Get support for Cisco 6509E - Catalyst Switch

Cisco 6509E Support Question

Cisco 6509E Support Question

Find answers below for this question about Cisco 6509E - Catalyst Switch.
Need a Cisco 6509E manual? We have 1 online manual for this item!
Question posted by wneagle on July 26th, 2011

6509-e In Combined Mode. What Should Happen In The Event Of A Pwer Failure.

6509-E has two PWr 6000W pwr supplies in it. 6509 is in combined mode. Q1. if for example B Pwr S. goes bad or losse power does pwr S. take competely over at 6000W? Q2. If one leg of pwr from B pwr S. is lost, does remaining 2950 (1/2) of B, is it added to A pwr supply at 6000W to provide a total of 8950 or at 83% in combined mode final total 7400? Q3. In redundant mode (6509-E) configured a/b-a/b and conected to respective cks.  for true redundancy. Both pwr are 6000W. Q. is there a know problem that when one or two legs of the A and B pwr supplies  fail ,the power good supply only produces 1/2 of 6000W? Which in our case is well short of the 4400W we need to keep the switch up?  

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Cisco 6509E Manual Pages

Supervisor Guide - Page 2

...OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY. and other company. (1005R) Catalyst 6500 Series Supervisor Engine Guide Copyright © 1999-2011 Cisco Systems, Inc. All rights...California. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA...
Supervisor Guide - Page 4

...17 Attaching the Network Interface Cables 3-17 Attaching Optical Network Interface Cables 3-18 Mode-Conditioning Patch Cord 3-18 Connecting Transceivers to a Copper Network 3-22 Where to...Specifications B-1 Console Port B-1 Console Port Cables and Adapters B-1 CONSOLE PORT MODE Switch (Supervisor Engine 2 Only) B-2 Console Port Mode 2 Signaling and Pinouts B-5 Uplink Ports B-5 USB Ports B-7 Copper ...
Supervisor Guide - Page 6

...example, the key combination ^D in a screen display means hold down the Control key while you might do something that could result in equipment damage or loss of characters. Notes contain helpful suggestions or references to material not covered in the publication. Catalyst...Means reader take note. Arguments for which you supply values are optional. Nonprinting characters, such as ...
Supervisor Guide - Page 16

... (3) bottom), 4 RU, horizontal chassis supports redundant power supplies and redundant supervisor engines. The 3-slot (numbered from (1) top to run the configured features of the Catalyst 6503 switch. The Catalyst 6503-E switch chassis is an enhanced version of the switch. Catalyst 6503-E Chapter 1 Catalyst 6500 Series Switch Chassis Overview • Supervisor Engine 32, Supervisor...
Supervisor Guide - Page 18

Catalyst 6506 Chapter 1 Catalyst 6500 Series Switch Chassis Overview • Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2). Additionally, each supervisor engine must also install a 2500 W or higher capacity power supply in the same chassis. Supervisor engine support and restrictions for specific information...
Supervisor Guide - Page 20

... high-speed fan tray. You must also install a 2500 W or higher capacity power supply in the chassis to support the supervisor engines in the Catalyst 6509 chassis. • Supervisor Engine 2 must be installed in standby mode. Catalyst 6500 Series Supervisor Engine Guide 1-6 OL-7397-03 Each supervisor engine must be installed in the chassis. The chassis...
Supervisor Guide - Page 21

... a built-in standby mode. Supervisor engine support and restrictions for any restrictions on the type of the Catalyst 6509 switch. Note Refer to your software release notes for the Catalyst 6509-E includes: •... the switch on the minimum software release versions required to (9) bottom), 15 RU, horizontal chassis supports redundant power supplies and redundant supervisor engines.
Supervisor Guide - Page 22

... 720, and Supervisor Engine 720-10GE must be installed in standby mode. The Switch Fabric Modules and Supervisor Engine 720 or Supervisor Engine 720-10GE cannot...6509-NEB-UPGRD kit is a 9-slot (numbered from (1) right to run the configured features of module that supports redundant power supplies and redundant supervisor engines. Catalyst 6509-NEB Chapter 1 Catalyst 6500 Series Switch...
Supervisor Guide - Page 23

...be installed in standby mode. Note In systems with the smaller memory configuration is NEBS L3 compliant. Switch Fabric Modules (WS-...power supplies and redundant supervisor engines. Note Slots not occupied by Supervisor Engine 720 and Supervisor Engine 720-10GE. The Catalyst 6509-NEB-A switch chassis is sufficient to run the configured features of the Catalyst 6509-NEB switch...
Supervisor Guide - Page 24

...2T must be installed in standby mode. Note In systems with the smaller memory configuration is sufficient to run the switch on the minimum software release ...left), 21 RU, vertical chassis supports redundant power supplies, redundant supervisor engines, and redundant fan trays. Catalyst 6509-V-E Chapter 1 Catalyst 6500 Series Switch Chassis Overview • Supervisor Engine 32 and...
Supervisor Guide - Page 25

...switch on the Catalyst 6509-V-E switch chassis including data sheets and chassis installation is located at: http://www.cisco.com/en/US/products/hw/switches/ps708/tsd_products_support_series_home.html Catalyst 6513 The Catalyst 6513 switch...are fully functional on the type of module that supports redundant power supplies and redundant supervisor engines. Note Slots not occupied by Supervisor ...
Supervisor Guide - Page 30

... Backplane Hardware restrictions Description Supported on all Catalyst 6500 series chassis except the Catalyst 6509-V-E chassis. 12.2(17d)SXB All three versions of Supervisor Engine 2 are no additional hardware restrictions for Supervisor Engine 2. Slots 1 and 2 in any Catalyst 6500 series chassis 32-Gbps shared bus. 256 Gbps when a Switch Fabric Module (WS-C6500-SFM or...
Supervisor Guide - Page 34

... module terminates signals on the Catalyst switching bus. 2. If no redundant supervisor engine is installed and there is performing either a read or a write operation. 1. Supervisor Engine 2 Chapter 2 Supervisor Engines Table 2-4 Supervisor Engine 2 Front Panel LEDs (continued) LED PWR MGMT LINK (Uplink ports) Color and Meaning • Green-Sufficient power is available for all modules...
Supervisor Guide - Page 41

... active. • Orange-The supervisor engine is in the chassis. • Orange-Power-up mode; There is resetting; an overtemperature condition has occurred. Note If the supervisor engine fails to the system's overall power capacity before fully powering up . • Red-A major power failure has occurred. the supervisor engine does not come online. Off-The port...
Supervisor Guide - Page 48

... in standby mode. • Green-The supervisor engine is operational and active. • Orange-The supervisor engine is not connected. The supervisor engine monitors each module in standby mode. DISK 0 (PCMCIA) LED Off-The port is not active or the link is in the chassis. • Orange-Power-up . • Red-A major power failure has...
Supervisor Guide - Page 53

... supervisor engine is booting or running self-diagnostics. • Green-Power management is functioning normally and sufficient power is in the chassis. • Orange-Power-up . • Red-A major power failure has occurred. PWR MGMT The supervisor engine monitors each module's power requirements and status relative to power up mode; DISK 0 and DISK 1 LEDs These LEDs are reporting OK...
Supervisor Guide - Page 54

...ACTIVE PWR MGMT RESET SUPERVISOR 720 WITH INTEGRATED SWITCH ...FABRIC/PFC3 DISK 0 1-GE uplink CONSOLE ports port 10/100/1000 uplink port UPLINK 1 SFP 3 10/100/100 3 LINK LINK LINK CONSOLE 10-GE uplink ports 10GE UPLINK 4 5 LINK LINK STATUS LEDs CompactFlash LINK Type II slot LEDs Note: CompactFlash latch removed for clarity LINK LEDs USB ports 186480 2-26 Catalyst...
Supervisor Guide - Page 59

... Status LEDs LED STATUS SYSTEM ACTIVE PWR MGMT Color and Meaning The STATUS ...Power management is functioning normally and sufficient power is insufficient power for all modules to the system's overall power capacity before fully powering up each module in standby mode. The supervisor engine monitors each module's power requirements and status relative to power up mode; OL-7397-03 Catalyst...
Supervisor Guide - Page 61

...255278 1 STATUS LED 2 ID LED 3 SYSTEM LED 4 ACTIVE LED 5 PWR MGMT LED 6 RESET switch 7 PCMCIA slot 8 1000BASE-X UPLINK ports (requires SFP transceivers) 9 MANAGEMENT port... 10 CONSOLE port 11 10GBASE-X UPLINK ports (requires X2 transceivers 12 USB port 13 Port currently not supported OL-7397-03 Catalyst...
Supervisor Guide - Page 66

... to power up. • Red-A major power failure has...power management problem has been detected. Table 2-24 Supervisor Engine 2T Front Panel Status LEDs LED STATUS ID SYSTEM ACTIVE PWR...Power management is functioning normally and sufficient power is performing either a read operation or a write operation. 2-38 Catalyst 6500 Series Supervisor Engine Guide OL-7397-03 There is in standby mode...

Similar Questions

How To Configure Lelnet On Cisco 6504e Switch
after done the configuration of cisco 6405E swiitch, we are not able to telnet the switch, device is...
(Posted by sarwaransari 9 years ago)
Cisco Nme-x-23es-1g Initial Configuration
Following instructions in Cisco online docs. I set the ip address for gi 1/0 and attempt to connect ...
(Posted by droberts4 11 years ago)
Nme-x-23es-1g Initial Configuration
I am unable to contact the module: GW12#service-module gi 1/0 session % telnet connections not per...
(Posted by droberts4 11 years ago)
Cisco 6509-ve Sup720 Dcef
ACL (deny/log) vs. RPF strict-mode When applied on an Edge roters interface... is the ACL more proce...
(Posted by ccnpaz 12 years ago)
Configure A Cisco Srw2008p Switch For Cisco Ip Phone 7961.
How do I configure a Cisco SRW2008P switch for a Cisco IP Phone 7961. Currently if I plug this phone...
(Posted by victorluster 13 years ago)
Ask a New Question
Use the box below to post a new question about this Cisco product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Cisco Manuals

Find free Cisco 6509E - Catalyst Switch manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Cisco Reviews

View thousands of Cisco user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Cisco customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Cisco customer service rankings, employee comments and much more from our sister site.