the Switch...the switch bottom. Statement 265 You can mount the Catalyst 2950 switch to the switch, install an RPS connector cover on a table, shelf, or desk near an AC power source or DC-input power source. Start the terminal-emulation software and provide power to the switch. ...
...Switch to a Wall, page 2-18 Attaching the Brackets to the Switch Use the supplied Phillips flat-head screws to attach a bracket to the switch. See the getting started guide for the Catalyst 2950 Switch OL-6156-01 47303 Phillips truss-head screws Catalyst 2950 Switch Hardware Installation Guide 2-17 Installing the Switch...the switch bottom. Statement 265 You can mount the Catalyst 2950 switch to the switch, install an RPS connector cover on a table, shelf, or desk near an AC power source or DC-input power source. Start the terminal-emulation software and provide power to the switch. ...
Hardware Installation Guide
Page 65
... ground lug and hardware (Cisco part number NEBS-LUG-3550...for Catalyst 2950 Switches For switches that exerts up wall mounting configuration After the switch is mounted on the wall, power the switch as ...Catalyst 2950 Switch Hardware Installation Guide 2-19 Chapter 2 Installation Figure 2-20 Mounting a Catalyst 2950 Switch to a Wall Vertical wall stud Installing the Switch Vertical wall stud Catalyst 2950 SERIES LRE 2A 2B 13 14 15 16 17 18 19 20 21 22 23 24 9 10 11 12 1.01A/000.-51A275/02-R06A00-TI2HN4ZM0GVO~DE SPEESDTAT RPS SYST CONSOLE 1 2 3 4 5 6 7 8 86317 User-supplied...
... ground lug and hardware (Cisco part number NEBS-LUG-3550...for Catalyst 2950 Switches For switches that exerts up wall mounting configuration After the switch is mounted on the wall, power the switch as ...Catalyst 2950 Switch Hardware Installation Guide 2-19 Chapter 2 Installation Figure 2-20 Mounting a Catalyst 2950 Switch to a Wall Vertical wall stud Installing the Switch Vertical wall stud Catalyst 2950 SERIES LRE 2A 2B 13 14 15 16 17 18 19 20 21 22 23 24 9 10 11 12 1.01A/000.-51A275/02-R06A00-TI2HN4ZM0GVO~DE SPEESDTAT RPS SYST CONSOLE 1 2 3 4 5 6 7 8 86317 User-supplied...
Hardware Installation Guide
Page 114
...To ensure that has an input supply voltage from the DC circuit. If the supply voltage is OFF, locate the circuit breaker on the chassis. Note This installation must comply with 5-A-branch-circuit protection. Wiring the DC-Input Power Source Warning Only trained and qualified... damaged. Caution The switch must connect the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch only to -72 VDC. Catalyst 2950 Switch Hardware Installation Guide C-4 OL-6156-01 CONSOLE Appendix C Connecting to DC Power 65295 Torque to the OFF position, and tape the switch handle of the circuit...
...To ensure that has an input supply voltage from the DC circuit. If the supply voltage is OFF, locate the circuit breaker on the chassis. Note This installation must comply with 5-A-branch-circuit protection. Wiring the DC-Input Power Source Warning Only trained and qualified... damaged. Caution The switch must connect the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch only to -72 VDC. Catalyst 2950 Switch Hardware Installation Guide C-4 OL-6156-01 CONSOLE Appendix C Connecting to DC Power 65295 Torque to the OFF position, and tape the switch handle of the circuit...
Hardware Installation Guide
Page 121
... 5x 6x 7x 8x 9x 10x 11x 10BASE-T / 100BASE-TX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x Catalyst 2950 SERIES 24x 100BASE-FX 25 26 2 89367 3 1 Catalyst 2950 switch 3 AC power cord 2 RJ-45-to-DB-9 adapter cable Note You need to provide the Category 5 straight-through cables to connect the...-45-to perform the initial configuration. Follow these steps to connect the PC or terminal to the switch: Step 1 Step 2 Using the supplied RJ-45-to-DB-9 adapter cable, insert the RJ-45 connector into the console port on the rear of the adapter cable to a PC serial ...
... 5x 6x 7x 8x 9x 10x 11x 10BASE-T / 100BASE-TX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x Catalyst 2950 SERIES 24x 100BASE-FX 25 26 2 89367 3 1 Catalyst 2950 switch 3 AC power cord 2 RJ-45-to-DB-9 adapter cable Note You need to provide the Category 5 straight-through cables to connect the...-45-to perform the initial configuration. Follow these steps to connect the PC or terminal to the switch: Step 1 Step 2 Using the supplied RJ-45-to-DB-9 adapter cable, insert the RJ-45 connector into the console port on the rear of the adapter cable to a PC serial ...
Hardware Installation Guide
Page 123
... is powered on. For instructions about connecting the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch to DC power, see Appendix C, "Connecting to configure and manage the switch. When the switch powers on the switch front ...Catalyst 2950 Switch Hardware Installation Guide D-5 Note For an LRE switch, connect one end of the supplied AC power cord to complete the setup program, which runs automatically after the switch is also required if you plan to use the Network Assistant to DC Power." Figure D-2 shows how to connect the AC power cord to a Cisco redundant power...
... is powered on. For instructions about connecting the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch to DC power, see Appendix C, "Connecting to configure and manage the switch. When the switch powers on the switch front ...Catalyst 2950 Switch Hardware Installation Guide D-5 Note For an LRE switch, connect one end of the supplied AC power cord to complete the setup program, which runs automatically after the switch is also required if you plan to use the Network Assistant to DC Power." Figure D-2 shows how to connect the AC power cord to a Cisco redundant power...
Hardware Installation Guide
Page 132
... requirements A-1 to A-4 supply AC connector 2-22 DC connector 2-23 RPS connector 2-23 power connectors 2-22 to 2-23 procedures connecting to DC power C-1 to C-7 connection 3-27 to 3-40 installation 3-7 to 3-18 IP address 3-40 publications, related xv to xvi IN-6 Catalyst 2950 Switch Hardware Installation Guide R ...LED 2-16 S safety agency approvals A-5 to A-6 safety warnings 3-1 to 3-4 SFP module bale-clasp latch illustrated 3-24 SFP modules actuator button latch illustrated 3-24 actuator button latch, removing 3-26 bale-clasp latch, removing 3-26 connecting to 3-38 to 3-40 described 2-11 ...
... requirements A-1 to A-4 supply AC connector 2-22 DC connector 2-23 RPS connector 2-23 power connectors 2-22 to 2-23 procedures connecting to DC power C-1 to C-7 connection 3-27 to 3-40 installation 3-7 to 3-18 IP address 3-40 publications, related xv to xvi IN-6 Catalyst 2950 Switch Hardware Installation Guide R ...LED 2-16 S safety agency approvals A-5 to A-6 safety warnings 3-1 to 3-4 SFP module bale-clasp latch illustrated 3-24 SFP modules actuator button latch illustrated 3-24 actuator button latch, removing 3-26 bale-clasp latch, removing 3-26 connecting to 3-38 to 3-40 described 2-11 ...
Configuration Guide
Page 45
..., Catalyst 2950, Catalyst 3524-PWR XL, and Catalyst 3550 switches • Cisco RPS 600 (model PWR600-AC-RPS)-Catalyst 2950 switches, except the Catalyst 2900 LRE XL and Catalyst 3524-PWR XL switches Refer to another switch in standby mode. Blinking green RPS is connected and operational. Contact Cisco Systems. • The RPS fan could be in the stack. Contact Cisco Systems. Blinking amber Internal power supply...
..., Catalyst 2950, Catalyst 3524-PWR XL, and Catalyst 3550 switches • Cisco RPS 600 (model PWR600-AC-RPS)-Catalyst 2950 switches, except the Catalyst 2900 LRE XL and Catalyst 3524-PWR XL switches Refer to another switch in standby mode. Blinking green RPS is connected and operational. Contact Cisco Systems. • The RPS fan could be in the stack. Contact Cisco Systems. Blinking amber Internal power supply...