Installing Windows 7 Beta on HP Business Desktops
Page 2
...represents a list of requirements and HP Business Desktop models recommended for testing with WDDM driver and 128MB of memory o All models listed below have WDDM video drivers available 24 GB available hard disc space DVD-ROM drive HP recommends a 1.5GHz or faster CPU, 2GB of system memory (dual... is for UMA systems) and 80 GB 7200 RPM hard drive Applicable 2007 and prior models dc7700 dc7800 dc5700 dc5750 Applicable 2008 models dc7900 dc5800 dc5850 dx7400 dx7500 dx7510
...represents a list of requirements and HP Business Desktop models recommended for testing with WDDM driver and 128MB of memory o All models listed below have WDDM video drivers available 24 GB available hard disc space DVD-ROM drive HP recommends a 1.5GHz or faster CPU, 2GB of system memory (dual... is for UMA systems) and 80 GB 7200 RPM hard drive Applicable 2007 and prior models dc7700 dc7800 dc5700 dc5750 Applicable 2008 models dc7900 dc5800 dc5850 dx7400 dx7500 dx7510
Testing on HP Business Desktop PCs
Page 4
...feature set, subsystem (i.e., CPU, Memory, Graphics, Audio, PCI/PCIE, NIC, USB, IDE, LPC, etc.), and associated hardware components. 4 These tests include, but are not limited to: System Board Validation Testing This testing focuses on Business Desktop PCs to help ensure ... • Voltage Integrity Testing-This helps ensure that voltage regulators on the system board and in the power supply remain within HP Business Desktop specifications while running a variety of applications. For a given product configuration, hundreds of different software downloads, installations, and tests ...
...feature set, subsystem (i.e., CPU, Memory, Graphics, Audio, PCI/PCIE, NIC, USB, IDE, LPC, etc.), and associated hardware components. 4 These tests include, but are not limited to: System Board Validation Testing This testing focuses on Business Desktop PCs to help ensure ... • Voltage Integrity Testing-This helps ensure that voltage regulators on the system board and in the power supply remain within HP Business Desktop specifications while running a variety of applications. For a given product configuration, hundreds of different software downloads, installations, and tests ...
HP Disk Sanitizer, External Edition
Page 5
...drive. This is to ensure that the bootable USB drive key is to disconnect all internal and external (USB) drives will be erased. RAID Configuration HP Disk Sanitizer, External Edition supports RAID configuration. If two 80GB hard drives are used in mirrored mode (Raid 1), one 80GB hard drive will...the drive. In all other drives except the drive to be erased in the future, the CPU will be able to process and execute the application faster than 5GB. If you use RAID mode, HP recommends that you disconnect all cases, a small section of non-personal metadata used in mind...
...drive. This is to ensure that the bootable USB drive key is to disconnect all internal and external (USB) drives will be erased. RAID Configuration HP Disk Sanitizer, External Edition supports RAID configuration. If two 80GB hard drives are used in mirrored mode (Raid 1), one 80GB hard drive will...the drive. In all other drives except the drive to be erased in the future, the CPU will be able to process and execute the application faster than 5GB. If you use RAID mode, HP recommends that you disconnect all cases, a small section of non-personal metadata used in mind...
Desktop Management Guide
Page 12
... BitLocker support without user interaction) determines the revision levels of recovery emergencies. SSM then automatically updates any or all supported HP business desktop, notebook, and workstation models. Disable BitLocker via Group Policy in the file store. You can confidently and efficiently use SSM... Vista BitLocker enabled and are sent real-time when triggered by visiting http://www.hp.com/go /hpcmi/. System Software Manager integrates with enterprise software distribution tools such as CPU, memory, video, and security settings ● Monitor system health to fix problems...
... BitLocker support without user interaction) determines the revision levels of recovery emergencies. SSM then automatically updates any or all supported HP business desktop, notebook, and workstation models. Disable BitLocker via Group Policy in the file store. You can confidently and efficiently use SSM... Vista BitLocker enabled and are sent real-time when triggered by visiting http://www.hp.com/go /hpcmi/. System Software Manager integrates with enterprise software distribution tools such as CPU, memory, video, and security settings ● Monitor system health to fix problems...
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 32
... hardware issues in your installed base of HP client systems ■ Active Chat-connect to HP customer support to resolve issues 3-4 437804-001 Service Reference Guide, dc5700 Subscribe for a wide range of client hardware alerts (such as CPU, memory, video, and security settings ■...changing the BIOS passwords and computer boot order remotely from the system management console of device drivers and BIOS updates for supported HP business desktop, notebook, and workstation models. System Software Manager integrates with Altiris, is a free utility that automates remote deployment of ...
... hardware issues in your installed base of HP client systems ■ Active Chat-connect to HP customer support to resolve issues 3-4 437804-001 Service Reference Guide, dc5700 Subscribe for a wide range of client hardware alerts (such as CPU, memory, video, and security settings ■...changing the BIOS passwords and computer boot order remotely from the system management console of device drivers and BIOS updates for supported HP business desktop, notebook, and workstation models. System Software Manager integrates with Altiris, is a free utility that automates remote deployment of ...
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 64
...standby mode. ■ Before handling a drive, ensure that cables are placed in their proper location during the reassembly process. HP strongly recommends that all screws removed during disassembly be kept with care to their protective packaging until they cannot be caught or snagged... by the connector whenever possible. screws have magnetic fields such as monitors or speakers. 5-8 437804-001 Service Reference Guide, dc5700 Keep hard drives in the CPU. ■ Avoid dropping drives from the connector. They may have a black finish. These cables must be mailed, place ...
...standby mode. ■ Before handling a drive, ensure that cables are placed in their proper location during the reassembly process. HP strongly recommends that all screws removed during disassembly be kept with care to their protective packaging until they cannot be caught or snagged... by the connector whenever possible. screws have magnetic fields such as monitors or speakers. 5-8 437804-001 Service Reference Guide, dc5700 Keep hard drives in the CPU. ■ Avoid dropping drives from the connector. They may have a black finish. These cables must be mailed, place ...
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 75
Removal and Replacement Procedures- Cable To Cable Designator Power Supply System board P1 Power Supply CPU power P3 Power Supply 2nd SATA Hard drive P4 Power Supply 1st SATA Hard drive P5 Power Supply 1st Optical drive P7 Power Supply 2nd ... 3rd HDD if no ODD present System board P63, SATA 3 (Orange) Heatsink fan System board P70 Media Card Reader System board P150 Service Reference Guide, dc5700 437804-001 6-9 Microtower (MT) Chassis 6.6.1 Cable Connections System board connectors are color-coded to make it easier to find the proper connection.
Removal and Replacement Procedures- Cable To Cable Designator Power Supply System board P1 Power Supply CPU power P3 Power Supply 2nd SATA Hard drive P4 Power Supply 1st SATA Hard drive P5 Power Supply 1st Optical drive P7 Power Supply 2nd ... 3rd HDD if no ODD present System board P63, SATA 3 (Orange) Heatsink fan System board P70 Media Card Reader System board P150 Service Reference Guide, dc5700 437804-001 6-9 Microtower (MT) Chassis 6.6.1 Cable Connections System board connectors are color-coded to make it easier to find the proper connection.
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 111
... proper connection. Removal and Replacement Procedures- Cable To Cable Designator Power Supply Main power, P1 P1 Power Supply 1st SATA Hard drive P2 Power Supply CPU power P3 Power Supply 2nd SATA Hard drive P4 Power Supply SATA Optical drive P6 Power Supply Diskette drive P7 Power Supply SATA Optical drive... drive if no ODD System board P61, SATA1 (White) ODD if 2nd SATA Hard drive System board present P62, SATA4 (Light blue) Service Reference Guide, dc5700 437804-001 7-7
... proper connection. Removal and Replacement Procedures- Cable To Cable Designator Power Supply Main power, P1 P1 Power Supply 1st SATA Hard drive P2 Power Supply CPU power P3 Power Supply 2nd SATA Hard drive P4 Power Supply SATA Optical drive P6 Power Supply Diskette drive P7 Power Supply SATA Optical drive... drive if no ODD System board P61, SATA1 (White) ODD if 2nd SATA Hard drive System board present P62, SATA4 (Light blue) Service Reference Guide, dc5700 437804-001 7-7
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 146
Connector Pin Assignments 6-Pin Power (for CPU) Connector and Icon 4 6 Pin Signal 1 GND 2 GND 3 GND 4 12 V CPU 5 12 V CPU 6 +12 V SATA Data and Power Drive Connector Pin Signal Pin Signal S1 Ground S5 B- S2 A+ S6 B+ P1 V 3.3 P5 Ground P9 V 5 P13 V 12 P2 V 3.3 P6 Ground P10 Ground P14 V 12 *S = Data, P = Power Pin Signal S3 AS7 Ground P3 V 3.3 P7 V 5 P11 Reserved P15 V 12 Pin Signal S4 Ground P4 Ground P8 V 5 P12 Ground A-6 437804-001 Service Reference Guide, dc5700
Connector Pin Assignments 6-Pin Power (for CPU) Connector and Icon 4 6 Pin Signal 1 GND 2 GND 3 GND 4 12 V CPU 5 12 V CPU 6 +12 V SATA Data and Power Drive Connector Pin Signal Pin Signal S1 Ground S5 B- S2 A+ S6 B+ P1 V 3.3 P5 Ground P9 V 5 P13 V 12 P2 V 3.3 P6 Ground P10 Ground P14 V 12 *S = Data, P = Power Pin Signal S3 AS7 Ground P3 V 3.3 P7 V 5 P11 Reserved P15 V 12 Pin Signal S4 Ground P4 Ground P8 V 5 P12 Ground A-6 437804-001 Service Reference Guide, dc5700
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 156
...Device Failure External tape drive not connected. 611-Primary Floppy Port Address Assignment Conflict 660-Display cache is an issue. Replace the CPU fan. 1. Reseat chassis, rear chassis, or front chassis fan. 2. Replace diskette drive. 5. Disconnect any other diskette controller ...Reconnect or replace front audio harness. C-4 437804-001 Service Reference Guide, dc5700 Replace CPU or chassis fan. 1. Check and/or replace cables. 3. Reseat the CPU fan. 2. Reseat fan cable. 3. Reseat fan cable. 3. Reseat CPU or chassis fan. 2. Recommended Action 1. Clear CMOS. 4. No ...
...Device Failure External tape drive not connected. 611-Primary Floppy Port Address Assignment Conflict 660-Display cache is an issue. Replace the CPU fan. 1. Reseat chassis, rear chassis, or front chassis fan. 2. Replace diskette drive. 5. Disconnect any other diskette controller ...Reconnect or replace front audio harness. C-4 437804-001 Service Reference Guide, dc5700 Replace CPU or chassis fan. 1. Check and/or replace cables. 3. Reseat the CPU fan. 2. Reseat fan cable. 3. Reseat fan cable. 3. Reseat CPU or chassis fan. 2. Recommended Action 1. Clear CMOS. 4. No ...
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 159
... computer cover, press the power button, and see if the processor fan spins. Service Reference Guide, dc5700 437804-001 C-7 Ensure that none of the keys are depressed. 4. Parity Check 2 System will not boot without fan. CPU fan not installed or disconnected in and the heatsink is properly seated but the fan does...
... computer cover, press the power button, and see if the processor fan spins. Service Reference Guide, dc5700 437804-001 C-7 Ensure that none of the keys are depressed. 4. Parity Check 2 System will not boot without fan. CPU fan not installed or disconnected in and the heatsink is properly seated but the fan does...
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 206
... 12V header Secondary Processor 12V header Main Power/HDD LED connector Speaker connector Analog audio connector (from CD-ROM) Primary chassis fan header or primary CPU heatsink fan Secondary chassis fan header Diskette drive connector Auxiliary Audio connector Alert on LAN connector VRM module footprint AUI connector Fan command/fan sink... expansion header SPDIF internal input header SPDIF internal output header Primary IDE connector Secondary IDE/MultiBay connector Header for NEWCARD E-2 437804-001 Service Reference Guide, dc5700
... 12V header Secondary Processor 12V header Main Power/HDD LED connector Speaker connector Analog audio connector (from CD-ROM) Primary chassis fan header or primary CPU heatsink fan Secondary chassis fan header Diskette drive connector Auxiliary Audio connector Alert on LAN connector VRM module footprint AUI connector Fan command/fan sink... expansion header SPDIF internal input header SPDIF internal output header Primary IDE connector Secondary IDE/MultiBay connector Header for NEWCARD E-2 437804-001 Service Reference Guide, dc5700
HP Compaq dc5700 Business PC Service Reference Guide, 1st Edition
Page 207
... connector Fifth Serial ATA (SATA) connector Sixth Serial ATA (SATA) connector Seventh Serial ATA (SATA) connector Eighth Serial ATA (SATA) connector Primary (CPU) fan header for fansink Secondary CPU fan header for fansink Primary Serial Attached SCSI (SAS) connector Second Serial Attached SCSI (SAS) connector Third Serial Attached SCSI (SAS) connector Fourth... Security hood switch on riser card Clear CMOS switch/push button Single chip solution (combined northbridge/southbridge) North bridge South bridge Super I/O Service Reference Guide, dc5700 437804-001 E-3
... connector Fifth Serial ATA (SATA) connector Sixth Serial ATA (SATA) connector Seventh Serial ATA (SATA) connector Eighth Serial ATA (SATA) connector Primary (CPU) fan header for fansink Secondary CPU fan header for fansink Primary Serial Attached SCSI (SAS) connector Second Serial Attached SCSI (SAS) connector Third Serial Attached SCSI (SAS) connector Fourth... Security hood switch on riser card Clear CMOS switch/push button Single chip solution (combined northbridge/southbridge) North bridge South bridge Super I/O Service Reference Guide, dc5700 437804-001 E-3
HP Compaq dc5700 Microtower Business PC Illustrated Parts & Service Map, 2nd Edition
Page 2
...-5300, CL5 396519-001 * 512 MB, PC2-5300, CL5 396520-001 * 1 GB, PC2-5300, CL5 398038-001 System Boards with thermal grease, alcohol pad, and CPU socket cover 2 Standard board 404794-001 * Board without embedded security (EMEA only) 434369-001 Intel Celeron D Processors with alcohol pad and thermal grease * #352, 512K... height 414180-001 432863-001 432874-001 433123-001 435526-001 390937-001 390939-001 417966-001 390938-001 153099-001 430129-001 392414-001 dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 2
...-5300, CL5 396519-001 * 512 MB, PC2-5300, CL5 396520-001 * 1 GB, PC2-5300, CL5 398038-001 System Boards with thermal grease, alcohol pad, and CPU socket cover 2 Standard board 404794-001 * Board without embedded security (EMEA only) 434369-001 Intel Celeron D Processors with alcohol pad and thermal grease * #352, 512K... height 414180-001 432863-001 432874-001 433123-001 435526-001 390937-001 390939-001 417966-001 390938-001 153099-001 430129-001 392414-001 dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 2
HP Compaq dc5700 Microtower Business PC Illustrated Parts & Service Map, 2nd Edition
Page 3
... drive SW50 Clear CMOS P11 Aux audio XBT1 Real-time-clock battery P23 Front audio XMM1 DIMM 1 P24 Front USB XMM2 DIMM 2 P3 CPU power XMM3 DIMM 3 P5 Power button/LED XMM4 DIMM 4 P52 Flying serial port XU1 Processor P6 Internal speaker System Setup and Boot Basic ... X1 P8 Primary chassis fan (front) J41 PCIE X16 for PCI 12 Mouse 13 Coprocessor 14 Primary ATA (IDE) Controller 15 Secondary ATA (IDE) Controller dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 3 Save Changes and Exit - Lists all I /O APIC mode - Off/on - Allows you to...
... drive SW50 Clear CMOS P11 Aux audio XBT1 Real-time-clock battery P23 Front audio XMM1 DIMM 1 P24 Front USB XMM2 DIMM 2 P3 CPU power XMM3 DIMM 3 P5 Power button/LED XMM4 DIMM 4 P52 Flying serial port XU1 Processor P6 Internal speaker System Setup and Boot Basic ... X1 P8 Primary chassis fan (front) J41 PCIE X16 for PCI 12 Mouse 13 Coprocessor 14 Primary ATA (IDE) Controller 15 Secondary ATA (IDE) Controller dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 3 Save Changes and Exit - Lists all I /O APIC mode - Off/on - Allows you to...
HP Compaq dc5700 Microtower Business PC Illustrated Parts & Service Map, 2nd Edition
Page 4
...F10 when the monitor light turns green to fail. Remove the chassis access panel. 3. dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 4 As soon as the ...bypass the title screen, if necessary. 3. Enter the product number (for proper seating, type, and HP compatibility. 3. System board. 1. Check for firmware patch for 5 seconds. 4. Establishing a Setup ...Power Green 1 blink every 2 seconds Normal Suspend Mode Power Red 1 blink every second followed CPU thermal shutdown by a 2 second pause Power Red 3 blinks, 1 blink every second Processor not...
...F10 when the monitor light turns green to fail. Remove the chassis access panel. 3. dc5700 Illustrated Parts & Service Map, MT Chassis 439125-002 page 4 As soon as the ...bypass the title screen, if necessary. 3. Enter the product number (for proper seating, type, and HP compatibility. 3. System board. 1. Check for firmware patch for 5 seconds. 4. Establishing a Setup ...Power Green 1 blink every 2 seconds Normal Suspend Mode Power Red 1 blink every second followed CPU thermal shutdown by a 2 second pause Power Red 3 blinks, 1 blink every second Processor not...
Troubleshooting Guide
Page 58
... 2. Reflash the system ROM with computer turned off . 2. Reconnect the keyboard with the latest BIOS image. 511-CPU, CPUA, or CPUB Fan not Detected CPU fan is attached and turned on. 4. Clear CMOS. (See Appendix B, Password Security and Resetting CMOS on page 59...image has errors. Reconfigure card resources and/or run Computer Setup. 410-Audio Interrupt Conflict IRQ address conflicts with another device. Reseat CPU fan. 2. Remove any parallel port expansion to parallel port X. Replace keyboard. 303-Keyboard Controller Error I/O board keyboard controller. 1. ...
... 2. Reflash the system ROM with computer turned off . 2. Reconnect the keyboard with the latest BIOS image. 511-CPU, CPUA, or CPUB Fan not Detected CPU fan is attached and turned on. 4. Clear CMOS. (See Appendix B, Password Security and Resetting CMOS on page 59...image has errors. Reconfigure card resources and/or run Computer Setup. 410-Audio Interrupt Conflict IRQ address conflicts with another device. Reseat CPU fan. 2. Remove any parallel port expansion to parallel port X. Replace keyboard. 303-Keyboard Controller Error I/O board keyboard controller. 1. ...
Troubleshooting Guide
Page 59
...(See Appendix B, Password Security and Resetting CMOS on page 59.) 4. degrading is not connected or may have malfunctioned. 2. Replace CPU or chassis fan. 601-Diskette Controller Error Diskette controller circuitry or floppy drive circuitry incorrect. 1. unseated from motherboard. 918-Front USB ...Not Connected Front USB harness has been detached or unseated from motherboard. Reseat CPU or chassis fan. Run Computer Setup. 2. Replace the system board. 605-Diskette Drive Type Error Mismatch in the x16 ...
...(See Appendix B, Password Security and Resetting CMOS on page 59.) 4. degrading is not connected or may have malfunctioned. 2. Replace CPU or chassis fan. 601-Diskette Controller Error Diskette controller circuitry or floppy drive circuitry incorrect. 1. unseated from motherboard. 918-Front USB ...Not Connected Front USB harness has been detached or unseated from motherboard. Reseat CPU or chassis fan. Run Computer Setup. 2. Replace the system board. 605-Diskette Drive Type Error Mismatch in the x16 ...
Troubleshooting Guide
Page 61
... card may be causing a Remove third-party graphics card to proper version. 2. turned off. 2. Parity Check 2 Parity RAM failure. System will not boot without fan CPU fan not installed or disconnected in Computer Setup. Invalid Electronic Serial Number Electronic serial number is properly seated but the fan does not spin, then...
... card may be causing a Remove third-party graphics card to proper version. 2. turned off. 2. Parity Check 2 Parity RAM failure. System will not boot without fan CPU fan not installed or disconnected in Computer Setup. Invalid Electronic Serial Number Electronic serial number is properly seated but the fan does not spin, then...