M7VIB compatibility test report
Page 1
M7 VIB ENGINEERING VALIDATION TEST REPORT COVER SHEET CHANGE CONTROL Description of Change Initial Release For KT266A For VIA VT8233A Revision 0.90 1.0 1.1 1.1 2.0 2.3 2.4 2.5 3.2 Sections/Pages Affected Date 2001/3/21 2001/4/27 2001/7/17 2001/9/12 2001/10/2 2001/11/23 2002/1/22 2002/1/22 2002/2/19 Project: Date: Owner: Contact: M7 VIB VIA KT266/KT266A For AMD Athlon/Duron ATX Motherboard 2002/2/22 Biostar Group TEL: 886-2-2218-0150 FAX: 886-2-2218-1552 Home Page: http://www.biostar.com.tw 1
M7 VIB ENGINEERING VALIDATION TEST REPORT COVER SHEET CHANGE CONTROL Description of Change Initial Release For KT266A For VIA VT8233A Revision 0.90 1.0 1.1 1.1 2.0 2.3 2.4 2.5 3.2 Sections/Pages Affected Date 2001/3/21 2001/4/27 2001/7/17 2001/9/12 2001/10/2 2001/11/23 2002/1/22 2002/1/22 2002/2/19 Project: Date: Owner: Contact: M7 VIB VIA KT266/KT266A For AMD Athlon/Duron ATX Motherboard 2002/2/22 Biostar Group TEL: 886-2-2218-0150 FAX: 886-2-2218-1552 Home Page: http://www.biostar.com.tw 1
M7VIB compatibility test report
Page 2
CONTENTS PRODUCT INFORMATION 6 Motherboard General Information 6 Chipset Details ...6 BIOS Details ...6 CPU Support ...6 Memory Support ...6 On-board Features and Devices 6 Mechanical ...7 DESIGN REVIEW 9 Mainboard Voltage Measurement 9 Bus Clock ...9 REQUIRED BIOS ... Operating 25 Windows ME Operating 28 Windows XP (Home Edition ) Operating 33 Windows XP (Professional ) Operating 34 Linux (Red Hat) Operating 35 RELIABILITY TEST 37 Motherboard General Information 37 Burn-in Step ...37 OVER CLOCK TEST 38 Windows Me (FSB:100 MHz 38 Windows Me (FSB:133 MHz 39 PERFORMANCE TEST...
CONTENTS PRODUCT INFORMATION 6 Motherboard General Information 6 Chipset Details ...6 BIOS Details ...6 CPU Support ...6 Memory Support ...6 On-board Features and Devices 6 Mechanical ...7 DESIGN REVIEW 9 Mainboard Voltage Measurement 9 Bus Clock ...9 REQUIRED BIOS ... Operating 25 Windows ME Operating 28 Windows XP (Home Edition ) Operating 33 Windows XP (Professional ) Operating 34 Linux (Red Hat) Operating 35 RELIABILITY TEST 37 Motherboard General Information 37 Burn-in Step ...37 OVER CLOCK TEST 38 Windows Me (FSB:100 MHz 38 Windows Me (FSB:133 MHz 39 PERFORMANCE TEST...
M7VIB compatibility test report
Page 4
... FOUR CORNER TEST-Ver 0.9 107 FOUR CORNER TEST-Ver 1.0 108 FOUR CORNER TEST-Ver 1.1 109 4 Ver 0.9 100 Motherboard General Information 100 THERMAL IMAGE TEST - Ver 1.0 101 Motherboard General Information 101 THERMAL IMAGE TEST - Ver 2.4 105 Motherboard General Information 105 THERMAL IMAGE TEST - Vcore Ripple Test(Standby/Resume Mode 79 VCORE WAVEFORM MEASUREMENT (Athlon...
... FOUR CORNER TEST-Ver 0.9 107 FOUR CORNER TEST-Ver 1.0 108 FOUR CORNER TEST-Ver 1.1 109 4 Ver 0.9 100 Motherboard General Information 100 THERMAL IMAGE TEST - Ver 1.0 101 Motherboard General Information 101 THERMAL IMAGE TEST - Ver 2.4 105 Motherboard General Information 105 THERMAL IMAGE TEST - Vcore Ripple Test(Standby/Resume Mode 79 VCORE WAVEFORM MEASUREMENT (Athlon...
M7VIB compatibility test report
Page 6
PRODUCT INFORMATION Motherboard General Information Vendor Biostar Model Number M7 VIB Version Number V0.90/ V1.0/ V1.1/ V2.0/V2.3/V2.4/V2.5/V3.2 Platform AT ATX Micro ATX Flex ATX FCC Logo Ok ...
PRODUCT INFORMATION Motherboard General Information Vendor Biostar Model Number M7 VIB Version Number V0.90/ V1.0/ V1.1/ V2.0/V2.3/V2.4/V2.5/V3.2 Platform AT ATX Micro ATX Flex ATX FCC Logo Ok ...
M7VIB compatibility test report
Page 100
Ver 0.9 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 0.9 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 100 THERMAL IMAGE TEST -
Ver 0.9 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 0.9 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 100 THERMAL IMAGE TEST -
M7VIB compatibility test report
Page 101
Ver 1.0 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 1.0 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 101 THERMAL IMAGE TEST -
Ver 1.0 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 1.0 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 101 THERMAL IMAGE TEST -
M7VIB compatibility test report
Page 102
Ver 1.1 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 1.1 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 102 THERMAL IMAGE TEST -
Ver 1.1 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 1.1 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 102 THERMAL IMAGE TEST -
M7VIB compatibility test report
Page 103
Ver 2.0 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.0 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 103 THERMAL IMAGE TEST -
Ver 2.0 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.0 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 103 THERMAL IMAGE TEST -
M7VIB compatibility test report
Page 104
THERMAL IMAGE TEST - Ver 2.3 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.3 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 104
THERMAL IMAGE TEST - Ver 2.3 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.3 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 104
M7VIB compatibility test report
Page 105
THERMAL IMAGE TEST - Ver 2.4 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.4 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 105
THERMAL IMAGE TEST - Ver 2.4 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 2.4 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 105
M7VIB compatibility test report
Page 106
Ver 3.2 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 3.2 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 106 THERMAL IMAGE TEST -
Ver 3.2 Motherboard General Information Vendor Biostar Model Number M7VIB Revision 3.2 Temperature ( ℃ ) 35 ℃ Humidity rate ( % ) 0 ~ 60 % Thermo Tracer NEC TH5104 Test Program 3Dmark2000 Comments: The component temperature measured value was based on 35℃ check in the chamber and the system during in the 3Dmark2000 Looping testing. 106 THERMAL IMAGE TEST -