NP115 : RS232 codes- Projectors
Page 1
...HT10 : HT410/HT510 Series LT 180 LT180 LT30 : LT25/LT30/LT35 Series LT : LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41...Connection Method 3. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about NEC projector control commands. Projector Control 2. Command Descriptions 6. Projector Control NEC projectors make use of control commands that ...
...HT10 : HT410/HT510 Series LT 180 LT180 LT30 : LT25/LT30/LT35 Series LT : LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series LT80 : LT280/LT380 Series MT70 : MT860/MT1060/MT1065/MT1075 Series NP60 : NP40/NP50/NP60 Series NP62 : NP41...Connection Method 3. Control Commands for NEC Projector (Basic) Rev 02.03.11a Copyright (C) NEC Display Solutions, Ltd. 2002-2010 Updated on February 3, 2011 This file contains information about NEC projector control commands. Projector Control 2. Command Descriptions 6. Projector Control NEC projectors make use of control commands that ...
NP115 : RS232 codes- Projectors
Page 2
... using the serial port on the projector A USB cable is required. 2. USB connection using a wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. 1. LAN connection using the USB port on the projector A serial cable is required. 3.... LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. Connection Method The following 3...
... using the serial port on the projector A USB cable is required. 2. USB connection using a wired LAN card A wired LAN card and LAN cable are available for sending and receiving control commands. 1. LAN connection using the USB port on the projector A serial cable is required. 3.... LAN connection using the LAN port on the projector A LAN cable is required Status of connection methods are required. 3-2. Connection Method The following 3...
NP115 : RS232 codes- Projectors
Page 4
... The PC CONTROL connector is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". Supplement: (!1) Only the NP600/NP610/NP3200 series is compatible. (!2) Only the M300 series is a D-SUB 9-pin connector. Setting method...RS-232C standard. (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" ...
... The PC CONTROL connector is a mini DIN 8-pin connector. 1 To TxD of PC 2 3 4 To GND of PC 5 6 7 To RxD of the projector and set the "idle mode". Supplement: (!1) Only the NP600/NP610/NP3200 series is compatible. (!2) Only the M300 series is a D-SUB 9-pin connector. Setting method...RS-232C standard. (CAUTION) Before making connections, be sure to invalidate the standby mode of PC 8 * 2, 3, 5, 6, and 8 are used inside the projector. [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90) ] The PC CONTROL connector is compatible. [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" ...
NP115 : RS232 codes- Projectors
Page 5
... data, and checksum. Communication Frame On the LT/MT/SX/GT series projectors communication is an identification data assigned to send it. ( See each command. The response has two types; Command | | |... Bytes) | | |1|2|3| 4 |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is done in a frame composed of PC 9 4. Acknowledge (hereafter referred to as ACK) that recognizes a command and Negative Acknowledge...
... data, and checksum. Communication Frame On the LT/MT/SX/GT series projectors communication is an identification data assigned to send it. ( See each command. The response has two types; Command | | |... Bytes) | | |1|2|3| 4 |5|6| ~ | n | m | | 8 | 8 | 8 | 4 | 12 | 8 | ~ | 8 | 8 | | Bit | Bit | Bit |Bit| Bit | Bit | ~ | Bit | Bit | | | || | Data length Model code Projector ID ID2 ID1 * ID1: (8 Bit) This is done in a frame composed of PC 9 4. Acknowledge (hereafter referred to as ACK) that recognizes a command and Negative Acknowledge...
NP115 : RS232 codes- Projectors
Page 6
...model code from the following model codes is required. * Model code: (4 Bit) This is connected with multiple projectors To control a certain projector, use "individual notification". Response : This returns the 6th bit of individual notification or broadcast notification. for NAK ... . ( See each command. For all the projectors. (broadcast notification) This is connected with multiple projectors To control a certain projector, use "individual notification". Command : This specifies a projector ID for the projector that sends commands. (individual notification) Entering 0000B or...
...model code from the following model codes is required. * Model code: (4 Bit) This is connected with multiple projectors To control a certain projector, use "individual notification". Response : This returns the 6th bit of individual notification or broadcast notification. for NAK ... . ( See each command. For all the projectors. (broadcast notification) This is connected with multiple projectors To control a certain projector, use "individual notification". Command : This specifies a projector ID for the projector that sends commands. (individual notification) Entering 0000B or...
NP115 : RS232 codes- Projectors
Page 7
... 1111B : (broadcast notification) CAUTION : * When the model code is set to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is specified using total of 12 bits ( 0 - 4095) of 4 bits of the 4th byte and 8 bits of the 5th byte...the sum total of the header and data portions of data length specified in the data length portion. Response : This returns the model code for a projector received regardless of data portion (unit:: byte). Command : This sets data length of data added to a command to send it. ( See each ...
... 1111B : (broadcast notification) CAUTION : * When the model code is set to "broadcast notification", the command becomes broadcast notification command, regardless of values of the projector ID. * Model code is specified using total of 12 bits ( 0 - 4095) of 4 bits of the 4th byte and 8 bits of the 5th byte...the sum total of the header and data portions of data length specified in the data length portion. Response : This returns the model code for a projector received regardless of data portion (unit:: byte). Command : This sets data length of data added to a command to send it. ( See each ...
NP115 : RS232 codes- Projectors
Page 10
... STATUS REQUEST 079. INFORMATION REQUEST 037-1. LAMP INFORMATION REQUEST 4 038. GAIN PARAMETER REQUEST 2 077. FREEZE CONROL 097-198. PIP/SIDE BY SIDE REQUEST 098-196. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
... STATUS REQUEST 079. INFORMATION REQUEST 037-1. LAMP INFORMATION REQUEST 4 038. GAIN PARAMETER REQUEST 2 077. FREEZE CONROL 097-198. PIP/SIDE BY SIDE REQUEST 098-196. PROJECTOR INFORMATION REQUEST 00H 81H 00H 00H 00H 81H 00H C0H 00H 00H 00H C0H 00H 88H 00H 00H 00H 88H 02H 00H 00H 00H 00H...
NP115 : RS232 codes- Projectors
Page 12
... of an error. Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value of the lower 8 bits of the results calculated in byte units from all of response". (*5) Term "RGB" and "COMPUTER" On the HT1100, VT770, LT245/ LT265/ LT280/ LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W,... 50H 60H 70H D0H D0H D0H D0H 80H 90H (*3) Checksum: "CKS" inscription This is the value when forwarding a factory. This reflects the "Projector ID" that has been set to "COMPUTER". (*6) Term "DVI" and "COMPUTER" On the LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250...
... of an error. Command Descriptions Precautions with Inscriptions: (*1) Projector ID It is the value of the lower 8 bits of the results calculated in byte units from all of response". (*5) Term "RGB" and "COMPUTER" On the HT1100, VT770, LT245/ LT265/ LT280/ LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W,... 50H 60H 70H D0H D0H D0H D0H 80H 90H (*3) Checksum: "CKS" inscription This is the value when forwarding a factory. This reflects the "Projector ID" that has been set to "COMPUTER". (*6) Term "DVI" and "COMPUTER" On the LT380, NP1000/NP2000, NP1150/NP2150/NP3150/NP3151W, NP1250...
NP115 : RS232 codes- Projectors
Page 13
Command: 00H C0H 00H 00H 00H C0H Response: At the time of the projector. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of a success RUNNING SENSE Function: This command acquires the operation mode of ... = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of the projector. NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI connector" has been changed...
Command: 00H C0H 00H 00H 00H C0H Response: At the time of the projector. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of a success RUNNING SENSE Function: This command acquires the operation mode of ... = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of the projector. NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI connector" has been changed...
NP115 : RS232 codes- Projectors
Page 14
DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number...
DATA128 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Projector type See DATA70..71 08H : NP4000 Projector 11H : NP62 Projector DATA02 Projector ID DATA02 1 .. 64 NP4000 1 .. 254 NP62/NP64 1 .. 254 NP216 DATA03 Reserved DATA04 Projector status 00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number...
NP115 : RS232 codes- Projectors
Page 16
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
DATA66 Forced On-screen mute 00H : OFF 01H : ON DATA67 On-screen display 00H : No display 01H : Displaying DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71 Projector type
NP115 : RS232 codes- Projectors
Page 19
... The various bits are normal is "0" and error is "1". * "None" is "0" fixation. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector.
... The various bits are normal is "0" and error is "1". * "None" is "0" fixation. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector.
NP115 : RS232 codes- Projectors
Page 20
... OFF Function: This command switches off the main power of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off processing. (It contains a cooling period.) 018. POWER ON Function: This command switches on processing. 016. Command: 02H... of a success 22H 00H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the...
... OFF Function: This command switches off the main power of a failure A2H 01H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector doesn't accept the other command during power off processing. (It contains a cooling period.) 018. POWER ON Function: This command switches on processing. 016. Command: 02H... of a success 22H 00H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: The projector does not accept the other command during power on the main power of the...
NP115 : RS232 codes- Projectors
Page 27
...Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of Normal mode values. LAMP INFORMATION REQUEST Function: This command acquires the lamp information (in terms of use is also ...displayed with truncated a number after decimal point. 037-1. 037. INFORMATION REQUEST Function: This command acquires the projector information. DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 04 : Lamp Hour Meter(Normal mode) (second) It is displayed in terms...
...Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 5400000 seconds * The projector's hours of Normal mode values. LAMP INFORMATION REQUEST Function: This command acquires the lamp information (in terms of use is also ...displayed with truncated a number after decimal point. 037-1. 037. INFORMATION REQUEST Function: This command acquires the projector information. DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 04 : Lamp Hour Meter(Normal mode) (second) It is displayed in terms...
NP115 : RS232 codes- Projectors
Page 29
... DATA03 (00004650) 3) Change from HEX to 18000 seconds value will change to Decimal - 037-4. LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of lamp usage (in Eco mode. Command: 03H 96H 00H 00H 02H DATA01 DATA02...
... DATA03 (00004650) 3) Change from HEX to 18000 seconds value will change to Decimal - 037-4. LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in terms of Eco mode values) Response: At the time of lamp usage (in Eco mode. Command: 03H 96H 00H 00H 02H DATA01 DATA02...
NP115 : RS232 codes- Projectors
Page 30
...time until inhibition of lamp usage (in terms of Eco mode values) LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 ... of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. Lamp's use of hours = 18000/3600 = 5 hours...
...time until inhibition of lamp usage (in terms of Eco mode values) LAMP INFORMATION REQUEST 4 Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 ... of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is the lamp total usage. Lamp's use of hours = 18000/3600 = 5 hours...
NP115 : RS232 codes- Projectors
Page 31
... xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total...
... xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Setting Value 00H : Normal 01H : Eco Response: At the time of projector. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is the lamp total...
NP115 : RS232 codes- Projectors
Page 32
...02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. LAMP MODE SET Function: This command sets the lamp mode of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)... DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS...
...02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 07H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of projector. LAMP MODE SET Function: This command sets the lamp mode of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)... DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C3H fixed DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of projector. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of a failure A3H B0H 01H xxH 02H DATA01 DATA02 CKS...
NP115 : RS232 codes- Projectors
Page 33
... 00H 00H CKS Response: A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7. 049. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of projector.
... 00H 00H CKS Response: A2H 00H 01H 40H 02H DATA01 DATA02 CKS 7. 049. WXGA MODE SETTING SET Function: This command sets the WXGA Mode of projector.
NP115 : RS232 codes- Projectors
Page 34
REMOTE KEY CODE Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number DATA01 DATA02 Key ...
REMOTE KEY CODE Function: This command sends remote control key codes of projector. Command: 02H 0FH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 .. 02 : Remote control key code (Word type) Key number DATA01 DATA02 Key ...