Manual/User Guide - Page 5
... for
American National
Information Systems-Small Computer Standards Institute
System Interface - 2(SCSI-2)
(ANSI)
COMMON COMMAND SET (CCS) of products covered by this manual comply with the following standards. Related Standards
Specifications and functions of the Small Computer System Interface (SCSI)
American National Standards Institute (ANSI)
WORKING DRAFT Information Technology...
Manual/User Guide - Page 7
... of model names and product numbers, and SCSI interface functions.
The model numbers ... user does not perform the procedure correctly. CONVENTIONS This manual uses the following conventions for alerts to prevent physical or... setting terminals and connectors, a list of setting items, the signal assignments of interface connectors, lists of the SCSI interface between host system and disk drive,...
Manual/User Guide - Page 8
...name
Model name
MAH3182
MAH3182MC, MAH3182MP
MAH3091
MAH3091MC, MAH3091MP
MAJ3364
MAJ3364MC, MAJ3364MP
MAJ3182
MAJ3182MC, MAJ3182MP
MAJ3091
MAJ3091MC, MAJ3091MP
C141-E103-02EN
vii Fujitsu is not responsible for connecting the three device types or host system and the disk drives (Note 1). Hand Disk Drive
Type
AH: Number of rotations 7,200min-1 (7,200rpm) AJ: Number of the SCSI...
Manual/User Guide - Page 15
... (MAH series MC model A-2 A.2 Locations of Connectors and Setting Terminals (MAH series MP model A-3 A.3 Locations of Connectors and Setting Terminals (MAJ series MC model A-4 A.4 Locations of Connectors and Setting Terminals (MAJ series MP model A-5
APPENDIX B SETTING TERMINALS B-1 B.1 Setting Terminals ...B-2
APPENDIX C CONNECTOR SIGNAL ALLOCATION C-1 C.1 SCSI Connector Signal Allocation...
Manual/User Guide - Page 22
...segment data buffer
The data buffer is adopted to prevent a specific command from the data buffer without concerning the physical structure of .../output operations with utilizing high data transfer capability of the SCSI bus regardless of actual data transfer rate of the data...data to the data buffer or empty condition of the disk drive.
(7) Read-ahead cache feature
After executing the READ ...
Manual/User Guide - Page 26
...rotary voice coil motor (VCM), consumes little power and generates little heat. Each model contains following number of the actuator arm is started. The motor speed is controlled by a direct-drive hall-less DC motor.
C141-E103-02EN
1 - 7 Figure 1.5 shows the configuration of disks and heads
MAH3182 0 1 2 3
MAH3091
0 1
MAJ3364
0 1 2 3 4 5 6 7 8 9
MAJ3182
0 1 2 3 4
MAJ3091
0 1 2
Figure...
Manual/User Guide - Page 34
... trouble, cable failures, or other failures not caused by one retry should not exceed 10 per 108 seeks.
2.1.5 Reliability
(1) Mean Time Between Failures (MTBF)
MTBF of the equipment means failure that requires repair, adjustments, or replacement. Mishandling by the operator, failures due to be accessed should be distributed over the disk medium equally.
(1) Unrecoverable error...
Manual/User Guide - Page 82
... environment. CHAPTER 5 INSTALLATION
5.1 Notes on Handling Drives 5.2 Connections 5.3 Setting Terminals 5.4 Mounting Drives 5.5 Connecting Cables 5.6 Confirming Operations after Installation and Preparation
for Use 5.7 Dismounting Drives 5.8 Spare Disk Drive
This chapter describes the notes on Handling Drives
The items listed in the specifications in the drive, note the following...
Manual/User Guide - Page 87
Force Single Ended: LVD mode Force Narrow: 16bit-SCSI Spin-up mode Write protect: enabled SCSI ID #15 (MP model) # 0 (MC model)
2 4 6 8 10 12 14 16
1 3 5 7 9 11 13 15 MC model
Figure 5.3 Setting terminals (CN2)
5.3.1 SCSI ID setting Table 5.1 shows the SCSI ID setting. IMPORTANT When the SCSI ID is set using the external operator panel connector CN1, all pins listed in Table...
Manual/User Guide - Page 97
.... Refer to the terminating resistor. a. In this case, the number of SCSI Logical Interface Specifications for each model (part number) when shipped from the default format, all sides of data blocks" field.
c) Check the setting of cylinders in the format parameter (page code = 3) and drive parameter (page code = 4).
5 - 16
C141-E103-02EN
The user can be obtained with...
Manual/User Guide - Page 101
... the rough calculation values for further details. a. In a system without the disconnection function, these parameters need not be set. Refer to Chapter 2 of SCSI Logical Interface Specifications for how to evaluate the validity of the disk. It is recommended to be specified.
2.
Determine the parameter values in consideration of the following parameters are used...
Manual/User Guide - Page 103
... determined in an antistatic bag and provide packing (see Section 5.1).
5.8 Spare Disk Drive
See Appendix D, "Model Names and Product Numbers," to the system. d) Remove the DC ground cable. a) Remove the power cable. If it in consideration of the requirements specific to order a disk drive for replacement or as a spare
5 - 22
C141-E103-02EN
e) Remove the four mounting...
Manual/User Guide - Page 110
... to submit information for the disk drive. C141-E103-02EN
6 - 7 The DE cannot be replaced in the field. Fujitsu does not assume responsibility if data is destroyed during servicing or repair.
Generally, the following information must be included:
a) IDD model, part number (P/N), revision number, serial number (S/N), and date of manufacturing
b) Error status
• Date when the...
Manual/User Guide - Page 118
... returned to recur. This sense data makes the error type clear (functional, mechanical, or electrical error). Chapter 7 error analysis by troubleshooting, return the complete disk drive to the factory.
If the detected error cannot be recreated in the disk enclosure, return the whole disk drive to the factory for repair. Replace the disk drive, and check that the test method is correct...
Manual/User Guide - Page 123
...occurred inside IDD. • A drive error occurred. If this error occurs in different blocks, a PCA or DE is disk damage that was issued, or invalid or unsupported parameters were specified. • A SCSI interface error occurred. • A parity error occurred in a PCA or DE. The symptoms above , refer to the SCSI Logical Interface Specifications.
7 - 4
C141-E103-02EN For details...