PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 172
PRESCRIBE Command Reference MDAT - set MeDia type ATtribute Format MDAT [media-type[, paper-weight, fuser-mode, duplex[, density]]]; Parameters media-type 1 = Plain 2 = Transparency 3 = Preprinted 4 = Label 5 = Bond 6 = Recycled 7 = Vellum 8 = Rough 9 = Letterhead 10 = Color 11 = Prepunched 12 = Envelope 13 = Cardstock 14 = Coated ...
PRESCRIBE Command Reference MDAT - set MeDia type ATtribute Format MDAT [media-type[, paper-weight, fuser-mode, duplex[, density]]]; Parameters media-type 1 = Plain 2 = Transparency 3 = Preprinted 4 = Label 5 = Bond 6 = Recycled 7 = Vellum 8 = Rough 9 = Letterhead 10 = Color 11 = Prepunched 12 = Envelope 13 = Cardstock 14 = Coated ...
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 173
...= Medium Light 3 = Normal 4 = Medium Heavy 5 = Heavy Function The MDAT command is allowed for duplex printing or not. If the parameters paper-weight and fuser-mode are reset to customize the default attributes of a media type for the all media types are omitted, this command resets the three attributes back... to the thick paper weight and the high fuser temperature mode, disabling the duplex printing, command: !R! If all the parameter are omitted (MDAT;), all the attributes for optimization. MDAT 2, 1, 0,...
...= Medium Light 3 = Normal 4 = Medium Heavy 5 = Heavy Function The MDAT command is allowed for duplex printing or not. If the parameters paper-weight and fuser-mode are reset to customize the default attributes of a media type for the all media types are omitted, this command resets the three attributes back... to the thick paper weight and the high fuser temperature mode, disabling the duplex printing, command: !R! If all the parameter are omitted (MDAT;), all the attributes for optimization. MDAT 2, 1, 0,...
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 358
... Command Reference TATR - apply Tray ATtributes Format TATR [source[, thickness, print-density]]; This enables the printing system to optimize the electrical properties (such as the fuser temperature and the transfer bias) so that the best print quality is 3. TATR; TATR 0, 1, 3;
... Command Reference TATR - apply Tray ATtributes Format TATR [source[, thickness, print-density]]; This enables the printing system to optimize the electrical properties (such as the fuser temperature and the transfer bias) so that the best print quality is 3. TATR; TATR 0, 1, 3;
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 407
... priority, 116 font mode, 108, 119 saving current, 270 selection by assigning typeface, 294 Font attributes, 291 Font list, 105 printing a, 105 Font mode, 119 Fuser mode, 162, 163 G Graphics state, 228, 272 Gray pattern, 122 Grouping, 27 H Hard disk, 141, 246, 250, 256, 258 error codes, 136 I Image ...Job separation, 145 choosing first or all pages, 145 separating copies by command, 145 K KCGL pen color, 297 KIR, 304 refinement level, 304 KPDL, 287 Kyocera Image Refinement, 304 L left, 307 Lightness, 155 Line, 73, 80, 82, 87 drawing by angle, 82 drawing to absolute, 73 drawing to relative, 80...
... priority, 116 font mode, 108, 119 saving current, 270 selection by assigning typeface, 294 Font attributes, 291 Font list, 105 printing a, 105 Font mode, 119 Fuser mode, 162, 163 G Graphics state, 228, 272 Gray pattern, 122 Grouping, 27 H Hard disk, 141, 246, 250, 256, 258 error codes, 136 I Image ...Job separation, 145 choosing first or all pages, 145 separating copies by command, 145 K KCGL pen color, 297 KIR, 304 refinement level, 304 KPDL, 287 Kyocera Image Refinement, 304 L left, 307 Lightness, 155 Line, 73, 80, 82, 87 drawing by angle, 82 drawing to absolute, 73 drawing to relative, 80...
PRESCRIBE Commands Technical Reference Manual - Rev. 4.7
Page 105
... and PCL fonts Serial line control D0 0: XON is sent every 5 seconds during the printing system is valid. Interface-independent Parameters (Sheet 1 of page 0 1: Fuser sensor activated 2: Fuser sensor deactivated 3: Page ejection 4: Same as 0; Error is ignored. 1: XON is sent every 5 seconds during the 0 printing system is set automatically. 1: Does not automatically...
... and PCL fonts Serial line control D0 0: XON is sent every 5 seconds during the printing system is valid. Interface-independent Parameters (Sheet 1 of page 0 1: Fuser sensor activated 2: Fuser sensor deactivated 3: Page ejection 4: Same as 0; Error is ignored. 1: XON is sent every 5 seconds during the 0 printing system is set automatically. 1: Does not automatically...
PRESCRIBE Commands Technical Reference Manual - Rev. 4.7
Page 110
... is compatible with HP-LJ8000. 3: Combination of value 1 and 2. 8: Performs paper selection in increments of 7) Environment Paper type for 'Press GO' Automatic continue timer Quick fuser heater Parameter Value 8: Rough 9: Letterhead 10: Color 11: Prepunched 12: Envelope 13: Cardstock 21: Custom1 22: Custom2 23: Custom3 24: Custom4 25: Custom5 26: Custom6...
... is compatible with HP-LJ8000. 3: Combination of value 1 and 2. 8: Performs paper selection in increments of 7) Environment Paper type for 'Press GO' Automatic continue timer Quick fuser heater Parameter Value 8: Rough 9: Letterhead 10: Color 11: Prepunched 12: Envelope 13: Cardstock 21: Custom1 22: Custom2 23: Custom3 24: Custom4 25: Custom5 26: Custom6...